Magnetic induction tomography methods and applications: a review

Magnetic induction tomography (MIT) is a tomographic technique capable of imaging the passive electromagnetic properties of an object. It has the advantages of being contact-less and non-invasive, as the process involves interrogating the electromagnetic field of the imaging subject. As such, the potential applications of MIT are broad, with various domains of operation including biomedicine, industrial process tomography and non-destructive evaluation. Consequently, there is a rich—yet underexplored—research landscape for the practical applications of MIT. The aim of this review is to provide a non-exhaustive overview of this landscape. The fundamental principles of MIT are discussed, alongside the instrumentation and techniques necessary to obtain and interpret MIT measurements.

[1]  Hermann Scharfetter,et al.  Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy). , 2003, Physiological measurement.

[2]  D W Armitage,et al.  Calculation of the forward problem for absolute image reconstruction in MIT. , 2008, Physiological measurement.

[3]  Manuchehr Soleimani,et al.  Dual modality ECT–MIT multi-phase flow imaging , 2015 .

[4]  M. S. Beck,et al.  Imaging system based on electromagnetic tomography (EMT) , 1993 .

[5]  Guglielmo Rubinacci,et al.  Solution of three dimensional eddy current problems by integral and differential methods , 1988 .

[6]  K. Preis,et al.  An edge finite element eddy current formulation using a reduced magnetic and a current vector potential , 2000 .

[7]  Nevzat G. Gencer,et al.  Electrical conductivity imaging via contactless measurements , 1999, IEEE Transactions on Medical Imaging.

[8]  Manuchehr Soleimani,et al.  Forward problem in 3D magnetic induction tomography (MIT) , 2003 .

[9]  Wim De Waele,et al.  Optical measurement of target displacement and velocity in bird strike simulation experiments , 2003 .

[10]  H. Igarashi,et al.  On convergence of ICCG applied to finite-element equation for quasi-static fields , 2002 .

[11]  A. Kameari,et al.  Three Dimensional Eddy Current Calculation Using Edge Elements for Magnetic Vector Potential , 1989 .

[12]  E. M. Freeman,et al.  A method of computing the sensitivity of electromagnetic quantities to changes in materials and sources , 1994 .

[13]  Nevzat G. Gencer,et al.  Low-Frequency Magnetic Subsurface Imaging: Reconstructing Conductivity Images of Biological Tissues via Magnetic Measurements , 2009, IEEE Transactions on Medical Imaging.

[14]  H Scharfetter,et al.  A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration. , 2006, Physiological measurement.

[15]  Huw Griffiths,et al.  Parallelization methods for implementation of a magnetic induction tomography forward model in symmetric multiprocessor systems , 2008, Parallel Comput..

[16]  Ming Yan,et al.  Imaging hemorrhagic stroke with magnetic induction tomography: realistic simulation and evaluation. , 2010, Physiological measurement.

[17]  D Gürsoy,et al.  Reconstruction artefacts in magnetic induction tomography due to patient's movement during data acquisition , 2009, Physiological measurement.

[18]  H. Griffiths Magnetic induction tomography , 2001 .

[19]  Manuchehr Soleimani,et al.  Two-phase low conductivity flow imaging using magnetic induction tomography , 2012 .

[20]  Daniel Watzenig,et al.  Reconstruction of inhomogeneities in fluids by means of capacitance tomography , 2003 .

[21]  M. Soleimani,et al.  FOUR DIMENSIONAL RECONSTRUCTION USING MA- GNETIC INDUCTION TOMOGRAPHY: EXPERIMEN- TAL STUDY , 2012 .

[22]  Manuchehr Soleimani,et al.  Planar magnetic induction tomography for 3D near subsurface imaging , 2013 .

[23]  Andrew Hunt Weighing without Touching: Applying Electrical Capacitance Tomography to Mass Flowrate Measurement in Multiphase Flows , 2014 .

[24]  A. J. Peyton,et al.  Feasibility Study of Planar-Array Electromagnetic Inductance Tomography (EMT) , 1999 .

[25]  Hermann Scharfetter,et al.  Single-Step 3-D Image Reconstruction in Magnetic Induction Tomography: Theoretical Limits of Spatial Resolution and Contrast to Noise Ratio , 2006, Annals of Biomedical Engineering.

[26]  Hermann Scharfetter,et al.  A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT). , 2005, Physiological measurement.

[27]  M. Soleimani,et al.  Improving the Temporal Resolution of Magnetic Induction Tomography for Molten Metal Flow Visualization , 2010, IEEE Transactions on Instrumentation and Measurement.

[28]  Theodoros D. Tsiboukis,et al.  3D eddy current computation with edge elements in terms of the electric intensity , 1998 .

[29]  Jian Guo Zhang,et al.  Application of Electrical Resistance Tomography to Ice-Water Two-Phase Flow Parameters Measurement , 2013 .

[30]  H Griffiths,et al.  A magnetic induction tomography system for samples with conductivities below 10 S m−1 , 2008 .

[31]  A. Peyton,et al.  Improvement of signal to noise ratio and frame capture rate in magnetic inductance tomography (MIT) by exploiting transient process analysis , 2009, 2009 IEEE International Workshop on Imaging Systems and Techniques.

[32]  H Griffiths,et al.  Frequency downconversion and phase noise in MIT. , 2002, Physiological measurement.

[33]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[34]  H Scharfetter,et al.  Anisotropic conductivity tensor imaging using magnetic induction tomography , 2010, Physiological measurement.

[35]  Ze Liu,et al.  Simulation study of the sensing field in electromagnetic tomography for two-phase flow measurement , 2005 .

[36]  Wuqiang Yang,et al.  An image-reconstruction algorithm based on Landweber's iteration method for electrical-capacitance tomography , 1999 .

[37]  N. G. Gencer,et al.  Forward problem solution for electrical conductivity imaging via contactless measurements. , 1999, Physics in medicine and biology.

[38]  H. Griffiths,et al.  A transceiver for direct phase measurement magnetic induction tomography , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[39]  H. C. Wee,et al.  A Magnetic Induction Tomography system with sub-millidegree phase noise and high long-term phase stability , 2009 .

[40]  Sazali Yaacob,et al.  Advancements in Transmitters and Sensors for Biological Tissue Imaging in Magnetic Induction Tomography , 2012, Sensors.

[41]  Wang Bao-shou Research on void fraction of gas-liquid two-phase flow based on COMSOL , 2013 .

[42]  Patricia Brunner,et al.  Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography , 2006, Physiological measurement.

[43]  Anthony J. Peyton,et al.  Performance of a FPGA-based Direct Digitising Signal Measurement module for MIT , 2010 .

[44]  Maurice Beck,et al.  Developments in electro-magnetic tomography instrumentation , 1996 .

[46]  Branko M. Kolundzija,et al.  Electromagnetic modeling of composite metallic and dielectric structures , 1999 .

[47]  A. Peyton,et al.  Imaging the continuous conductivity profile within layered metal structures using inductance spectroscopy , 2005, IEEE Sensors Journal.

[48]  Ryszard Palka,et al.  Solution of three dimensional inverse problem of magnetic induction tomography using Tikhonov regularization method , 2009 .

[49]  N. H. Saunders,et al.  A feasibility study of in vivo electromagnetic imaging. , 1993, Physics in medicine and biology.

[50]  A new imaging approach for in situ and ex situ inspections of conductive fiber–reinforced composites by magnetic induction tomography , 2014 .

[51]  H Griffiths,et al.  Magnetic Induction Tomography: A Measuring System for Biological Tissues , 1999, Annals of the New York Academy of Sciences.

[52]  Xiandong Ma,et al.  Hardware and software design for an electromagnetic induction tomography (EMT) system for high contrast metal process applications , 2005 .

[53]  Wuliang Yin,et al.  A planar EMT system for the detection of faults on thin metallic plates , 2006 .

[54]  Vladimir A. Cherepenin,et al.  Progress in Realization of Magnetic Induction Tomography , 1999 .

[55]  Xiandong Ma,et al.  Development of multiple frequency electromagnetic induction systems for steel flow visualization , 2008 .

[56]  A Korjenevsky,et al.  Magnetic induction tomography: experimental realization. , 2000, Physiological measurement.

[57]  Manuchehr Soleimani,et al.  Pipeline inspection using magnetic induction tomographybased on a narrowband pass filtering method , 2012 .

[58]  H Griffiths,et al.  A highly phase-stable differential detector amplifier for magnetic induction tomography. , 2011, Physiological measurement.

[59]  H. Lackner,et al.  Magnetic induction tomography: hardware for multi-frequency measurements in biological tissues. , 2001, Physiological measurement.

[60]  B. T. Hjertaker,et al.  Three-phase flow measurement in the petroleum industry , 2012 .

[61]  V. Thomée Galerkin Finite Element Methods for Parabolic Problems (Springer Series in Computational Mathematics) , 2010 .

[62]  Manuchehr Soleimani,et al.  Experimental evaluation of conductive flow imaging using magnetic induction tomography , 2015 .

[63]  Lu Ma,et al.  Electromagnetic imaging for internal and external inspection of metallic pipes , 2012 .

[64]  M. K. Pandit,et al.  Nonlinear static analysis of smart laminated composite plate , 2011 .

[65]  Doga Gursoy,et al.  Imaging artifacts in magnetic induction tomography caused by the structural incorrectness of the sensor model , 2011 .

[66]  Nevzat G. Gencer,et al.  A new 3D FEM formulation for the solution of potential fields in magnetic induction problems , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[67]  K. Preis,et al.  Calculation of 3D eddy current problems by finite element method using either an electric or a magnetic vector potential , 1988 .

[68]  Manuchehr Soleimani,et al.  Hardware and software design for a National Instrument-based magnetic induction tomography system for prospective biomedical applications. , 2012, Physiological measurement.

[69]  Hermann Scharfetter,et al.  Optimum Receiver Array Design for Magnetic Induction Tomography , 2009, IEEE Transactions on Biomedical Engineering.

[70]  Lu Ma,et al.  Magnetic Induction Tomography with High Performance GPU Implementation , 2016 .

[71]  Manuchehr Soleimani,et al.  Hidden defect identification in carbon fibre reinforced polymer plates using magnetic induction tomography , 2014 .

[72]  Nevzat G. Gencer,et al.  Electrical conductivity imaging via contactless measurements: an experimental study , 2003, IEEE Transactions on Medical Imaging.

[73]  Hermann Scharfetter,et al.  Sensitivity maps for low-contrast perturbations within conducting background in magnetic induction tomography. , 2002, Physiological measurement.