Comparing image quality in phase contrast subμ X-ray tomography—A round-robin study

Abstract How to evaluate and compare image quality from different sub-micrometer (sub μ ) CT scans? A simple test phantom made of polymer microbeads is used for recording projection images as well as 13 CT scans in a number of commercial and non-commercial scanners. From the resulting CT images, signal and noise power spectra are modelled for estimating volume signal-to-noise ratios (3D SNR spectra). Using the same CT images, a time- and shape-independent transfer function (MTF) is computed for each scan, including phase contrast effects and image blur (MTFblur). The SNR spectra and MTF of the CT scans are compared to 2D SNR spectra of the projection images. In contrary to 2D SNR, volume SNR can be normalized with respect to the object’s power spectrum, yielding detection effectiveness (DE) a new measure which reveals how technical differences as well as operator-choices strongly influence scan quality for a given measurement time. Using DE, both source-based and detector-based sub μ CT scanners can be studied and their scan quality can be compared. Future application of this work requires a particular scan acquisition scheme which will allow for measuring 3D signal-to-noise ratios, making the model fit for 3D noise power spectra obsolete.

[1]  S. Zabler,et al.  SNR spectra as a quantitative model for image quality in polychromatic X-ray imaging , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[2]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[3]  B. Sopko,et al.  High-resolution application of YAG:Ce and LuAG:Ce imaging detectors with a CCD X-ray camera , 2008 .

[4]  J. Goodman Introduction to Fourier optics , 1969 .

[5]  S. Zabler,et al.  Using measurements of the spatial SNR to optimize phase contrast X-ray imaging , 2018 .

[6]  S. Zabler,et al.  High-resolution X-ray imaging for lab-based materials research , 2012 .

[7]  J Yorkston,et al.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology. , 1998, Medical physics.

[8]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[9]  Eric Jones,et al.  SciPy: Open Source Scientific Tools for Python , 2001 .

[10]  I. I. Rushakov,et al.  Computed Tomography , 2019, Compendium of Biomedical Instrumentation.

[11]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[12]  K. Hanson,et al.  Detectability in computed tomographic images. , 1979, Medical physics.

[13]  T. Weitkamp,et al.  ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs. , 2011, Journal of synchrotron radiation.

[16]  B. Zheng,et al.  Impact of a single distance phase retrieval algorithm on spatial resolution in X-ray inline phase sensitive imaging. , 2019, Biomedical spectroscopy and imaging.

[17]  Simon Zabler,et al.  Correcting multi material artifacts from single material phase retrieved holo-tomograms with a simple 3D Fourier method. , 2015, Optics express.

[18]  Daniele Pelliccia,et al.  Experimental characterization of the coherence properties of hard x-ray sources. , 2011, Optics express.

[19]  Andreas Koch,et al.  X-ray imaging with submicrometer resolution employing transparent luminescent screens , 1998 .

[20]  Rodney Shaw,et al.  Signal-to-noise optimization of medical imaging systems , 1999 .

[21]  Jeff Gelb,et al.  Sub-micron resolution CT for failure analysis and process development , 2008 .

[22]  V. Cosslett,et al.  X-Ray Shadow Microscope , 1951, Nature.

[23]  Christoph Heinzl,et al.  NanoXCT: development of a laboratory nano-CT system , 2014, Optics & Photonics - Optical Engineering + Applications.

[24]  G. Friedlander [Signal]. , 2020, Medecine sciences : M/S.

[25]  Michael Salamon,et al.  Industrial X-ray Computed Tomography Scanners , 2017 .