Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material

Skin dose assessment for chest wall radiotherapy is important to ensure sufficient dose to the surface target volume without excessive skin reaction. This study quantified changes to the surface doses as a function of bolus material for conventional and intensity modulated radiation therapy (IMRT) tangential fields. Three types of bolus materials (2 mm solid, 2 mm fine mesh and 3.2 mm large mesh Aquaplast) were compared with Superflab. Surface dose measurements were performed using an Attix parallel plate chamber in a flat solid water phantom at 0 degrees , 45 degrees and 70 degrees incident angles. Over-response correction factors were applied to the Attix chamber results for different incident angles. Surface dose measurements on an anthropomorphic phantom were done using a thermoluminescent dosimeter extrapolation method. Dose characteristics of Superflab and solid Aquaplast were within 2% of solid water material. No significant differences (within 3%) in the surface dose were found between conventional and IMRT tangential techniques. The bolus effect was large for chest wall tangential radiotherapy, with up to an 82% increase using 2 mm fine mesh Aquaplast. The dosimetric effect of different Aquaplast materials has been quantified in this work. These materials can be used to create a custom bolus with potentially better reproducibility of placement.

[1]  C. Ma,et al.  Ultra-thin TLDs for skin dose determination in high energy photon beams , 2006, Physics in medicine and biology.

[2]  F. Khan,et al.  Plane-parallel ionization chamber response in the buildup region of obliquely incident photon beams. , 1997, Medical physics.

[3]  G J Kutcher,et al.  Intensity-modulated tangential beam irradiation of the intact breast. , 1999, International journal of radiation oncology, biology, physics.

[4]  P. Metcalfe,et al.  Measurement of radiotherapy x-ray skin dose on a chest wall phantom. , 2000, Medical physics.

[5]  R Mohan,et al.  Investigation of buildup dose from electron contamination of clinical photon beams. , 1983, Medical physics.

[6]  Antonio Teijeiro,et al.  Characterization of electron contamination in megavoltage photon beams. , 2005, Medical physics.

[7]  T C Zhu,et al.  Electron contamination in 8 and 18 MV photon beams. , 1998, Medical physics.

[8]  D E Mellenberg,et al.  Dose behind various immobilization and beam-modifying devices. , 1995, International journal of radiation oncology, biology, physics.

[9]  G. Starkschall,et al.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. , 1998, Medical physics.

[10]  A Lamb,et al.  Investigation and modelling of the surface dose from linear accelerator produced 6 and 10 MV photon beams. , 1998, Physics in medicine and biology.

[11]  Evaluation of surface and superficial dose for head and neck treatments using conventional or intensity-modulated techniques. , 2006, Physics in medicine and biology.

[12]  M. Butson,et al.  TLD extrapolation for skin dose determination in vivo. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  F. Khan,et al.  Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers. , 1990, Medical physics.

[14]  Simon J Thomas,et al.  The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT). , 2004, Physics in medicine and biology.

[15]  J Yang,et al.  Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation. , 2004, Physics in medicine and biology.

[16]  P. Roberson,et al.  Surface buildup dose dependence on photon field delivery technique for IMRT , 2004, Journal of applied clinical medical physics.

[17]  Surface dose measurement using TLD powder extrapolation. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[18]  T. Chu,et al.  Skin dose measurement by using ultra-thin TLDs. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[19]  R. Cormack,et al.  Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations. , 2007, Medical physics.

[20]  J. A. Rawlinson,et al.  Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams. , 1992, Medical physics.

[21]  B. Gerbi The response characteristics of a newly designed plane-parallel ionization chamber in high-energy photon and electron beams. , 1993, Medical physics.

[22]  G Luxton,et al.  TLD dose measurement: a simplified accurate technique for the dose range from 0.5 cGy to 1000 cGy. , 1999, Medical physics.

[23]  G. Glasgow,et al.  Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays. , 2003, Medical physics.

[24]  F. Khan The physics of radiation therapy , 1985 .

[25]  F. Khan,et al.  Dose buildup for obliquely incident photon beams. , 1987, Medical physics.

[26]  P J Biggs,et al.  Electrons as the cause of the observed dmax shift with field size in high energy photon beams. , 1979, Medical physics.

[27]  P. Higgins,et al.  Evaluation of surface and superficial dose for head and neck treatments using conventional or intensity-modulated techniques , 2006, Physics in medicine and biology.

[28]  D. McShan,et al.  Use of an octree-like geometry for 3-D dose calculations. , 1993, Medical physics.

[29]  Ping Xia,et al.  Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma. , 2002, International journal of radiation oncology, biology, physics.

[30]  R Mohan,et al.  Sources of electron contamination for the Clinac-35 25-MV photon beam. , 1983, Medical physics.

[31]  T. Bortfeld,et al.  The Use of Computers in Radiation Therapy , 2000, Springer Berlin Heidelberg.

[32]  P. Metcalfe,et al.  X-ray surface dose measurements using TLD extrapolation. , 1993, Medical physics.

[33]  Scott W. Hadley,et al.  Effects of immobilization mask material on surface dose , 2005, Journal of applied clinical medical physics.