Biotinylated steroid derivatives as ligands for biospecific interaction analysis with monoclonal antibodies using immunosensor devices.

Systematic ligand-binding studies of the biospecific interaction between steroids and antisteroid antibodies can be performed in real time using biosensor techniques. In this study, quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) biosensor systems were applied. Different biotinylated testosterone (T) and 17beta-estradiol (E2) derivatives were preincubated with streptavidin and immobilized on the sensor surfaces. We obtained low matrix densities of antigen enabling the investigation of the binding kinetics and position specificities of various anti-E2 and anti-T monoclonal antibodies (mAbs) to these steroidal compounds. The highest immunoreactivity of anti-E2 and anti-T mAbs is not necessarily for the specific modified steroid that was used as a protein-coupled hapten for immunization. The kinetic data confirm that both 3- and 19-specific anti-T mAbs do not discriminate between the 3- and 19-biotinylated T derivatives, whereas the 7alpha-biotinylated T probe showed no affinity to these two anti-T mAbs. In the case of the 3-specific anti-E2 mAb, comparable interaction data were found for 3- and 6alpha-biotinylated E2 compounds. The 6-specific anti-E2 mAb showed comparable ligand binding, but a significant higher dissociation rate to the position-specific antigen. The QCM and SPR results correspond well to the data from cross-reactivity studies in solution as well as to enzyme immunoassay equilibrium measurements.

[1]  J. Gordon,et al.  The oscillation frequency of a quartz resonator in contact with liquid , 1985 .

[2]  Michael J. O'Brien,et al.  Molecular Recognition between Genetically Engineered Streptavidin and Surface-Bound Biotin , 1999 .

[3]  Bo Johnsson,et al.  A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands , 1990 .

[4]  E. Sackmann,et al.  Comparison of the QCM and the SPR method for surface studies and immunological applications , 1995 .

[5]  R. Schumacher Die Quarzmikrowaage: Eine neue Meßtechnik zur in‐situ‐Untersuchung des Phasengrenzbereiches fest/flüssig , 1990 .

[6]  H. Rohrer,et al.  Rastertunnelmikroskopische Beobachtung von spezifisch adsorbiertem Streptavidin auf Biotin-funktionalisierten, selbstorganisierten Monoschichten , 1991 .

[7]  G. Abraham Solid-Phase Radioimmunoassay of Estradiol-17β , 1969 .

[8]  S. Hauck,et al.  Quartz crystal microbalance (QCM) as a device for the screening of phage libraries. , 1999, Biosensors & bioelectronics.

[9]  R. Cattrall Chemical Sensors , 1997 .

[10]  G. Johansson,et al.  Capacitance measurements of antibody-antigen interactions in a flow system. , 1997, Analytical chemistry.

[11]  P. Luppa,et al.  Concepts for the syntheses of biotinylated steroids. Part I: testosterone derivatives as immunochemical probes. , 2000, Bioconjugate chemistry.

[12]  P. Luppa,et al.  6 alpha-biotinylated estrone: novel tracer in competitive chemiluminescence immunoassay of estrone in serum. , 1995, Clinical chemistry.

[13]  P. Woias,et al.  HIV serology using piezoelectric immunosensors , 1994 .

[14]  P. Luppa,et al.  7 alpha-Biotinylated testosterone derivatives as tracers for a competitive chemiluminescence immunoassay of testosterone in serum. , 1997, Clinical chemistry.

[15]  A. Plückthun,et al.  Model and simulation of multivalent binding to fixed ligands. , 1998, Analytical biochemistry.

[16]  G M Whitesides,et al.  On-line detection of nonspecific protein adsorption at artificial surfaces. , 1997, Analytical chemistry.

[17]  J. Therasse,et al.  Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis. , 1998, Biosensors & bioelectronics.

[18]  Ernst Meyer Mechanization of Chemical Documentation , 1965 .

[19]  B. Liedberg,et al.  Principles of biosensing with an extended coupling matrix and surface plasmon resonance , 1993 .

[20]  L. Nieba,et al.  Competition BIAcore for measuring true affinities: large differences from values determined from binding kinetics. , 1996, Analytical biochemistry.

[21]  Magnus Malmqvist,et al.  Biospecific interaction analysis using biosensor technology , 1993, Nature.

[22]  J. Gebler,et al.  Immunoassay reagents for thyroid testing. 2. Binding properties and energetic parameters of a T4 monoclonal antibody and its Fab fragment with a library of thyroxine analog biosensors using surface plasmon resonance. , 1997, Bioconjugate chemistry.

[23]  C P Price,et al.  Immunosensors: technology and opportunities in laboratory medicine. , 1996, Clinical chemistry.

[24]  R K Craig,et al.  Methods in molecular medicine. , 1987, British medical journal.

[25]  D. Altschuh,et al.  Measurement of antigen–antibody interactions with biosensors , 1998, Journal of molecular recognition : JMR.

[26]  M. Malmqvist,et al.  BIACORE: an affinity biosensor system for characterization of biomolecular interactions. , 1999, Biochemical Society transactions.

[27]  C. Lyttle,et al.  Estrogen Receptor Ligands Modulate Its Interaction with DNA* , 1997, The Journal of Biological Chemistry.

[28]  J. Gallop,et al.  Kinetics of biomolecular interactions , 1997 .