Technology Insight: the evolution of tissue-engineered vascular grafts—from research to clinical practice

There is a considerable clinical need for alternatives to the autologous vein and artery tissues used for vascular reconstructive surgeries such as CABG, lower limb bypass, arteriovenous shunts and repair of congenital defects to the pulmonary outflow tract. So far, synthetic materials have not matched the efficacy of native tissues, particularly in small diameter applications. The development of cardiovascular tissue engineering introduced the possibility of a living, biological graft that might mimic the functional properties of native vessels. While academic research in the field of tissue engineering in general has been active, as yet there has been no clear example of clinical and commercial success. The recent transition of cell-based therapies from experimental to clinical use has, however, reinvigorated the field of cardiovascular tissue engineering. Here, we discuss the most promising approaches specific to tissue-engineered blood vessels and briefly introduce our recent clinical results. The unique regulatory, reimbursement and production challenges facing personalized medicine are also discussed.

[1]  M A Moses,et al.  Tissue engineering of autologous aorta using a new biodegradable polymer. , 1999, The Annals of thoracic surgery.

[2]  T. Matsuda,et al.  Venous Reconstruction Using Hybrid Vascular Tissue Composed of Vascular Cells and Collagen: Tissue Regeneration Process , 1996 .

[3]  N. L'Heureux,et al.  Human tissue-engineered blood vessels for adult arterial revascularization , 2007, Nature Medicine.

[4]  S. Williams,et al.  Cellular proliferation and macrophage populations associated with implanted expanded polytetrafluoroethylene and polyethyleneterephthalate. , 2000, Journal of biomedical materials research.

[5]  Christopher Breuer,et al.  Artificial blood vessel: the Holy Grail of peripheral vascular surgery. , 2005, Journal of vascular surgery.

[6]  Chrysanthi Williams,et al.  Small-diameter artificial arteries engineered in vitro. , 2005, Circulation research.

[7]  C. H. Sparks Silicone mandril method for growing reinforced autogenous femoro-popliteal artery grafts in situ. , 1973, Annals of surgery.

[8]  The Time Investigators Trial of invasive versus medical therapy in elderly patients with chronic symptomatic coronary-artery disease (TIME): a randomised trial , 2001, The Lancet.

[9]  E Bell,et al.  A blood vessel model constructed from collagen and cultured vascular cells. , 1986, Science.

[10]  Y. Imai,et al.  Transplantation of a tissue-engineered pulmonary artery. , 2001, The New England journal of medicine.

[11]  S. Milz,et al.  Continuous graft perfusion: optimizing the quality of saphenous vein grafts. , 2002, The heart surgery forum.

[12]  M S Conte,et al.  The ideal small arterial substitute: a search for the Holy Grail? , 1998, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[13]  R. Tranquillo,et al.  Mechanisms of stiffening and strengthening in media-equivalents fabricated using glycation. , 2000, Journal of biomechanical engineering.

[14]  A. Seifalian,et al.  The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. , 2006, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[15]  V. Bernhard,et al.  Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. , 1986, Journal of vascular surgery.

[16]  J. Campbell,et al.  Novel vascular graft grown within recipient's own peritoneal cavity. , 1999, Circulation research.

[17]  Debby Gawlitta,et al.  Properties of engineered vascular constructs made from collagen, fibrin, and collagen-fibrin mixtures. , 2004, Biomaterials.

[18]  J. Lavee,et al.  Complications of saphenous vein harvesting following coronary artery bypass surgery. , 1989, The Journal of cardiovascular surgery.

[19]  Narutoshi Hibino,et al.  Midterm clinical result of tissue-engineered vascular autografts seeded with autologous bone marrow cells. , 2005, The Journal of thoracic and cardiovascular surgery.

[20]  James A. Russell,et al.  Engineering of fibrin-based functional and implantable small-diameter blood vessels. , 2005 .

[21]  R. Sapsford,et al.  Early and late patency of expanded polytetrafluoroethylene vascular grafts in aorta-coronary bypass. , 1981, The Journal of thoracic and cardiovascular surgery.

[22]  R. Green,et al.  Financial impact of endoscopic vein harvest for infrainguinal bypass. , 2003, Journal of vascular surgery.

[23]  Julie H. Campbell,et al.  Dog peritoneal and pleural cavities as bioreactors to grow autologous vascular grafts. , 2004, Journal of vascular surgery.

[24]  P. Zilla,et al.  Clinical autologous in vitro endothelialization of 153 infrainguinal ePTFE grafts. , 2001, The Annals of thoracic surgery.

[25]  E. Wijelath,et al.  Vascular graft healing. III. FTIR analysis of ePTFE graft samples from implanted bigrafts. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[26]  J. Seeger Management of Patients with Prosthetic Vascular Graft Infection , 2000, The American surgeon.

[27]  B. Griffith,et al.  Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery. , 2005, The Annals of thoracic surgery.

[28]  Eugene H Blackstone,et al.  Comparison of saphenous vein and internal thoracic artery graft patency by coronary system. , 2005, The Annals of thoracic surgery.

[29]  Seeger Jm Management of patients with prosthetic vascular graft infection. , 2000 .

[30]  R T Tranquillo,et al.  A fibrin-based arterial media equivalent. , 2003, Journal of biomedical materials research. Part A.

[31]  C H Sparks,et al.  Autogenous grafts made to order. , 1969, The Annals of thoracic surgery.

[32]  W. Moore,et al.  Failure of PTFE infrainguinal revascularization: Patterns, management alternatives, and outcome , 1991, Annals of vascular surgery.

[33]  F. Pileggi,et al.  The Medicine, Angioplasty or Surgery Study (MASS): a prospective, randomized trial of medical therapy, balloon angioplasty or bypass surgery for single proximal left anterior descending artery stenoses. , 1995, Journal of the American College of Cardiology.

[34]  Robert M. Nerem,et al.  Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro , 2000, Annals of Biomedical Engineering.

[35]  B. Lown,et al.  Unanswered ethical and scientific questions for trials of invasive interventions for coronary disease: The case of single vessel disease , 2004, Current controlled trials in cardiovascular medicine.

[36]  R Langer,et al.  Functional arteries grown in vitro. , 1999, Science.

[37]  G. Delaria,et al.  Leg wound complications associated with coronary revascularization. , 1981, The Journal of thoracic and cardiovascular surgery.

[38]  J. H. van Bockel,et al.  Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature. , 2004, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[39]  Aaron Bouchie,et al.  Tissue engineering firms go under , 2002, Nature Biotechnology.

[40]  R. Torensma Blood vessels engineered from human cells , 2005, The Lancet.

[41]  R. Sodian,et al.  Tissue engineering of small caliber vascular grafts. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.