High Voltage Ride through Control of PMSG-Based Wind Turbine Generation System Using Supercapacitor

Regarding PMSG-based wind turbine generation system, this paper proposes a supercapacitor energy storage unit (SCESU) which is connected in parallel with the DC-link of the back-to-back converter to enhance its high voltage ride through performance. The analysis of the operation and control for the grid-side converter and SCESU are conducted. Based on real time digital simulators (RTDS), a model and a Hardware-in-the-Loop (HiL) platform of PMSG-based wind turbine with SCESU is developed, and the simulation results show that the SCESU absorbs the imbalanced energy and the grid-side converter absorbs inductive reactive power during the period of voltage swell and verify the correctness and feasibility of the high voltage ride through control strategy.

[1]  C. Feltes,et al.  High voltage ride-through of DFIG-based wind turbines , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[2]  Fangfang Shi,et al.  An integrated control strategy of PMSG-based wind turbine generation system to improve its fault ride-through capability by using an energy storage device , 2015 .

[3]  Xie Xu Cause and Countermeasure Analysis on Wind Turbines' Trip-off from Grid , 2011 .

[4]  P. Student,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG during Voltage Sag and Swell , 2014 .

[5]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[6]  Xing Zhang,et al.  Grid fault ride through of a medium-voltage three-level full power wind power converter , 2016, 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia).

[7]  A. Abu-Siada,et al.  Application of STATCOM to improve the high-voltage-ride-through capability of wind turbine generator , 2011, 2011 IEEE PES Innovative Smart Grid Technologies.

[8]  Gengyin Li,et al.  Power coordinated control of wind turbines with permanent magnet synchronous generator for low voltage ride through , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[9]  Zhang Xing A Coordinated Control Strategy for Low Voltage Ride-Though of Direct-Drive Permanent Magnet Wind Power Generating Units , 2013 .

[10]  Mansour Mohseni,et al.  Low and high voltage ride-through of DFIG wind turbines using hybrid current controlled converters , 2011 .

[11]  F.W. Fuchs,et al.  High voltage ride through with FACTS for DFIG based wind turbines , 2009, 2009 13th European Conference on Power Electronics and Applications.

[12]  Changxian Liu,et al.  High voltage ride-through of grid-side converter for PMSG based directly driven wind turbines , 2016, CCC 2016.

[13]  Yao Zhao,et al.  Simulation research on fault ride through for permanent magnet synchronous generator wind power system , 2014, 2014 9th IEEE Conference on Industrial Electronics and Applications.