23 . 3 : Tactile Sensor Based on Piezoelectric

We discuss here about the realization of tactile sensor based on the principle of change in piezoelectric resonance frequency with the applied pressure. An array of electrodes has been adopted on either side of the PZT material to have independent resonators. The common areas sandwiched between the electrodes and excitable at resonance frequency of the PZT material are used to form the sensitive area of the tactile sensor. The electrodes were deposited using sputtering technique. Tactile sensors with 3x3, 7x7 and 15x15 array of electrodes are developed with different electrode dimensions and separation between the electrodes. The tactile sensor has been interfaced to computer for the convenience of automatic scanning and making it more user interactive. The tactile sensors developed with diflerent spatial resolution were tested for diferent shaped objects placed in contact with the sensor. The 3x3 matrix tactile sensor showed relatively poor spatial resolution whereas I.5xlS-matrix tactile sensor showed improved spatial resolution. The sensor with 7x7 matrix elements was tested for its sensitivity to different extents of applied force/pressure. The output response study carried out on the sensors indicated that these sensors can provide information not only about the extent of force/pressure applied on the object, but also the contour of the object which is in contact with the sensor.