OBJECTIVES
We investigated the feasibility of using a single multi-parameter test based mainly on recombinant autoantigens for the detection of anti-nuclear autoantibodies, and analyzed the agreement between this test format and conventional techniques.
METHODS
The presence of autoantibodies was determined by a line immunoassay (LIA) in 755 sera derived from patients with different autoimmune connective tissue disorders. All sera were previously tested by standard assays that are routinely used at the 8 participating European centers.
RESULTS
The overall sensitivity and specificity of autoantibody detection by LIA was similar or higher as compared to combined conventional techniques (CCT). In particular, the detection of anti-Ro52 in systemic lupus erythematosus (SLE) sera (P = 0.004) and anti-LA in both SLE (P < 0.0009) and in Sjögren's syndrome (P < 0.0009) sera was significantly more sensitive when using LIA compared to CCT. By contrast, CCT was never more sensitive than LIA for any of the markers.
CONCLUSION
The LIA is a reliable alternative to a combination of conventional techniques for the detection of specific anti-nuclear autoantibodies. The multi-parameter test also reveals autoantibody reactivities that may not be detected when only a limited number of conventional techniques are applied.