Anatomical imaging for radiotherapy

The goal of radiation therapy is to achieve maximal therapeutic benefit expressed in terms of a high probability of local control of disease with minimal side effects. Physically this often equates to the delivery of a high dose of radiation to the tumour or target region whilst maintaining an acceptably low dose to other tissues, particularly those adjacent to the target. Techniques such as intensity modulated radiotherapy (IMRT), stereotactic radiosurgery and computer planned brachytherapy provide the means to calculate the radiation dose delivery to achieve the desired dose distribution. Imaging is an essential tool in all state of the art planning and delivery techniques: (i) to enable planning of the desired treatment, (ii) to verify the treatment is delivered as planned and (iii) to follow-up treatment outcome to monitor that the treatment has had the desired effect. Clinical imaging techniques can be loosely classified into anatomic methods which measure the basic physical characteristics of tissue such as their density and biological imaging techniques which measure functional characteristics such as metabolism. In this review we consider anatomical imaging techniques. Biological imaging is considered in another article. Anatomical imaging is generally used for goals (i) and (ii) above. Computed tomography (CT) has been the mainstay of anatomical treatment planning for many years, enabling some delineation of soft tissue as well as radiation attenuation estimation for dose prediction. Magnetic resonance imaging is fast becoming widespread alongside CT, enabling superior soft-tissue visualization. Traditionally scanning for treatment planning has relied on the use of a single snapshot scan. Recent years have seen the development of techniques such as 4D CT and adaptive radiotherapy (ART). In 4D CT raw data are encoded with phase information and reconstructed to yield a set of scans detailing motion through the breathing, or cardiac, cycle. In ART a set of scans is taken on different days. Both allow planning to account for variability intrinsic to the patient. Treatment verification has been carried out using a variety of technologies including: MV portal imaging, kV portal/fluoroscopy, MVCT, conebeam kVCT, ultrasound and optical surface imaging. The various methods have their pros and cons. The four x-ray methods involve an extra radiation dose to normal tissue. The portal methods may not generally be used to visualize soft tissue, consequently they are often used in conjunction with implanted fiducial markers. The two CT-based methods allow measurement of inter-fraction variation only. Ultrasound allows soft-tissue measurement with zero dose but requires skilled interpretation, and there is evidence of systematic differences between ultrasound and other data sources, perhaps due to the effects of the probe pressure. Optical imaging also involves zero dose but requires good correlation between the target and the external measurement and thus is often used in conjunction with an x-ray method. The use of anatomical imaging in radiotherapy allows treatment uncertainties to be determined. These include errors between the mean position at treatment and that at planning (the systematic error) and the day-to-day variation in treatment set-up (the random error). Positional variations may also be categorized in terms of inter- and intra-fraction errors. Various empirical treatment margin formulae and intervention approaches exist to determine the optimum strategies for treatment in the presence of these known errors. Other methods exist to try to minimize error margins drastically including the currently available breath-hold techniques and the tracking methods which are largely in development. This paper will review anatomical imaging techniques in radiotherapy and how they are used to boost the therapeutic benefit of the treatment.

[1]  J. E. O'Connor The variation of scattered x-rays with density in an irradiated body. , 1957, Physics in medicine and biology.

[2]  G. Hounsfield Computerized transverse axial scanning (tomography). 1. Description of system. , 1973, The British journal of radiology.

[3]  J Milan,et al.  The storage and manipulation of radiation dose data in a small digital computer. , 1974, The British journal of radiology.

[4]  THE USE OF COMPUTED TOMOGRAPHY DATA FOR RADIOTHERAPY DOSE CALCULATIONS , 1979, International journal of radiation oncology, biology, physics.

[5]  M R Sontag,et al.  The equivalent tissue-air ratio method for making absorbed dose calculations in a heterogeneous medium. , 1978, Radiology.

[6]  P. Kijewski,et al.  THE USE OF COMPUTED TOMOGRAPHY DATA FOR RADIOTHERAPY DOSE CALCULATIONS , 1978, International journal of radiation oncology, biology, physics.

[7]  R. P. Parker,et al.  The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media. , 1979 .

[8]  Victor J. Sank,et al.  THE DIRECT USE OF CT NUMBERS IN RADIOTHERAPY DOSAGE CALCULATIONS FOR INHOMOGENEOUS MEDIA , 1978, Physics in medicine and biology.

[9]  G. Chen,et al.  Treatment planning for heavy ion radiotherapy. , 1979, International journal of radiation oncology, biology, physics.

[10]  L. Axel Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. , 1980, Radiology.

[11]  R. P. Parker,et al.  The implementation of a generalised Batho inhomogeneity correction for radiotherapy planning with direct use of CT numbers. , 1981, Physics in medicine and biology.

[12]  W Swindell,et al.  A 4-MV CT scanner for radiation therapy: the prototype system. , 1982, Medical physics.

[13]  W Swindell A 4-MV CT scanner for radiation therapy; spectral properties of the therapy beam. , 1983, Medical physics.

[14]  D F Jackson,et al.  The relation between X-ray CT numbers and charged particle stopping powers and its significance for radiotherapy treatment planning. , 1983, Physics in medicine and biology.

[15]  Radiation medicine : medical imaging and radiation oncology , 1983 .

[16]  P. Henson,et al.  The electron density of bone for inhomogeneity correction in radiotherapy planning using CT numbers. , 1984, Physics in medicine and biology.

[17]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[18]  P J Biggs,et al.  A diagnostic X ray field verification device for a 10 MV linear accelerator. , 1984, International journal of radiation oncology, biology, physics.

[19]  M Dujovny,et al.  Multiplanar CT-guided stereotaxis and 125I interstitial radiotherapy. Image-guided tumor volume assessment, planning, dosimetric calculations, stereotactic biopsy and implantation of removable catheters. , 1987, Applied neurophysiology.

[20]  A Brahme,et al.  Radiotherapeutic computed tomography with scanned photon beams. , 1987, International journal of radiation oncology, biology, physics.

[21]  A. Brahme,et al.  Optimization of stationary and moving beam radiation therapy techniques. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  S. Webb Optimisation of conformal radiotherapy dose distributions by simulated annealing. , 1989, Physics in medicine and biology.

[23]  A. Ahnesjö Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. , 1989, Medical physics.

[24]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[25]  Y. Nagata,et al.  CT simulator: A new 3-D planning and simulating system for radiotherapy: Part 1. description of system , 1990 .

[26]  A dose distribution evaluation utilizing megavoltage CT imaging system. , 1990, Radiation medicine.

[27]  G W Sherouse,et al.  Computation of digitally reconstructed radiographs for use in radiotherapy treatment design. , 1990, International journal of radiation oncology, biology, physics.

[28]  Keiichi Nakagawa,et al.  DEVELOPMENT OF A MEGAVOLTAGE CT SCANNER USING LINEAR ACCELERATOR TREATMENT BEAM , 1991 .

[29]  A P Warrington,et al.  Relocatable frame for stereotactic external beam radiotherapy. , 1991, International journal of radiation oncology, biology, physics.

[30]  D. G. Lewis,et al.  A megavoltage CT scanner for radiotherapy verification. , 1992, Physics in medicine and biology.

[31]  D L McShan,et al.  A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[32]  M Coghe,et al.  Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  P. Munro,et al.  A review of electronic portal imaging devices (EPIDs). , 1992, Medical physics.

[34]  A Fenster,et al.  Daily monitoring and correction of radiation field placement using a video-based portal imaging system: a pilot study. , 1992, International journal of radiation oncology, biology, physics.

[35]  Blasko,et al.  Brachytherapy and Organ Preservation in the Management of Carcinoma of the Prostate. , 1993, Seminars in radiation oncology.

[36]  B Pickett,et al.  The role of the urethrogram during simulation for localized prostate cancer. , 1993, International journal of radiation oncology, biology, physics.

[37]  Steve Webb,et al.  The Physics of Three Dimensional Radiation Therapy , 1993 .

[38]  M van Herk,et al.  A verification procedure to improve patient set-up accuracy using portal images. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[39]  A Bel,et al.  Time trend of patient setup deviations during pelvic irradiation using electronic portal imaging. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[40]  A G Visser,et al.  Quality assurance using portal imaging: the accuracy of patient positioning in irradiation of breast cancer. , 1993, International journal of radiation oncology, biology, physics.

[41]  H. Kooy,et al.  Image fusion for stereotactic radiotherapy and radiosurgery treatment planning. , 1994, International journal of radiation oncology, biology, physics.

[42]  L. Marks,et al.  To treat or not to treat the internal mammary nodes: a possible compromise. , 1994, International journal of radiation oncology, biology, physics.

[43]  Jean-Claude Latombe,et al.  Image-Guided Robotic Radiosurgery , 1994, Modelling and Planning for Sensor Based Intelligent Robot Systems.

[44]  G. Hanks,et al.  Inaccuracies in using the lumpectomy scar for planning electron boosts in primary breast carcinoma. , 1994, International journal of radiation oncology, biology, physics.

[45]  Melvin L. Griem,et al.  Prescribing, Recording, and Reporting Photon Beam Therapy , 1994 .

[46]  D P Dearnaley,et al.  A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging system. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[47]  A. Brahme,et al.  A generalized pencil beam algorithm for optimization of radiation therapy. , 1994, Medical physics.

[48]  J. Blasko,et al.  Prostate specific antigen based disease control following ultrasound guided 125iodine implantation for stage T1/T2 prostatic carcinoma. , 1995, The Journal of urology.

[49]  D A Jaffray,et al.  Dual-beam imaging for online verification of radiotherapy field placement. , 1995, International journal of radiation oncology, biology, physics.

[50]  J. Crook,et al.  Prostate motion during standard radiotherapy as assessed by fiducial markers. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[51]  G. Hounsfield Computerized transverse axial scanning (tomography): Part I. Description of system. 1973. , 1973, The British journal of radiology.

[52]  1069 The use of ultrasonography in the localization of the lumpectomy cavity for low/high dose rate brachytherapy as the sole radiation modality in breast conserving therapy , 1995 .

[53]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[54]  M. Knopp,et al.  Effect of radiation on blood volume in low-grade astrocytomas and normal brain tissue: quantification with dynamic susceptibility contrast MR imaging. , 1996, AJR. American journal of roentgenology.

[55]  H. Hricak,et al.  Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three-dimensional conformal radiotherapy. , 1996, International journal of radiation oncology, biology, physics.

[56]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[57]  P M Evans,et al.  The application of transit dosimetry to precision radiotherapy. , 1996, Medical physics.

[58]  E. Pedroni,et al.  The calibration of CT Hounsfield units for radiotherapy treatment planning. , 1996, Physics in medicine and biology.

[59]  B R Paliwal,et al.  Modeling dose distributions from portal dose images using the convolution/superposition method. , 1996, Medical physics.

[60]  R. Stock,et al.  A new technique for performing Syed-Neblett template interstitial implants for gynecologic malignancies using transrectal-ultrasound guidance. , 1997, International journal of radiation oncology, biology, physics.

[61]  F. Vicini,et al.  The use of ultrasonography in the localization of the lumpectomy cavity for interstitial brachytherapy of the breast. , 1997, International journal of radiation oncology, biology, physics.

[62]  J Pouliot,et al.  Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study. , 1997, International journal of radiation oncology, biology, physics.

[63]  A W Beavis,et al.  Radiotherapy treatment planning of brain tumours using MRI alone. , 1998, The British journal of radiology.

[64]  S Webb,et al.  A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[65]  S. Webb,et al.  Rapid portal imaging with a high-efficiency, large field-of-view detector. , 1998, Medical physics.

[66]  C. Fiorino,et al.  Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[67]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[68]  J Wong,et al.  The use of adaptive radiation therapy to reduce setup error: a prospective clinical study. , 1998, International journal of radiation oncology, biology, physics.

[69]  B A Groh,et al.  Tomotherapeutic portal imaging for radiation treatment verification. , 1998, Physics in medicine and biology.

[70]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[71]  A. Brunt,et al.  Ultrasound localization of the ovaries for radiation-induced ovarian ablation. , 1999, Clinical oncology (Royal College of Radiologists (Great Britain)).

[72]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[73]  T. Mackie,et al.  Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.

[74]  W. Butler,et al.  Rectal dosimetric analysis following prostate brachytherapy. , 1999, International journal of radiation oncology, biology, physics.

[75]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[76]  A. Ahnesjö,et al.  Dose calculations for external photon beams in radiotherapy. , 1999, Physics in medicine and biology.

[77]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[78]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[79]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[80]  A study testing the routine use of ultrasound measurements when selecting the electron energy for breast boost radiotherapy. , 1999, Clinical oncology (Royal College of Radiologists (Great Britain)).

[81]  R Kozak,et al.  CT assessment of cerebral perfusion: experimental validation and initial clinical experience. , 1999, Radiology.

[82]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[83]  H Hansson,et al.  Verification of a pencil beam based treatment planning system: output factors for open photon beams shaped with MLC or blocks. , 1999, Physics in medicine and biology.

[84]  M van Herk,et al.  Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.

[85]  W Van den Bogaert,et al.  Tumoural perfusion as measured by dynamic computed tomography in head and neck carcinoma. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[86]  A G Visser,et al.  Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients. , 1999, International Journal of Radiation Oncology, Biology, Physics.

[87]  E Bellon,et al.  The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[88]  J. M. Taylor,et al.  Diffusion magnetic resonance imaging: an early surrogate marker of therapeutic efficacy in brain tumors. , 2000, Journal of the National Cancer Institute.

[89]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[90]  W. Manning,et al.  Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study. , 2000, International journal of radiation oncology, biology, physics.

[91]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[92]  M van Herk,et al.  The width of margins in radiotherapy treatment plans. , 2000, Physics in medicine and biology.

[93]  V S Khoo,et al.  A Comparison of clinical target volumes determined by CT and MRI for the radiotherapy planning of base of skull meningiomas. , 2000, International journal of radiation oncology, biology, physics.

[94]  T. Bortfeld,et al.  Direct measurement and analytical modeling of scatter in portal imaging. , 2000, Medical physics.

[95]  J Szanto,et al.  Respiratory-induced prostate motion: quantification and characterization. , 2000, International journal of radiation oncology, biology, physics.

[96]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[97]  S Webb,et al.  The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[98]  R. Pötter,et al.  Effect of distortions and asymmetry in MR images on radiotherapeutic treatment planning , 2000, International journal of cancer.

[99]  C. Becker,et al.  [Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT]. , 2000, Der Radiologe.

[100]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[101]  A G Visser,et al.  Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry. , 2000, Physics in medicine and biology.

[102]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[103]  J Wong,et al.  Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs. , 2000, International journal of radiation oncology, biology, physics.

[104]  D P Dearnaley,et al.  Radiotherapy planning of the pelvis using distortion corrected MR images: the removal of system distortions. , 2000, Physics in medicine and biology.

[105]  Dosimetry of 192Ir sources used for endovascular brachytherapy. , 2001, Physics in medicine and biology.

[106]  O Jäkel,et al.  Relation between carbon ion ranges and x-ray CT numbers. , 2001, Medical physics.

[107]  J Wong,et al.  Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[108]  Influence of a vac-fix immobilization device on the accuracy of patient positioning during routine breast radiotherapy. , 2001, The British journal of radiology.

[109]  Andrew H. Gee,et al.  Correction of Probe Pressure Artifacts in Freehand 3D Ultrasound , 2001, MICCAI.

[110]  S Mutic,et al.  A novel approach to overcome hypoxic tumor resistance: Cu-ATSM-guided intensity-modulated radiation therapy. , 2001, International journal of radiation oncology, biology, physics.

[111]  Optimization of conformal thoracic radiotherapy plans while using cone-beam CT imaging for treatment verification , 2001 .

[112]  S Senan,et al.  Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning. , 2001, International journal of radiation oncology, biology, physics.

[113]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[114]  O Jäkel,et al.  Treatment planning for heavy ion radiotherapy: clinical implementation and application. , 2001, Physics in medicine and biology.

[115]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[116]  B. Heijmen,et al.  A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. , 2001, International journal of radiation oncology, biology, physics.

[117]  D. Hill,et al.  Medical image registration , 2001, Physics in medicine and biology.

[118]  Rick Chappell,et al.  Is α/β for prostate tumors really low? , 2001 .

[119]  M. Lewis,et al.  Multislice CT: opportunities and challenges. , 2001, The British journal of radiology.

[120]  B. McCurdy,et al.  Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device. , 2001, Medical physics.

[121]  H Shirato,et al.  Magnetic resonance imaging system for three-dimensional conformal radiotherapy and its impact on gross tumor volume delineation of central nervous system tumors. , 2001, International journal of radiation oncology, biology, physics.

[122]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[123]  E Bellon,et al.  Interobserver variations in gross tumor volume delineation of brain tumors on computed tomography and impact of magnetic resonance imaging. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[124]  M W Vannier,et al.  Image-based dose planning of intracavitary brachytherapy: registration of serial-imaging studies using deformable anatomic templates. , 2001, International journal of radiation oncology, biology, physics.

[125]  N Pagoulatos,et al.  A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. , 2001, Ultrasound in medicine & biology.

[126]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[127]  P. Munro,et al.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58. , 2001, Medical physics.

[128]  Steve Webb,et al.  Intensity-Modulated Radiation Therapy , 1996, International journal of radiation oncology, biology, physics.

[129]  J. Kapatoes,et al.  On the accuracy and effectiveness of dose reconstruction for tomotherapy. , 2001, Physics in medicine and biology.

[130]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[131]  K. Langmack Review article: Portal imaging , 2001 .

[132]  M. Endo,et al.  Effect of scattered radiation on image noise in cone beam CT. , 2001, Medical physics.

[133]  P. Remeijer,et al.  Set-up verification using portal imaging; review of current clinical practice. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[134]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[135]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[136]  C. Ling,et al.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.

[137]  A. Boyer,et al.  An investigation of a video-based patient repositioning technique. , 2002, International journal of radiation oncology, biology, physics.

[138]  Andrew H. Gee,et al.  Correction of probe pressure artifacts in freehand 3D ultrasound , 2002, Medical Image Anal..

[139]  C C Ling,et al.  Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer. , 2002, Medical physics.

[140]  Glyn Johnson,et al.  Intracranial mass lesions: dynamic contrast-enhanced susceptibility-weighted echo-planar perfusion MR imaging. , 2002, Radiology.

[141]  Arjan Bel,et al.  Definition of gross tumor volume in lung cancer: inter-observer variability. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[142]  L. Antonuk Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research. , 2002, Physics in medicine and biology.

[143]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[144]  J A Rowlands,et al.  Development of high quantum efficiency flat panel detectors for portal imaging: intrinsic spatial resolution. , 2002, Medical physics.

[145]  Marcel van Herk,et al.  Margins for geometric uncertainty around organs at risk in radiotherapy. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[146]  Karl Rohr,et al.  Evaluation of 3D Operators for the Detection of Anatomical Point Landmarks in MR and CT Images , 2002, Comput. Vis. Image Underst..

[147]  Martin J Butson,et al.  Multilayer Gafchromic film detectors for breast skin dose determination in vivo. , 2002, Physics in medicine and biology.

[148]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[149]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[150]  H. Zeman,et al.  Theoretical analysis and experimental evaluation of a Csl(TI) based electronic portal imaging system. , 2002, Medical physics.

[151]  Hui Yan,et al.  A technique of intensity-modulated radiosurgery (IMRS) for spinal tumors. , 2002, Medical physics.

[152]  Martin J Murphy,et al.  Issues in respiratory motion compensation during external-beam radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[153]  Dirk Verellen,et al.  Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[154]  Richard Prager,et al.  Freehand 3D ultrasound without voxels: volume measurement and visualisation using the Stradx system. , 2002, Ultrasonics.

[155]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[156]  Hwa-Koon Wu,et al.  Nasopharyngeal carcinoma volume measurements determined with computed tomography: study of intraobserver and interobserver variability. , 2002, The Journal of otolaryngology.

[157]  P. Fransson,et al.  Prospective evaluation of urinary and intestinal side effects after BeamCath stereotactic dose-escalated radiotherapy of prostate cancer. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[158]  R. Wilks,et al.  The use of a compensator library to reduce dose inhomogeneity in tangential radiotherapy of the breast. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[159]  D. G. Lewis,et al.  Full forward Monte Carlo calculation of portal dose from MLC collimated treatment beams. , 2004, Physics in medicine and biology.

[160]  Michael B Sharpe,et al.  Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. , 2003, International journal of radiation oncology, biology, physics.

[161]  Lei Dong,et al.  Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins. , 2003, International journal of radiation oncology, biology, physics.

[162]  B G Fallone,et al.  Dosimetric IMRT verification with a flat-panel EPID. , 2003, Medical physics.

[163]  Eric C Ford,et al.  Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification. , 2003, International journal of radiation oncology, biology, physics.

[164]  Frank Van den Heuvel,et al.  Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers. , 2003, Medical physics.

[165]  Mark Ruschin,et al.  Digital fluoroscopy to quantify lung tumor motion: potential for patient-specific planning target volumes. , 2003, International journal of radiation oncology, biology, physics.

[166]  Radhe Mohan,et al.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. , 2003, Medical physics.

[167]  K. Miles,et al.  Perfusion CT: a worthwhile enhancement? , 2003, The British journal of radiology.

[168]  C Coolens,et al.  Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale. , 2003, Physics in medicine and biology.

[169]  A. Jackson,et al.  Cerebral perfusion imaging using contrast-enhanced MRI. , 2003, Clinical radiology.

[170]  Philippe Lambin,et al.  Tumor perfusion rate determined noninvasively by dynamic computed tomography predicts outcome in head-and-neck cancer after radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[171]  Y. Ung,et al.  Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC). , 2003, International journal of radiation oncology, biology, physics.

[172]  Ellen Yorke,et al.  Respiratory gating for liver tumors: use in dose escalation. , 2001, International journal of radiation oncology, biology, physics.

[173]  Frank Verhaegen,et al.  Monte Carlo modelling of external radiotherapy photon beams. , 2003, Physics in medicine and biology.

[174]  Thomas Krauss,et al.  Conformal radiotherapy planning of cervix carcinoma: differences in the delineation of the clinical target volume. A comparison between gynaecologic and radiation oncologists. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[175]  Aaron Fenster,et al.  Prostate boundary segmentation from 3D ultrasound images. , 2003, Medical physics.

[176]  Carlo Tognina,et al.  Megavoltage cone-beam computed tomography using a high-efficiency image receptor. , 2003, International journal of radiation oncology, biology, physics.

[177]  Francis Lilley,et al.  Opto-electronic sensing of body surface topology changes during radiotherapy for rectal cancer. , 2003, International journal of radiation oncology, biology, physics.

[178]  Jun Duan,et al.  Validation of target volume and position in respiratory gated CT planning and treatment. , 2003, Medical physics.

[179]  Aaron Fenster,et al.  Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound images. , 2003, Medical physics.

[180]  Kenneth G A Gilhuijs,et al.  Application of video imaging for improvement of patient set-up. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[181]  Lei Dong,et al.  Experience of ultrasound-based daily prostate localization. , 2003, International journal of radiation oncology, biology, physics.

[182]  Aaron Fenster,et al.  Testing and optimization of a semiautomatic prostate boundary segmentation algorithm using virtual operators. , 2003, Medical physics.

[183]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[184]  Jan J W Lagendijk,et al.  Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[185]  Steve Webb,et al.  Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[186]  Wilfred Sewchand,et al.  Marker seed migration in prostate localization. , 2002, International journal of radiation oncology, biology, physics.

[187]  K. Hayashi,et al.  Discrimination of metastatic cervical lymph nodes with diffusion-weighted MR imaging in patients with head and neck cancer. , 2003, AJNR. American journal of neuroradiology.

[188]  Graham M. Treece,et al.  High-definition freehand 3-D ultrasound. , 2003, Ultrasound in medicine & biology.

[189]  Hiroshi Onishi,et al.  A new irradiation unit constructed of self-moving gantry-CT and linac. , 2003, International journal of radiation oncology, biology, physics.

[190]  J Pouliot,et al.  Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID. , 2003, Medical physics.

[191]  J. Pouliot,et al.  Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[192]  J. Heiken,et al.  Detection of primary hepatic malignancy in liver transplant candidates: prospective comparison of CT, MR imaging, US, and PET. , 2003, Radiology.

[193]  Quynh-Thu Le,et al.  Patterns of patient movement during frameless image-guided radiosurgery. , 2003, International journal of radiation oncology, biology, physics.

[194]  Frieda Trichter,et al.  Prostate localization using transabdominal ultrasound imaging. , 2003, International journal of radiation oncology, biology, physics.

[195]  Alexander F. Kolen,et al.  Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo. , 2004, Physics in medicine and biology.

[196]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[197]  Olivier Rouvière,et al.  Recurrent prostate cancer after external beam radiotherapy: value of contrast-enhanced dynamic MRI in localizing intraprostatic tumor--correlation with biopsy findings. , 2004, Urology.

[198]  David A Jaffray,et al.  Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement. , 2004, International journal of radiation oncology, biology, physics.

[199]  John P McGahan,et al.  Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[200]  Richard Pötter,et al.  Effects of geometric distortion in 0.2T MRI on radiotherapy treatment planning of prostate cancer. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[201]  R. Mohan,et al.  Monte Carlo computation of dosimetric amorphous silicon electronic portal images. , 2004, Medical physics.

[202]  Joachim Mühling,et al.  Markerless laser registration in image-guided oral and maxillofacial surgery. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[203]  A. Svindland,et al.  Dynamic first pass 3D EPI of the prostate: accuracy in tumor location , 2004, Acta radiologica.

[204]  Deming Wang,et al.  A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging. , 2004, Magnetic resonance imaging.

[205]  M. Herk Errors and margins in radiotherapy. , 2004 .

[206]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[207]  Masahiro Hiraoka,et al.  A technique for noninvasive respiratory gated radiation treatment system based on a real time 3D ultrasound image correlation: a phantom study. , 2004, Medical physics.

[208]  E. Yorke,et al.  Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. , 2004, Seminars in radiation oncology.

[209]  R. Ramani,et al.  Delineation of brain metastases on CT images for planning radiosurgery: concerns regarding accuracy. , 2004, The British journal of radiology.

[210]  A N T J Kotte,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field. , 2004, Physics in medicine and biology.

[211]  Shinichi Shimizu,et al.  Intrafractional tumor motion: lung and liver. , 2004, Seminars in radiation oncology.

[212]  D. Oksuz,et al.  Tandem application with transvaginal ultrasound guidance. , 2004, International journal of radiation oncology, biology, physics.

[213]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors , 2004, Physics in medicine and biology.

[214]  Peter Mansfield,et al.  Snapshot magnetic resonance imaging (Nobel lecture). , 2004, Angewandte Chemie.

[215]  J J Sonke,et al.  Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. , 2003, Medical physics.

[216]  Tom Depuydt,et al.  The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[217]  Hiroki Shirato,et al.  Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy. , 2004, International journal of radiation oncology, biology, physics.

[218]  André Wambersie,et al.  The International Commission on Radiation Units and Measurements , 2001, Journal of the ICRU.

[219]  Hazim Jaradat,et al.  The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes. , 2004, International journal of radiation oncology, biology, physics.

[220]  D. Jaffray,et al.  The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors. , 2004, Medical physics.

[221]  T. Guerrero,et al.  Acquiring 4D thoracic CT scans using a multislice helical method. , 2004, Physics in medicine and biology.

[222]  Deming Wang,et al.  Geometric distortion in clinical MRI systems Part II: correction using a 3D phantom. , 2004, Magnetic resonance imaging.

[223]  Deming Wang,et al.  Geometric distortion in clinical MRI systems Part I: evaluation using a 3D phantom. , 2004, Magnetic resonance imaging.

[224]  M. Herman Clinical use of electronic portal imaging. , 2005, Seminars in radiation oncology.

[225]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[226]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[227]  Michael Sandborg,et al.  Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function. , 2005, Radiation protection dosimetry.

[228]  Qihua Zhao,et al.  Segmented phosphors: MEMS-based high quantum efficiency detectors for megavoltage x-ray imaging. , 2005, Medical physics.

[229]  J. Dempsey,et al.  Novel breathing motion model for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[230]  G H Olivera,et al.  The use of megavoltage CT (MVCT) images for dose recomputations , 2005, Physics in medicine and biology.

[231]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[232]  D. Georg,et al.  Dose-response characteristics of an amorphous silicon EPID , 2005 .

[233]  Fang-Fang Yin,et al.  A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification. , 2005, Medical physics.

[234]  Patrick A Kupelian,et al.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. , 2005, Medical physics.

[235]  David A Jaffray,et al.  Emergent technologies for 3-dimensional image-guided radiation delivery. , 2005, Seminars in radiation oncology.

[236]  Peter B Greer,et al.  Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry. , 2005, Medical physics.

[237]  John Wong,et al.  Accuracy of a wireless localization system for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[238]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[239]  Christopher J Moore,et al.  A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[240]  D. Georg,et al.  Dose-response characteristics of an amorphous silicon EPID. , 2005, Medical physics.

[241]  Margrit Betke,et al.  The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. , 2003, International journal of radiation oncology, biology, physics.

[242]  Branislav Jeremic,et al.  Positron Emission Tomography for Radiation Treatment Planning , 2005, Strahlentherapie und Onkologie.

[243]  C C Ling,et al.  Developments in megavoltage cone beam CT with an amorphous silicon EPID: reduction of exposure and synchronization with respiratory gating. , 2005, Medical physics.

[244]  Roger Owen,et al.  Fractionation sensitivity and dose response of late adverse effects in the breast after radiotherapy for early breast cancer: long-term results of a randomised trial. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[245]  Heinz Deutschmann,et al.  Radiotherapy planning for lung cancer: slow CTs allow the drawing of tighter margins. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[246]  Alicia Y Toledano,et al.  Interobserver reliability of computed tomography‐derived primary tumor volume measurement in patients with supraglottic carcinoma , 2005, Cancer.

[247]  M. Oldham,et al.  Cone-beam-CT guided radiation therapy: technical implementation. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[248]  M A Ebert,et al.  Volumetric uncertainty in radiotherapy. , 2005, Clinical oncology (Royal College of Radiologists (Great Britain)).

[249]  F. Verhaegen,et al.  Sensitivity study for CT image use in Monte Carlo treatment planning , 2005, Physics in medicine and biology.

[250]  S Webb,et al.  The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique , 2005, Physics in medicine and biology.

[251]  S Webb,et al.  Feasibility of using ultrasound for real-time tracking during radiotherapy. , 2005, Medical physics.

[252]  M van Herk,et al.  Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans , 2005, Physics in medicine and biology.

[253]  Peter Remeijer,et al.  Adaptive radiotherapy for invasive bladder cancer: a feasibility study. , 2005, International journal of radiation oncology, biology, physics.

[254]  S Webb,et al.  IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view , 2006, Physics in medicine and biology.

[255]  Suresh Senan,et al.  Evaluating mobility for radiotherapy planning of lung tumors: a comparison of virtual fluoroscopy and 4DCT. , 2006, Lung cancer.

[256]  A G Glendinning,et al.  Developments in electronic portal imaging systems. , 2006, The British journal of radiology.

[257]  Steve B. Jiang Radiotherapy of mobile tumors. , 2006, Seminars in radiation oncology.

[258]  Optimisation of radiation dose to patients in computed tomography , 2006 .

[259]  Joao Seco,et al.  Monte Carlo modelling of a-Si EPID response: the effect of spectral variations with field size and position. , 2006, Medical physics.

[260]  C. Ma,et al.  In-room CT techniques for image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[261]  P. Evans,et al.  Effects of averaging over motion and the resulting systematic errors in radiation therapy , 2006, Physics in medicine and biology.

[262]  M. V. van Herk,et al.  Anatomy changes in radiotherapy detected using portal imaging. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[263]  L. Xing,et al.  Image interpolation in 4D CT using a BSpline deformable registration model. , 2006, International journal of radiation oncology, biology, physics.

[264]  P. Evans,et al.  Monte Carlo and Lambertian light guide models of the light output from scintillation crystals at megavoltage energies. , 2006, Medical physics.

[265]  Peter Munro,et al.  A quality assurance program for the on-board imager®. , 2006, Medical physics.

[266]  Joao Seco,et al.  The susceptibility of IMRT dose distributions to intrafraction organ motion: an investigation into smoothing filters derived from four dimensional computed tomography data. , 2006, Medical physics.

[267]  P M Evans,et al.  Assessing the effect of electron density in photon dose calculations. , 2006, Medical physics.

[268]  John T. Wei,et al.  Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. , 2006, International journal of radiation oncology, biology, physics.

[269]  Fang-Fang Yin,et al.  Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning. , 2006, International journal of radiation oncology, biology, physics.

[270]  M. V. van Herk,et al.  Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method. , 2006, Medical physics.

[271]  I. Barillot,et al.  Clinical assessment of the use of the Sonarray system for daily prostate localization. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[272]  K. Ahn,et al.  Influence of intravenous contrast agent on dose calculations of intensity modulated radiation therapy plans for head and neck cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[273]  Jan-Jakob Sonke,et al.  Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. , 2006, International journal of radiation oncology, biology, physics.

[274]  Frank Verhaegen,et al.  Ultrasound-based image guided radiotherapy for prostate cancer: comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[275]  Lothar Spies,et al.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. , 2006, Medical physics.

[276]  James Wylie,et al.  X-ray volume imaging in bladder radiotherapy verification. , 2006, International journal of radiation oncology, biology, physics.

[277]  W. Kalender X-ray computed tomography , 2006, Physics in medicine and biology.

[278]  Gregory C Sharp,et al.  Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[279]  Weiguo Lu,et al.  Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy , 2006, Physics in medicine and biology.

[280]  M O Leach,et al.  Applications of magnetic resonance spectroscopy in radiotherapy treatment planning. , 2006, The British journal of radiology.

[281]  D. Low,et al.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. , 2006, Medical physics.

[282]  Eike Rietzel,et al.  Design of 4D treatment planning target volumes. , 2006, International journal of radiation oncology, biology, physics.

[283]  P. Hoskin,et al.  Innovative technologies in radiation therapy: brachytherapy. , 2006, Seminars in radiation oncology.

[284]  V S Khoo,et al.  New developments in MRI for target volume delineation in radiotherapy. , 2006, The British journal of radiology.

[285]  David A Jaffray,et al.  Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. , 2006, Medical physics.

[286]  Frank Verhaegen,et al.  Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations. , 2006, Medical physics.

[287]  Joao Seco,et al.  The susceptibility of IMRT dose distributions to intrafraction organ motion: An investigation into smoothing filters derived from four dimensional computed tomography data. , 2006, Medical physics.

[288]  TU-D-L100J-03: Initial Phantom Evaluation of a Surface Imaging System (GateCT®) for 4-D CT , 2007 .

[289]  S Webb,et al.  Tracking 'differential organ motion' with a 'breathing' multileaf collimator: magnitude of problem assessed using 4D CT data and a motion-compensation strategy. , 2007, Physics in medicine and biology.

[290]  Benjamin Movsas,et al.  A technique of quantitatively monitoring both respiratory and nonrespiratory motion in patients using external body markers. , 2007, Medical physics.

[291]  R. Orecchia,et al.  Intraoperative radiotherapy for locally advanced prostate cancer: treatment technique and ultrasound-based analysis of dose distribution. , 2007, Anticancer research.

[292]  Lei Xing,et al.  Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework , 2007, Physics in medicine and biology.

[293]  G. Ding,et al.  Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy , 2007, Physics in medicine and biology.

[294]  Follicular lymphoma, immunocytoma,and mantle cell lymphoma: Randomized evaluation of curative radiotherapy in limited stage nodal disease , 2007 .

[295]  T. Marchant,et al.  Imaging doses from the Elekta Synergy X-ray cone beam CT system. , 2007, The British journal of radiology.

[296]  D. Dearnaley,et al.  Distortion-corrected T2 weighted MRI: a novel approach to prostate radiotherapy planning. , 2007, The British journal of radiology.

[297]  M. Tomsej,et al.  Monte Carlo treatment planning for photon and electron beams , 2007 .

[298]  TU‐D‐M100J‐01: The Great Debate: The Future of IGRT Is…Megavolt CT…Kilovoltage CT…Ultrasound‐Based Hybrids…MRI Guidance…3D Deformable Image Registration , 2007 .

[299]  Jason P Fine,et al.  Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging 1 , 2007 .

[300]  B. Heijmen,et al.  eNAL: an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements. , 2007, International journal of radiation oncology, biology, physics.

[301]  D. Grignon,et al.  Results of a phase II trial of transrectal ultrasound-guided permanent radioactive implantation of the prostate for definitive management of localized adenocarcinoma of the prostate (radiation therapy oncology group 98-05). , 2007, International journal of radiation oncology, biology, physics.

[302]  Jean Pouliot,et al.  Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking. , 2007, International journal of radiation oncology, biology, physics.

[303]  Richard W Prager,et al.  High definition three-dimensional ultrasound to localise the tumour bed: a breast radiotherapy planning study. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[304]  Timothy Solberg,et al.  Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[305]  H Paganetti,et al.  Effects of organ motion on IMRT treatments with segments of few monitor units. , 2007, Medical physics.

[306]  D. Jaffray,et al.  Cone beam computed tomography guidance for setup of patients receiving accelerated partial breast irradiation. , 2007, International journal of radiation oncology, biology, physics.

[307]  W. Schlegel,et al.  Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax , 2007, Physics in medicine and biology.

[308]  Preliminary Results of a Comparison between High-tech External Beam and High-tech Brachytherapy for Cervix Carcinoma , 2007, Strahlentherapie und Onkologie.

[309]  Ping Xia,et al.  Dose calculation using megavoltage cone-beam CT. , 2007, International journal of radiation oncology, biology, physics.

[310]  Oliver Jäkel,et al.  The influence of metal artefacts on the range of ion beams , 2007, Physics in medicine and biology.

[311]  S. Goldberg,et al.  CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model. , 2007, Radiology.

[312]  Hiroki Shirato,et al.  Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. , 2007, Medical physics.

[313]  David A Jaffray,et al.  Image-guided radiation therapy: from concept to practice. , 2007, Seminars in Radiation Oncology.

[314]  David A Jaffray,et al.  Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. , 2007, International journal of radiation oncology, biology, physics.

[315]  W. Sause,et al.  Intensity-modulated radiotherapy using implanted fiducial markers with daily portal imaging: assessment of prostate organ motion. , 2007, International journal of radiation oncology, biology, physics.

[316]  Lei Dong,et al.  Reducing metal artifacts in cone-beam CT images by preprocessing projection data. , 2007, International journal of radiation oncology, biology, physics.

[317]  J. Aslam,et al.  Derivation of the tumor position from external respiratory surrogates with periodical updating of the internal/external correlation , 2007, Physics in medicine and biology.

[318]  S Webb,et al.  Adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion , 2008, Physics in medicine and biology.

[319]  Ursula Nestle,et al.  Biological imaging in radiation therapy: role of positron emission tomography , 2009, Physics in medicine and biology.

[320]  Balraj Naren,et al.  Medical Image Registration , 2022 .