Evaluation of Deformable Image Registration Methods for Dose Monitoring in Head and Neck Radiotherapy

In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44 mm (1.30 mm) and 2.54 mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85 Gy (0.93 Gy) and 0.88 Gy (0.95 Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03 Gy (SD = 2.27 Gy, range: 1.06–8.91 Gy).

[1]  Timothy E. Schultheiss,et al.  It is not appropriate to “deform” dose along with deformable image registration in adaptive radiotherapy: Point/Counterpoint , 2012 .

[2]  Randall K Ten Haken,et al.  Parotid gland function after radiotherapy: the combined michigan and utrecht experience. , 2008, International journal of radiation oncology, biology, physics.

[3]  R Mohan,et al.  Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers. , 2000, International journal of radiation oncology, biology, physics.

[4]  Weiguo Lu,et al.  Assessment of parotid gland dose changes during head and neck cancer radiotherapy using daily megavoltage computed tomography and deformable image registration. , 2008, International journal of radiation oncology, biology, physics.

[5]  T. Vercauteren,et al.  Three-phase adaptive dose-painting-by-numbers for head-and-neck cancer: initial results of the phase I clinical trial. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  Y. Pointreau,et al.  Dose de tolérance à l’irradiation des tissus sains : la vessie , 2010 .

[7]  T. Schuster,et al.  Adaptive radiotherapy for soft tissue changes during helical tomotherapy for head and neck cancer , 2012, Strahlentherapie und Onkologie.

[8]  J Pouliot,et al.  Dose-guided radiation therapy with megavoltage cone-beam CT. , 2006, The British journal of radiology.

[9]  Radhe Mohan,et al.  Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. , 2004, International journal of radiation oncology, biology, physics.

[10]  Pascal Haigron,et al.  Surface-Constrained Nonrigid Registration for Dose Monitoring in Prostate Cancer Radiotherapy , 2014, IEEE Transactions on Medical Imaging.

[11]  S. Leung,et al.  Prospective randomized study of intensity-modulated radiotherapy on salivary gland function in early-stage nasopharyngeal carcinoma patients. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[12]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[13]  Katja M Langen,et al.  A virtual phantom library for the quantification of deformable image registration uncertainties in patients with cancers of the head and neck. , 2013, Medical physics.

[14]  Emma Hall,et al.  Parotid-sparing intensity modulated versus conventional radiotherapy in head and neck cancer (PARSPORT): a phase 3 multicentre randomised controlled trial , 2011, The Lancet. Oncology.

[15]  Yasumasa Nishimura,et al.  Importance of the initial volume of parotid glands in xerostomia for patients with head and neck cancers treated with IMRT. , 2005, Japanese journal of clinical oncology.

[16]  Josien P. W. Pluim,et al.  Preconditioned Stochastic Gradient Descent Optimisation for Monomodal Image Registration , 2011, MICCAI.

[17]  T Kron,et al.  Comment on "it is not appropriate to 'deform' dose along with deformable image registration in adaptive radiotherapy" [Med. Phys. 39, 6531-6533 (2012)]. , 2013, Medical physics.

[18]  Ping Xia,et al.  Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma. , 2002, International journal of radiation oncology, biology, physics.

[19]  Max A. Viergever,et al.  elastix: A Toolbox for Intensity-Based Medical Image Registration , 2010, IEEE Transactions on Medical Imaging.

[20]  Matthias Guckenberger,et al.  A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapy , 2012, Radiation oncology.

[21]  F. Mornex,et al.  [Normal tissue tolerance to external beam radiation therapy: lung]. , 2010, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[22]  Ping Xia,et al.  Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer. , 2006, International journal of radiation oncology, biology, physics.

[23]  Colin G Orton,et al.  Point/counterpoint: it is not appropriate to "deform" dose along with deformable image registration in adaptive radiotherapy. , 2012, Medical physics.

[24]  J. Gérard,et al.  [Good knowledge and respect for dosage tolerance of organs at risk and healthy tissues is one of the major aspects of the profession of radiotherapeutic oncology]. , 2010, Cancer Radiothérapie.

[25]  Sebastian Schafer,et al.  Extra-dimensional Demons: a method for incorporating missing tissue in deformable image registration. , 2012, Medical physics.

[26]  T Kron,et al.  Is it sensible to "deform" dose? 3D experimental validation of dose-warping. , 2012, Medical physics.

[27]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[28]  Hualiang Zhong,et al.  An energy transfer method for 4D Monte Carlo dose calculation. , 2008, Medical physics.

[29]  C. Koning,et al.  Dose-guided radiotherapy: potential benefit of online dose recalculation for stereotactic lung irradiation in patients with non-small-cell lung cancer. , 2012, International journal of radiation oncology, biology, physics.

[30]  Qiuwen Wu,et al.  Adaptive replanning strategies accounting for shrinkage in head and neck IMRT. , 2009, International journal of radiation oncology, biology, physics.

[31]  Shih-Neng Yang,et al.  Impact of body-mass factors on setup displacement in patients with head and neck cancer treated with radiotherapy using daily on-line image guidance , 2014, Radiation oncology.

[32]  Ik Jae Lee,et al.  Is There a Clinical Benefit to Adaptive Planning During Tomotherapy in Patients with Head and Neck Cancer at Risk for Xerostomia? , 2012, American journal of clinical oncology.

[33]  J. Sham,et al.  Xerostomia and quality of life after intensity-modulated radiotherapy vs. conventional radiotherapy for early-stage nasopharyngeal carcinoma: initial report on a randomized controlled clinical trial. , 2006, International journal of radiation oncology, biology, physics.

[34]  T E Schultheiss,et al.  Response to "comment on 'It is not appropriate to "deform" dose along with deformable image registration in adaptive radiotherapy'" [Med. Phys. 39, 6531-6533 (2012)]. , 2013, Medical physics.

[35]  Jean-Philippe Thirion,et al.  Image matching as a diffusion process: an analogy with Maxwell's demons , 1998, Medical Image Anal..

[36]  Luis Ibáñez,et al.  The ITK Software Guide , 2005 .

[37]  Jean-François Daisne,et al.  Atlas-based automatic segmentation of head and neck organs at risk and nodal target volumes: a clinical validation , 2013, Radiation oncology.

[38]  Jan-Jakob Sonke,et al.  Deformable image registration for adaptive radiation therapy of head and neck cancer: accuracy and precision in the presence of tumor changes. , 2014, International journal of radiation oncology, biology, physics.

[39]  Benoît Macq,et al.  Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[40]  Gregory C Sharp,et al.  Scale invariant feature transform in adaptive radiation therapy: a tool for deformable image registration assessment and re-planning indication , 2013, Physics in medicine and biology.

[41]  Lei Dong,et al.  Adaptive radiotherapy for head and neck cancer--dosimetric results from a prospective clinical trial. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[42]  Yasumasa Nishimura,et al.  Volume and dosimetric changes and initial clinical experience of a two-step adaptive intensity modulated radiation therapy (IMRT) scheme for head and neck cancer. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.