Stochastic Local Search for the Direct Aperture Optimisation Problem

Abstract Intensity modulated radiation therapy (IMRT) is a widely applied cancer treatment technique that aims at effectively deliver radiation to cancerous cells while sparing surrounding healthy tissues. To this end, the radiation coming from a linear accelerator is modulated using a physical device called multi-leaf collimator. Traditionally, a sequential approach is applied to generate treatment plans in IMRT. In this approach, the optimal intensities for each beam angle are computed (Fluence Map Optimisation, FMO), and then a sequencing problem is solved to obtain the collimator setup (aperture shapes) required to achieve the intensities computed for the FMO problem. The sequencing step is critical as the treatment plans computed to solve the FMO problem are not clinically acceptable. Unfortunately, treatment plans obtained by the sequencing step are severely impaired w.r.t. those obtained in the FMO step. One approach that aims to deal with the problem described above is the Direct Aperture Optimisation (DAO) approach. The DAO problem aims at simultaneously determining deliverable aperture shapes and a set of radiation intensities. This approach considers both physical and delivery time constraints, allowing to generate clinically acceptable treatment plans. In this paper, we propose a stochastic local search algorithm to solve the DAO problem. Our approach alternates the search between two neighbourhood definitions; the first focused on the fluence map (intensities) and the second on the aperture shapes. We analyse the algorithmic components, parameters, and overall results obtained by our algorithm on a set of clinical prostate cancer cases. We compare the obtained treatment plans to the ones obtained by the traditional two-step approach. Results show that our algorithm is able to find deliverable treatment plans without major impairments in treatment plans quality.

[1]  Ke Sheng,et al.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation , 2017, Medical physics.

[2]  Joseph O Deasy,et al.  CERR: a computational environment for radiotherapy research. , 2003, Medical physics.

[3]  Uwe Oelfke,et al.  Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time. , 2015, Medical physics.

[4]  Horst W. Hamacher,et al.  Mathematical optimization in intensity modulated radiation therapy , 2010, Ann. Oper. Res..

[5]  Matthias Ehrgott,et al.  A matheuristic approach to solve the multiobjective beam angle optimization problem in intensity-modulated radiation therapy , 2018, Int. Trans. Oper. Res..

[6]  Horst W. Hamacher,et al.  Minimizing the number of apertures in multileaf collimator sequencing with field splitting , 2018, Discret. Appl. Math..

[7]  Daniel Dajun Zeng,et al.  Evolutionary dynamics of cryptocurrency transaction networks: An empirical study , 2018, PloS one.

[8]  Eugene Wong,et al.  A fast inverse direct aperture optimization algorithm for intensity‐modulated radiation therapy , 2019, Medical physics.

[9]  H. Mahmoudzadeh,et al.  TH-A-116-05: A Robust Direct Aperture Optimization Approach for Left-Sided Breast IMRT. , 2013, Medical physics.

[10]  C. Cotrutz,et al.  Segment-based dose optimization using a genetic algorithm. , 2003, Physics in medicine and biology.

[11]  Karl Otto,et al.  Direct aperture optimization for IMRT using Monte Carlo generated beamlets. , 2006, Medical physics.

[12]  R. Ahuja,et al.  A network flow algorithm to minimize beam-on time for unconstrained multileaf collimator problems in cancer radiation therapy , 2005 .

[13]  Gerhard J. Woeginger,et al.  Decomposition of integer matrices and multileaf collimator sequencing , 2005, Discret. Appl. Math..

[14]  Cedric X. Yu,et al.  Jaws-only IMRT using direct aperture optimization. , 2006, Medical physics.

[15]  Hao Gao,et al.  Rapid direct aperture optimization via dose influence matrix based piecewise aperture dose model , 2018, PloS one.

[16]  Matthias Ehrgott,et al.  Pareto local search algorithms for the multi-objective beam angle optimisation problem , 2018, J. Heuristics.

[17]  Stephen Jones,et al.  Clinical evaluation of direct aperture optimization when applied to head-and-neck IMRT. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[18]  Katia Parodi,et al.  Development of the open‐source dose calculation and optimization toolkit matRad , 2017, Medical physics.

[19]  Thomas Stützle,et al.  Stochastic Local Search Algorithms: An Overview , 2015, Handbook of Computational Intelligence.

[20]  Leslie Pérez Cáceres,et al.  The irace package: Iterated racing for automatic algorithm configuration , 2016 .

[21]  Steve B. Jiang,et al.  GPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy , 2010, Physics in medicine and biology.

[22]  Konrad Engel,et al.  A new algorithm for optimal multileaf collimator field segmentation , 2005, Discret. Appl. Math..

[23]  Franklin Johnson,et al.  Comparing Local Search Algorithms for the Beam Angles Selection in Radiotherapy , 2018, IEEE Access.

[24]  D M Shepard,et al.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. , 2002, Medical physics.

[25]  Michael C. Ferris,et al.  Optimizing the Delivery of Radiation Therapy to Cancer Patients , 1999, SIAM Rev..

[26]  Horst W. Hamacher,et al.  Minimizing beam‐on time in cancer radiation treatment using multileaf collimators , 2004, Networks.

[27]  Ehsan Salari,et al.  A column-generation-based method for multi-criteria direct aperture optimization , 2013, Physics in medicine and biology.

[28]  Franklin Johnson,et al.  Local Search Algorithms for the Beam Angles’ Selection Problem in Radiotherapy , 2018 .

[29]  Jie Yang,et al.  The Aperture Shape Optimization Based on Fuzzy Enhancement , 2018, IEEE Access.

[30]  M. Broderick,et al.  Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans , 2009, Radiation oncology.

[31]  Eugene Wong,et al.  Technical Note: A fast inverse direct aperture optimization algorithm for volumetric-modulated arc therapy. , 2020, Medical physics.

[32]  Arvind Kumar,et al.  A Column Generation Approach to Radiation Therapy Treatment Planning Using Aperture Modulation , 2005, SIAM J. Optim..

[33]  Abhishek Gupta,et al.  Optimization Algorithms Combining (Meta)heuristics and Mathematical Programming and Its Application in Engineering , 2018, Mathematical Problems in Engineering.

[34]  J. M. Dias,et al.  Discretization of optimal beamlet intensities in IMRT: A binary integer programming approach , 2012, Math. Comput. Model..

[35]  J Unkelbach,et al.  SU-E-T-656: Multi-Criteria Direct Aperture Optimization. , 2013, Medical physics.

[36]  C Clifton Ling,et al.  EUD but not QED. , 2002, International journal of radiation oncology, biology, physics.

[37]  Tiago Ventura,et al.  Beam angle optimization in IMRT: are we really optimizing what matters? , 2018, Int. Trans. Oper. Res..