Electrophoretic Deposition of Hydroxyapatite Coatings and Corrosion Aspects of Metallic Implants

Metallic materials such as stainless steels, cobalt-chromium alloys, titanium and its alloys, have been used extensively for centuries in restoration of anatomical structures due to their superior mechanical properties. The most important considerations for their selection in the human body are their biocompatibility, corrosion resistance, tissue reactions, surface conditions, and osseointegration (a bone bed formed through direct attachment to bone). Metallic implants are unique in that they are exposed to living cells, tissues and biological fluids, which are not only dynamic but also form a hostile environment for the implant. Clinical experience has shown that metallic implants are susceptible to localized corrosion in the human body, releasing metal ions into the surrounding tissues. Numerous failures of such implants have led to the application of biocompatible and corrosion resistant coatings, as well as to surface modification of the alloys. Ceramic materials that are based on hydroxyapatite (HAP), the principal constituent of dentine, bone and other hard tissues, are considered promising for osteo-implants and as a means of aiding the regeneration of bone. There are indications that chemical bonding may occur between HAP and bone. However, the poor mechanical properties of HAP limit its use in implantation. Bioceramic coatings have been intensively studied in order to obtain implant materials which have both biological affinity and high mechanical strength. This article reviews various aspects of corrosion resistance and biocompatibility of metallic implants. Surface modification of metallic materials by electrophoretic deposition (EPD) of HAP and the corrosion performance of these coatings in simulated body fluid conditions are also discussed.

[1]  S. Rajeswari,et al.  Investigation of failures in stainless steel orthopaedic implant device , 1994 .

[2]  P. Klopper,et al.  Tissue response to dense apatite implants in rats. , 1980, Journal of biomedical materials research.

[3]  D H COLLINS,et al.  Structural changes around nails and screws in human bones. , 1953, The Journal of pathology and bacteriology.

[4]  Michael Jarcho,et al.  Calcium phosphate ceramics as hard tissue prosthetics. , 1981, Clinical orthopaedics and related research.

[5]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[6]  P. Ducheyne,et al.  Structural analysis of hydroxyapatite coatings on titanium. , 1986, Biomaterials.

[7]  A. Ruys,et al.  Solution ripening of hydroxyapatite nanoparticles: effects on electrophoretic deposition. , 1999, Journal of biomedical materials research.

[8]  B. Moudgil,et al.  Electrophoretic deposition of calcium phosphates from non-aqueous media , 1993 .

[9]  M. C. García-Alonso,et al.  Comparative study of the corrosion behavior of MA-956 and conventional metallic biomaterials. , 1996, Journal of biomedical materials research.

[10]  Yoshiyuki Yokogawa,et al.  Hydroxyapatite implantation on the surface of pure titanium for orthopedic implants , 2000 .

[11]  T. Sridhar,et al.  Electrochemical behaviour of hydroxyapatite-coated stainless steel implants , 1997 .

[12]  P J Gregson,et al.  Application of PVD TiN coating to Co-Cr-Mo based surgical implants. , 1987, Biomaterials.

[13]  D. Williams,et al.  Advanced applications for materials implanted within the human body , 1987 .

[14]  P Ducheyne,et al.  Calcium phosphate ceramic coatings on porous titanium: effect of structure and composition on electrophoretic deposition, vacuum sintering and in vitro dissolution. , 1990, Biomaterials.

[15]  E. M. Pugatch The growth of endothelium and pseudoendothelium on the healing surface of rabbit ear chambers , 1964, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[16]  A. Ferguson,et al.  Tissue reaction in rabbit muscle exposed to metallic implants. , 1967, Journal of biomedical materials research.

[17]  T. Hanawa,et al.  Microdissolution of calcium ions from calciumion-implanted titanium , 1996 .

[18]  S. Rajeswari,et al.  Investigation of failures in stainless steel orthopaedic implant devices: pit-induced fatigue cracks , 1995 .

[19]  D. Zaffe,et al.  In vivo behavior of a high performance duplex stainless steel. , 1993, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[20]  M. Barbosa,et al.  Electrochemistry of AISI 316L stainless steel in calcium phosphate and protein solutions , 1991 .

[21]  C. Wright,et al.  Handbook of biomaterials evaluation: Scientific, technical, and clinical testing of implant materials , 1987 .

[22]  M. Davies,et al.  Modifications in the molecular structure of hydroxyapatite induced by titanium ions , 1995 .

[23]  D. Howie,et al.  The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles. , 1993, The Journal of bone and joint surgery. American volume.

[24]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[25]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[26]  P. Sarkar,et al.  Electrophoretic Deposition (EPD): Mechanisms, Kinetics, and Application to Ceramics , 1996 .

[27]  G. Gnappi,et al.  Sol-gel derived hydroxyapatite coatings on titanium substrate , 2000 .

[28]  M. Walt,et al.  Bone apposition to plasma-sprayed cobalt-chromium alloy. , 1992, Journal of biomedical materials research.

[29]  S. Rajeswari,et al.  Failures in stainless steel orthopaedic implant devices: A survey , 1995 .

[30]  J. Oldfield Test techniques for pitting and crevice corrosion resistance of stainless steels and nickel-base alloys in chloride-containing environments , 1987 .

[31]  J. Rieu Ceramic formation on metallic surfaces (ceramization) for medical applications. , 1993, Clinical materials.

[32]  U. Kamachi Mudali,et al.  Improvements in Localized Corrosion Resistance of Nitrogen Ion Implanted Type 316L Stainless Steel Orthopaedic Implant Devices , 1999 .

[33]  J F Osborn,et al.  [Biological behavior of the hydroxyapatite ceramic coating on the femur shaft of a titanium endoprosthesis--initial histologic evaluation of a human explant]. , 1987, Biomedizinische Technik. Biomedical engineering.

[34]  M. Bohmer In Situ Observation of 2-Dimensional Clustering during Electrophoretic Deposition , 1996 .

[35]  T. Nieh,et al.  Preparing hydroxyapatite powders with controlled morphology. , 1996, Biomaterials.

[36]  I. Zhitomirsky,et al.  Electrophoretic deposition of hydroxyapatite , 1997, Journal of materials science. Materials in medicine.

[37]  P. Farries,et al.  Processing of Nextel™ 720/mullite composition composite using electrophoretic deposition , 2000 .

[38]  M. Barbosa,et al.  Effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates. , 1996, Biomaterials.

[39]  T. Tateishi,et al.  Fretting corrosion resistance and fretting corrosion product cytocompatibility of ferritic stainless steel. , 1997, Journal of biomedical materials research.

[40]  G Dearnaley,et al.  Diamond-like carbon: a potential means of reducing wear in total joint replacements. , 1993, Clinical materials.

[41]  H. Taoda,et al.  Preparation of TiO_2-coated Hydroxyapatite Single Crystals , 2000 .

[42]  A. Acharya,et al.  Corrosion and Degradation of Implant Materials , 1979 .

[43]  A. Matthews,et al.  Deposition of layered bioceramic hydroxyapatite/TiO2 coatings on titanium alloys using a hybrid technique of micro-arc oxidation and electrophoresis , 2000 .

[44]  R. Tarr,et al.  Histopathology and metallurgical analysis of a removed Lane plate at 53 years postimplantation: a case report. , 1983, Journal of biomedical materials research.

[45]  R. Zeisler,et al.  Investigations of the corrosive deposition of components of metal implants and of the behaviour of biological trace elements in metallosis tissue by means of instrumental multi-element activation analysis , 1974 .

[46]  J. Cohen,et al.  Fretting Corrosion in Orthopedic Implants , 1968, Clinical orthopaedics and related research.

[47]  Roy G. Williams Observations on the repair of injuries to bone growing from autografts in rabbits , 1960, The Anatomical record.

[48]  F. W. Sunderman,et al.  Carcinogenicity of metal alloys in orthopedic prostheses: clinical and experimental studies. , 1989, Fundamental and applied toxicology : official journal of the Society of Toxicology.

[49]  M. Barbosa,et al.  Corrosion resistance of titanium CP in saline physiological solutions with calcium phosphate and proteins , 1993 .

[50]  P. Lessing,et al.  Electrophoretic deposition [EPD] applied to reaction joining of silicon carbide and silicon nitride ceramics , 2000 .

[51]  A. Townshend Metals and their Compounds in the Environment. Occurrence, Analysis and Biological Relevance , 1993 .

[52]  P. Ducheyne,et al.  Compositional variations in the surface and interface of calcium phosphate ceramic coatings on Ti and Ti-6Al-4V due to sintering and immersion. , 1991, Biomaterials.

[53]  J. Lemons Handbook of bioactive ceramics. vol. 1, bioactive glasses and glass‐ceramics and vol. 2, calcium phosphate and hydroxylapatite ceramics. T. Yamamuro L. Hench J. Wilson CRC Press, Boca Raton, FL, 1990. , 1991 .

[54]  Bundy Kj,et al.  Corrosion and other electrochemical aspects of biomaterials. , 1994 .

[55]  G. Steiner,et al.  Hydroxyapatite nucleation on Na ion implanted Ti surfaces , 2000 .

[56]  D. Bozentka Biological performance of materials: fundamentals of biocompatibility , 1993 .

[57]  S. Ban,et al.  Electrochemical corrosion behaviour of hydroxyapatite-glass-titanium composite. , 1991, Biomaterials.

[58]  R. Pilliar Modern metal processing for improved load-bearing surgical implants. , 1991, Biomaterials.