Constrained Kinematic Control in Minimally Invasive Robotic Surgery Subject to Remote Center of Motion Constraint

This paper presents kinematic control of surgical robotic systems subject to Remote Center of Motion (RCM) constraint in Minimally Invasive Robotic Surgeries (MIRS). A novel kinematic formulation for surgical systems is derived and the movement restriction in incision point, known as RCM constraint, is resolved by active control of the system through a so-called RCM-constrained Jacobian. The proposed minimal Jacobian matrix can realize fixed/moving trocar constraint effectively in comparison with the state-of-the-arts. In the following, an analysis related to the dexterity of the constrained system is introduced and an index for manipulability of the constrained system is introduced. The proposed approach is validated through several numerical simulations as well as experiments in a 7DoFs and 9DoFs MIRS scenarios. The results show the efficiency and the precision of the proposed method.

[1]  Russell H. Taylor,et al.  Computer-Integrated Surgery: Technology and Clinical Applications , 1995 .

[2]  J. M. Sackier,et al.  Robotically assisted laparoscopic surgery , 2008, Surgical Endoscopy.

[3]  Russell H. Taylor,et al.  Performance of Surgical Robots with Automatically Generated Spatial Virtual Fixtures , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[4]  Bijan Shirinzadeh,et al.  Motion control analysis of a parallel robot assisted minimally invasive surgery/microsurgery system (PRAMiSS) , 2013 .

[5]  J. Edward Colgate,et al.  Toward robot-assisted vascular microsurgery in the retina , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[6]  Alois Knoll,et al.  Inverse Kinematics and Modelling of a System for Robotic Surgery , 2004 .

[7]  Gabor Fichtinger,et al.  Virtual Remote Center of Motion control for needle placement robots , 2004 .

[8]  Tobias Ortmaier,et al.  Manipulability and Accuracy Measures for a Medical Robot in Minimally Invasive Surgery , 2004 .

[9]  Rainer Konietschke,et al.  A workspace analysis method to support intraoperative trocar placement in minimally invasive robotic surgery (MIRS) , 2012, CURAC.

[10]  Russell H. Taylor,et al.  Constrained Cartesian motion control for teleoperated surgical robots , 1996, IEEE Trans. Robotics Autom..

[11]  Bruno Siciliano,et al.  Dynamic multi-priority control in redundant robotic systems1 , 2013, Robotica.

[12]  Bijan Shirinzadeh,et al.  Remote centre-of-motion control algorithms of 6-RRCRR parallel robot assisted surgery system (PRAMiSS) , 2012, 2012 IEEE International Conference on Robotics and Automation.

[13]  Jian S. Dai,et al.  Robotics for Minimally Invasive Surgery: A Historical Review from the Perspective of Kinematics , 2009 .

[14]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[15]  Michael D. Naish,et al.  On constrained manipulation in robotics-assisted minimally invasive surgery , 2010, 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[16]  Tsuneo Yoshikawa,et al.  Manipulability and redundancy control of robotic mechanisms , 1985, Proceedings. 1985 IEEE International Conference on Robotics and Automation.

[17]  Yulun Wang,et al.  Robotic surgery - the transatlantic case , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[18]  Nobuhiko Hata,et al.  Needle Guiding Robot for MR-guided Microwave Thermotherapy of Liver Tumor using Motorized Remote-Center-of-Motion Constraint , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[19]  Giulio Sandini,et al.  Manipulability analysis , 2012, 2012 12th IEEE-RAS International Conference on Humanoid Robots (Humanoids 2012).

[20]  Rajnikant V. Patel,et al.  Optimal Remote Center-of-Motion Location for Robotics-Assisted Minimally-Invasive Surgery , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[21]  Pål Johan From On the Kinematics of Robotic-assisted Minimally Invasive Surgery , 2013 .

[22]  Alireza Mirbagheri,et al.  A novel remote center of motion mechanism for the force‐reflective master robot of haptic tele‐surgery systems , 2014, The international journal of medical robotics + computer assisted surgery : MRCAS.

[23]  Alin Albu-Schäffer,et al.  The DLR MIRO: a versatile lightweight robot for surgical applications , 2008, Ind. Robot.

[24]  G. Oriolo,et al.  Task control with remote center of motion constraint for minimally invasive robotic surgery , 2013, 2013 IEEE International Conference on Robotics and Automation.

[25]  Pål Johan From,et al.  Analysis of a moving remote center of motion for robotics-assisted minimally invasive surgery , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[26]  Murilo M. Marinho,et al.  A programmable remote center-of-motion controller for minimally invasive surgery using the dual quaternion framework , 2014, 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics.