2006 FRANK STINCHFIELD AWARD: Grafting of Biocompatible Polymer for Longevity of Artificial Hip Joints

Aseptic loosening induced by wear particles from the polyethylene liner is likely the most common cause of long-term total hip arthroplasty failure. We developed a novel hip polyethylene liner with the surface graft of a biocompatible phospholipid polymer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and previously reported the grafting decreased the short-term production of wear particles and the subsequent bone resorptive responses. For clinical application, we investigated the stability of the 2-methacryloyloxyethyl phosphorylcholine grafting during sterilization and the wear resistance of the sterilized liner during longer loading comparable to clinical usage. Radiographic spectroscopy confirmed the stability of the 2-methacryloyloxyethyl phosphorylcholine polymer on the liner surface after the gamma irradiation. We used a hip wear simulator up to 1 × 107 cycles to test sterilized cross-linked polyethylene liners with and without 2-methacryloyloxyethyl phosphorylcholine grafting. The 2-methacryloyloxyethyl phosphorylcholine grafting markedly decreased the friction, the production of wear particles, and the wear of the liner surface. These data suggest a marked improvement in the wear resistance of the polyethylene liner by the 2-methacryloyloxyethyl phosphorylcholine grafting for clinically relevant periods after sterilization, indicating 2-methacryloyloxyethyl phosphorylcholine grafting is a promising technology for extending longevity of artificial hips.

[1]  H Brenner,et al.  International variation in hip replacement rates , 2003, Annals of the rheumatic diseases.

[2]  Mitsuo Umezu,et al.  In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system. , 2003, Artificial organs.

[3]  A. Lewis,et al.  Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation. , 2002, Biomaterials.

[4]  M. Laberge,et al.  Sliding Friction Analysis of Phosphatidylcholine as a Boundary Lubricant for Articular Cartilage , 1993, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  J. Charnley,et al.  Total hip replacement by low-friction arthroplasty. , 1970, Clinical orthopaedics and related research.

[6]  F. Shen,et al.  Effect of Sterilization Method and Other Modifications on the Wear Resistance of Acetabular Cups Made of Ultra-High Molecular Weight Polyethylene: A Hip-Simulator Study* , 2000, The Journal of bone and joint surgery. American volume.

[7]  E. Schwarz,et al.  Efficacy of ex vivo OPG gene therapy in preventing wear debris induced osteolysis , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  J. Fisher,et al.  Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints , 2005 .

[9]  T. Wright,et al.  Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. , 1988, The Journal of bone and joint surgery. American volume.

[10]  O Johnell,et al.  Projecting the need for hip replacement over the next three decades: influence of changing demography and threshold for surgery , 1999, Annals of the rheumatic diseases.

[11]  N Nakabayashi,et al.  Why do phospholipid polymers reduce protein adsorption? , 1998, Journal of biomedical materials research.

[12]  Kazuhiko Ishihara,et al.  Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes , 1990, Polymer Journal.

[13]  Steven Kurtz,et al.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. , 2005, The Journal of bone and joint surgery. American volume.

[14]  J. Black,et al.  Metal on Metal Bearings: A Practical Alternative to Metal on Polyethylene Total Joints? , 1996, Clinical orthopaedics and related research.

[15]  H. Rubash,et al.  Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. , 2000, Journal of biomedical materials research.

[16]  A. Boskey,et al.  In Vivo RANK Signaling Blockade Using the Receptor Activator of NF‐κB:Fc Effectively Prevents and Ameliorates Wear Debris‐Induced Osteolysis via Osteoclast Depletion Without Inhibiting Osteogenesis , 2002, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[17]  K. Ishihara,et al.  Improvement of blood compatibility on cellulose hemodialysis membrane: IV. Phospholipid polymer bonded to the membrane surface. , 1999, Journal of biomaterials science. Polymer edition.

[18]  B D Butler,et al.  Surfactants identified in synovial fluid and their ability to act as boundary lubricants. , 1984, Annals of the rheumatic diseases.

[19]  T. Glant,et al.  Osteolysis: basic science. , 2001, Clinical orthopaedics and related research.

[20]  Takashi Nakamura,et al.  A Multi‐Station Hip Joint Simulator Study and Wear Characterization of Commercial Hip Endoprostheses , 2008 .

[21]  B A Hills,et al.  Boundary lubrication in vivo , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[22]  Elena Losina,et al.  Rates and Outcomes of Primary and Revision Total Hip Replacement in the United States Medicare Population , 2003, The Journal of bone and joint surgery. American volume.

[23]  R. Poss,et al.  Complications of Total Hip Arthroplasty Associated with the Use of an Acetabular Component with a Hylamer Liner* , 1997, The Journal of bone and joint surgery. American volume.

[24]  K. Ishihara,et al.  The vascular prosthesis without pseudointima prepared by antithrombogenic phospholipid polymer. , 2002, Biomaterials.

[25]  J. Fisher,et al.  The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. , 2004, Biomaterials.

[26]  T. Wright,et al.  Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[27]  G. Stachowiak,et al.  The morphology and composition of the superficial zone of mammalian articular cartilage , 1993 .

[28]  J. D. Robertson,et al.  Long-term stability of a coronary stent coating post-implantation. , 2002, Journal of biomedical materials research.

[29]  W. Harris,et al.  Surface analysis of early retrieved acetabular polyethylene liners: a comparison of conventional and highly crosslinked polyethylenes. , 2004, The Journal of arthroplasty.

[30]  J. Older Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years. , 2002, The Journal of arthroplasty.

[31]  K. Ishihara,et al.  Thermal property and processability of elastomeric polymer alloy composed of segmented polyurethane and phospholipid polymer. , 2002, Journal of biomedical materials research.

[32]  J Fisher,et al.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. , 1998, Biomaterials.

[33]  W. Flynn,et al.  Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty. , 1995, The Journal of arthroplasty.

[34]  D. Dowson,et al.  Micro-elastohydrodynamic lubrication of synovial joints. , 1986, Engineering in medicine.

[35]  T. Okano,et al.  PHOTO-INDUCED CHANGE IN WETTABILITY AND BINDING ABILITY OF AZOAROMATIC POLYMERS. , 1982 .

[36]  J. Galante,et al.  Bone resorption activity of particulate‐stimulated macrophages , 1993, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[37]  K. An,et al.  Importance of a Radial Head Component in Sorbie Unlinked Total Elbow Arthroplasty , 2002, Clinical orthopaedics and related research.

[38]  W. Maloney,et al.  Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. , 1995, The Journal of bone and joint surgery. American volume.

[39]  Ebihara,et al.  Photoinduced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on polyethylene membrane surface for obtaining blood cell adhesion resistance. , 2000, Colloids and surfaces. B, Biointerfaces.

[40]  J. P. Paul,et al.  Paper 8: Forces Transmitted by Joints in the Human Body: , 1966 .

[41]  Tomiharu Matsushita,et al.  Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis , 2004, Nature materials.

[42]  F. Shen,et al.  Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. , 1999, Clinical orthopaedics and related research.