A real-time device for converting Doppler ultrasound audio signals into fluid flow velocity.

A Doppler signal converter has been developed to facilitate cardiovascular and exercise physiology research. This device directly converts audio signals from a clinical Doppler ultrasound imaging system into a real-time analog signal that accurately represents blood flow velocity and is easily recorded by any standard data acquisition system. This real-time flow velocity signal, when simultaneously recorded with other physiological signals of interest, permits the observation of transient flow response to experimental interventions in a manner not possible when using standard Doppler imaging devices. This converted flow velocity signal also permits a more robust and less subjective analysis of data in a fraction of the time required by previous analytic methods. This signal converter provides this capability inexpensively and requires no modification of either the imaging or data acquisition system.

[1]  W. Pae,et al.  Vasoconstriction seen in coronary bypass grafts during handgrip in humans. , 2007, Journal of applied physiology.

[2]  John G. Webster,et al.  MEASUREMENT OF FLOW AND VOLUME OF BLOOD , 2008 .

[3]  L. Sinoway,et al.  Leg exercise conditioning increases peak forearm blood flow. , 1991, Journal of applied physiology.

[4]  L. Sinoway,et al.  Renal vascular responses to static handgrip: role of muscle mechanoreflex. , 2003, American journal of physiology. Heart and circulatory physiology.

[5]  M. Herr,et al.  Sympathetic discharge and vascular resistance after bed rest. , 1998, Journal of applied physiology.

[6]  R. Zelis,et al.  Enhanced maximal metabolic vasodilatation in the dominant forearms of tennis players. , 1986, Journal of applied physiology.

[7]  D. Kimmerly,et al.  Gender affects sympathetic and hemodynamic response to postural stress. , 2001, American journal of physiology. Heart and circulatory physiology.

[8]  M. Herr,et al.  Changes of elastic properties of central arteries during acute static exercise and lower body negative pressure , 2008, European Journal of Applied Physiology.

[9]  Eric A. Vittoz,et al.  Crystal oscillators , 1995 .

[10]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[11]  Y. Fung,et al.  Mechanics of the Circulation , 2011, Developments in Cardiovascular Medicine.

[12]  B. Parker,et al.  Sex differences in leg vasodilation during graded knee extensor exercise in young adults. , 2007, Journal of applied physiology.

[13]  W. Graham Richards,et al.  Art of electronics , 1983, Nature.

[14]  J. Shoemaker,et al.  Blood flow dynamics in heart failure. , 1999, Circulation.

[15]  M. Herr,et al.  Effects of transmural pressure on brachial artery mean blood velocity dynamics in humans. , 2002, Journal of applied physiology.

[16]  K. Pyke,et al.  Are the dynamic response characteristics of brachial artery flow-mediated dilation sensitive to the magnitude of increase in shear stimulus? , 2008, Journal of applied physiology.

[17]  G. Ludwig,et al.  The Velocity of Sound through Tissues and the Acoustic Impedance of Tissues , 1950 .

[18]  Xavier Sevillano,et al.  Sampling of continuous-time signals , 2010 .

[19]  A. Kunselman,et al.  Aging and the Exercise Pressor Reflex in Humans , 2003, Circulation.

[20]  M. Herr,et al.  Effects of age on brachial artery myogenic responses in humans. , 2004, American journal of physiology. Regulatory, integrative and comparative physiology.

[21]  Paul Horowitz,et al.  The Art of Electronics , 1980 .

[22]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.

[23]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[24]  S Prophet,et al.  Characteristics of Flow‐Mediated Brachial Artery Vasodilation in Human Subjects , 1989, Circulation research.

[25]  L. Sinoway,et al.  Effects of supplemental oxygen on forearm vasodilation in humans. , 1997, Journal of applied physiology.