Experimental analysis of drilling process in cortical bone.

Bone drilling is an essential part in orthopaedics, traumatology and bone biopsy. Prediction and control of drilling forces and torque are critical to the success of operations involving bone drilling. This paper studied the drilling force, torque and drilling process with automatic and manual drill penetrating into bovine cortical bone. The tests were performed on a drilling system which is used to drill and measure forces and torque during drilling. The effects of drilling speed, feed rate and drill bit diameter on force and torque were discussed separately. The experimental results were proven to be in accordance with the mathematic expressions introduced in this paper. The automatic drilling saved drilling time by 30-60% in the tested range and created less vibration, compared to manual drilling. The deviation between maximum and average force of the automatic drilling was 5N but 25N for manual drilling. To conclude, using the automatic method has significant advantages in control drilling force, torque and drilling process in bone drilling.

[1]  D Vashishth,et al.  Contribution, development and morphology of microcracking in cortical bone during crack propagation. , 2000, Journal of biomechanics.

[2]  M. T. Hillerya,et al.  Temperature effects in the drilling of human and bovine bone , 1999 .

[3]  D Vashishth,et al.  Crack growth resistance in cortical bone: concept of microcrack toughening. , 1997, Journal of biomechanics.

[4]  Ming-Dar Tsai,et al.  Automatic spinal disease diagnoses assisted by 3D unaligned transverse CT slices. , 2004, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[5]  Richard E. DeVor,et al.  A Mechanistic Model to Predict the Cutting Force System for Arbitrary Drill Point Geometry , 1998 .

[6]  Yoed Rabin,et al.  A new thermal model for bone drilling with applications to orthopaedic surgery. , 2011, Medical engineering & physics.

[7]  Zhe Qin,et al.  Drilling Force and Temperature of Bone by Surgical Drill , 2010 .

[8]  K Alam,et al.  Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone. , 2011, Medical engineering & physics.

[9]  S. Karmani,et al.  The design and function of surgical drills and K-wires , 2004 .

[10]  Xiao Hu Zheng,et al.  Optimization of Twist Drill’s Geometry for Cast Iron , 2010 .

[11]  Kouhei Ohnishi,et al.  Telerobotic-assisted bone-drilling system using bilateral control with feed operation scaling and cutting force scaling , 2012, The international journal of medical robotics + computer assisted surgery : MRCAS.

[12]  G. Augustin,et al.  Cortical bone drilling and thermal osteonecrosis. , 2012, Clinical biomechanics.

[13]  Vadim V. Silberschmidt,et al.  Finite element analysis of forces of plane cutting of cortical bone , 2009 .

[14]  Deepak Vashishth,et al.  Rising crack-growth-resistance behavior in cortical bone: implications for toughness measurements. , 2004, Journal of biomechanics.

[15]  J A Albright,et al.  Surgical drilling: design and performance of an improved drill. , 1982, Journal of biomechanical engineering.

[16]  Benedetto Allotta,et al.  Study on a mechatronic tool for drilling in the osteosynthesis of long bones: Tool/bone interaction, modeling and experiments , 1996 .

[17]  Ming Dar Tsai,et al.  Virtual reality simulator for osteotomy and fusion involving the musculoskeletal system. , 2002, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[18]  Toma Udiljak,et al.  Thermal osteonecrosis and bone drilling parameters revisited , 2007, Archives of Orthopaedic and Trauma Surgery.

[19]  J. Dowell,et al.  Orthopaedic bone drills-can they be improved? Temperature changes near the drilling face. , 1996, The Journal of bone and joint surgery. British volume.

[20]  Danko Brezak,et al.  Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill , 2012, International Orthopaedics.

[21]  C. Rubenstein,et al.  The torque and thrust force in twist drilling—II. Comparison of experimental observations with deductions from theory , 1991 .

[22]  Wen-Yo Lee,et al.  Control and breakthrough detection of a three-axis robotic bone drilling system , 2006 .

[23]  Richard E. DeVor,et al.  Modeling and prediction of hole profile in drilling, Part 1: modeling drill dynamics in the presence of drill alignment errors , 2003 .

[24]  J. R. Hewit,et al.  Robot-assisted invasive orthopaedic surgery , 1996 .

[25]  C. Rubenstein The torque and thrust force in twist drilling—I. Theory , 1991 .

[26]  B. Arda Gozen,et al.  Modeling and experimentation of bone drilling forces. , 2012, Journal of biomechanics.

[27]  Václav Klika,et al.  Remodelling of living bone induced by dynamic loading and drug delivery - Numerical modelling and clinical treatment , 2010, Math. Comput. Simul..

[28]  C. Rubenstein,et al.  The torque and thrust arising from contact at the chisel edge and margins in spade drilling of ductile materials , 1989 .

[29]  Shih-Tseng Lee,et al.  Force control and breakthrough detection of a bone-drilling system , 2004 .

[30]  Ming-Dar Tsai,et al.  Three-dimensional hip morphology analysis using CT transverse sections to automate diagnoses and surgery managements , 2005, Comput. Biol. Medicine.

[31]  Ming Dar Tsai,et al.  A new method for lumbar herniated inter-vertebral disc diagnosis based on image analysis of transverse sections. , 2002, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.