A new hybrid PLL for interconnecting Renewable Energy Systems to the grid

There is a need to develop new control strategies for interconnecting Renewable Energy Sources (RES) to the power system due to the ever increasing penetration of RES and in particular for wind power systems (WPS). The control strategies are typically based on a fast and accurate detection of the phase angle of the grid voltage which may be estimated by using a Phase-Locked Loop (PLL) control circuit. The performance of the PLL under normal and abnormal operational conditions is a crucial aspect, since the RES is desired to operate to support the power system under grid fault conditions. This paper investigates the performance of three different PLLs: a synchronous reference frame PLL (dqPLL), a stationary reference frame PLL (αβPLL), and a decoupled double synchronous reference frame PLL (ddsrfPLL). The results of this investigation motivate to the development of a new hybrid PLL which is a combination of the abovementioned PLLs and uses the advantages of each PLL. The proposed decoupled stationary reference frame PLL (dαβPLL) may be an appropriate solution to use in an interconnected RES with Ride Through Fault (RTF) capability, since it prevails the other PLLs with regards to its accuracy under unbalanced faults. Further, it has a lower deviation of the estimated phase after the fault occurs. The performance of the new hybrid dαβPLL is verified through simulations and experiments. Further the new PLL is used in an interconnected RES through experiments under normal and RTF operation.

[1]  Guan-Chyun Hsieh,et al.  Phase-locked loop techniques. A survey , 1996, IEEE Trans. Ind. Electron..

[2]  Tzung-Lin Lee,et al.  Discrete Frequency-Tuning Active Filter to Suppress Harmonic Resonances of Closed-Loop Distribution Power Systems , 2011, IEEE Transactions on Power Electronics.

[3]  G. Garcera,et al.  An Adaptive Control System for Three-Phase Photovoltaic Inverters Working in a Polluted and Variable Frequency Electric Grid , 2012, IEEE Transactions on Power Electronics.

[4]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[5]  O. Gomis-Bellmunt,et al.  Current Control Reference Calculation Issues for the Operation of Renewable Source Grid Interface VSCs Under Unbalanced Voltage Sags , 2011, IEEE Transactions on Power Electronics.

[6]  I. Erlich,et al.  Advanced grid requirements for the integration of wind turbines into the German transmission system , 2006, 2006 IEEE Power Engineering Society General Meeting.

[7]  M. Liserre,et al.  Reactive Power Control for Improving Wind Turbine System Behavior Under Grid Faults , 2009, IEEE Transactions on Power Electronics.

[8]  R. Teodorescu,et al.  A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions , 2012, IEEE Transactions on Power Electronics.

[9]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[10]  Fei Wang,et al.  Pliant Active and Reactive Power Control for Grid-Interactive Converters Under Unbalanced Voltage Dips , 2011, IEEE Transactions on Power Electronics.

[11]  S.-K. Chung,et al.  Phase-locked loop for grid-connected three-phase power conversion systems , 2000 .

[12]  S. Maestri,et al.  Variable Sampling Period Filter PLL for Distorted Three-Phase Systems , 2012, IEEE Transactions on Power Electronics.

[13]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[14]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[15]  Hong-Hee Lee,et al.  Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear Loads , 2011, IEEE Transactions on Power Electronics.

[16]  Irene Yu-Hua Gu,et al.  Signal processing of power quality disturbances , 2006 .

[17]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[18]  F. Blaabjerg,et al.  Flexible control of small wind turbines with grid failure detection operating in stand-alone and grid-connected mode , 2004, IEEE Transactions on Power Electronics.

[19]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[20]  Gene F. Franklin,et al.  Feedback Control of Dynamic Systems , 1986 .

[21]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .