Analysis on Anti-Grid Voltage Disturbance Capacity of Phase-Shifted Full-Bridge ZVS DC/DC Converter

Based on the background of battery charging system, in this paper, the small-signal equivalent circuit model of phase-shifted full-bridge ZVS DC/DC converter is established, then its transfer function is derived, and a single closed-loop voltage-mode controller is designed. In order to analyze anti-grid voltage disturbance capacity, transfer function of audio susceptibility is presented, and the anti-grid disturbance capacity in open-loop system and single closed-loop system is analyzed in theory and is verified by simulation respectively.

[1]  Zoran Mihajlovic,et al.  Output ripple analysis of switching DC-DC converters , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[2]  B. Lehman,et al.  Output ripple analysis of switching DC-DC converters , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.

[3]  D. C. Hamill Generalized small-signal dynamical modeling of multi-port DC-DC converters , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.