Sagittal profile of the femoral condyles and its application to femorotibial contact analysis.

Measurements of the sagittal profiles of the articular surfaces of 24 femoral condyles were performed using a laser range finder. An algebraic algorithm was developed to reconstruct the measured sagittal profiles with simple geometry. In particular, it has been shown that a two-circular-arc model provides a very accurate reconstruction of the actual profiles in the femorotibial contact region. The average sagittal profile was used for a femorotibial contact analysis of TKA implants. The contact analysis was performed by using a rigid-body-spring model extended to the case of nonlinear force-deformation behavior of the tibial polyethylene component.

[1]  Morrison Jb Function of the knee joint in various activities. , 1969 .

[2]  Jb Morrison Bioengineering analysis of force actions transmitted by the knee joint , 1970 .

[3]  Mensch Js,et al.  Knee morphology as a guide to knee replacement. , 1975 .

[4]  Tadahiko Kawai,et al.  Some consideration on the finite element method , 1980 .

[5]  J Wismans,et al.  A three-dimensional mathematical model of the knee-joint. , 1980, Journal of biomechanics.

[6]  U. Wyss,et al.  Dimensions of the Femoral Condyles , 1982 .

[7]  U Rehder Morphometrical studies on the symmetry of the human knee joint: femoral condyles. , 1983, Journal of biomechanics.

[8]  P S Walker,et al.  Geometry and motion of the knee for implant and orthotic design. , 1985, Journal of biomechanics.

[9]  R Huiskes,et al.  Analytical stereophotogrammetric determination of three-dimensional knee-joint geometry. , 1985, Journal of biomechanics.

[10]  D L Bartel,et al.  The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. , 1985, Journal of biomechanical engineering.

[11]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[12]  Y. Yoshioka,et al.  The anatomy and functional axes of the femur. , 1987, The Journal of bone and joint surgery. American volume.

[13]  P S Walker,et al.  The effects of knee brace hinge design and placement on joint mechanics. , 1988, Journal of biomechanics.

[14]  P S Walker,et al.  Bearing surface design in total knee replacement. , 1988, Engineering in medicine.

[15]  L Carlsson,et al.  Morphometrical studies of human femoral condyles. , 1989, Journal of biomedical engineering.

[16]  M. Freeman,et al.  A correlative study of the geometry and anatomy of the distal femur. , 1990, Clinical orthopaedics and related research.

[17]  E Y Chao,et al.  Normal axial alignment of the lower extremity and load-bearing distribution at the knee. , 1990, Clinical orthopaedics and related research.

[18]  P. Walker,et al.  Prediction of total knee motion using a three-dimensional computer-graphics model. , 1990, Journal of biomechanics.

[19]  P S Walker,et al.  Range of motion in total knee arthroplasty. A computer analysis. , 1991, Clinical orthopaedics and related research.

[20]  V C Mow,et al.  Quantitation of articular surface topography and cartilage thickness in knee joints using stereophotogrammetry. , 1991, Journal of biomechanics.

[21]  H. Grootenboer,et al.  Articular contact in a three-dimensional model of the knee. , 1991, Journal of Biomechanics.

[22]  M. Zoghi,et al.  A Three-Dimensional Morphometrical Study of the Distal Human Femur , 1992, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  Ashutosh Kumar Singh,et al.  The Axes of Rotation of the Knee , 1993, Clinical orthopaedics and related research.

[24]  G. Ateshian A B-spline least-squares surface-fitting method for articular surfaces of diarthrodial joints. , 1993, Journal of biomechanical engineering.

[25]  R. Herzog,et al.  Measurements of the Intercondylar Notch by Plain Film Radiography and Magnetic Resonance Imaging , 1994, The American journal of sports medicine.

[26]  S. Waldman,et al.  Compressive stress relaxation behavior of irradiated ultra-high molecular weight polyethylene at 37°C , 1994 .

[27]  D. Bartel,et al.  Stresses in polyethylene components of contemporary total knee replacements. , 1995, Clinical orthopaedics and related research.

[28]  K Yasuda,et al.  Contact analysis of ultrahigh molecular weight polyethylene articular plate in artificial knee joint during gait movement. , 1996, Journal of biomechanical engineering.

[29]  T. Andriacchi,et al.  Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. , 1997, Journal of biomechanics.

[30]  E. Chao,et al.  A comparison of different methods in predicting static pressure distribution in articulating joints. , 1997, Journal of biomechanics.

[31]  M. Harris,et al.  An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film. , 1999, Journal of biomechanics.

[32]  Joseph D. Bronzino,et al.  Biomechanics: Principles and Applications , 2002 .