A microfluidic cardiac flow profile generator for studying the effect of shear stress on valvular endothelial cells.

To precisely investigate the mechanobiological responses of valvular endothelial cells, we developed a microfluidic flow profile generator using a pneumatically-actuated micropump consisting of microvalves of various sizes. By controlling the closing pressures and the actuation times of these microvalves, we modulated the magnitude and frequency of the shear stress to mimic mitral and aortic inflow profiles with frequencies in the range of 0.8-2 Hz and shear stresses up to 20 dyn cm-2. To demonstrate this flow profile generator, aortic inflow with an average of 5.9 dyn cm-2 shear stress at a frequency of 1.2 Hz with a Reynolds number of 2.75, a Womersley number of 0.27, and an oscillatory shear index (OSI) value of 0.2 was applied to porcine aortic valvular endothelial cells (PAVECs) for mechanobiological studies. The cell alignment, cell elongation, and alpha-smooth muscle actin (αSMA) expression of PAVECs under perfusion, steady flow, and aortic inflow conditions were analyzed to determine their shear-induced cell migration and trans-differentiation. In this morphological and immunocytochemical study, we found that the PAVECs elongated and aligned themselves perpendicular to the directions of the steady flow and the aortic inflow. In contrast, under perfusion with a fluidic shear stress of 0.47 dyn cm-2, the PAVECs elongated and aligned themselves parallel to the direction of flow. The PAVECs exposed to the aortic inflow upregulated their αSMA-protein expression to a greater degree than those exposed to perfusion and steady flow. By comparing these results to those of previous studies of pulsatile flow, we also found that the ratio of positive to negative shear stress plays an important role in determining PAVECs' trans-differentiation and adaptation to flow. This microfluidic cardiac flow profile generator will enable future valvular mechanobiological studies to determine the roles of magnitude and frequency of shear stresses.

[1]  P. Lelkes,et al.  Gene expression profiling of human aortic endothelial cells exposed to disturbed flow and steady laminar flow. , 2002, Physiological genomics.

[2]  R. Lal,et al.  Shear stress-induced reorganization of the surface topography of living endothelial cells imaged by atomic force microscopy. , 1994, Circulation research.

[3]  D. Berman,et al.  Predictive Value of Age- and Sex-Specific Nomograms of Global Plaque Burden on Coronary Computed Tomography Angiography for Major Cardiac Events , 2017, Circulation Cardiovascular Imaging.

[4]  Santanu Chandra,et al.  Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease , 2012, Biomechanics and modeling in mechanobiology.

[5]  Takehiko Kitamori,et al.  A micro-spherical heart pump powered by cultured cardiomyocytes. , 2007, Lab on a chip.

[6]  S. Kozerke,et al.  Shear-scaling-based approach for irreversible energy loss estimation in stenotic aortic flow - An in vitro study. , 2017, Journal of biomechanics.

[7]  Robert M Nerem,et al.  Valvular endothelial cells and the mechanoregulation of valvular pathology , 2007, Philosophical Transactions of the Royal Society B: Biological Sciences.

[8]  A. Yoganathan,et al.  Experimental measurement of dynamic fluid shear stress on the aortic surface of the aortic valve leaflet , 2011, Biomechanics and Modeling in Mechanobiology.

[9]  Gretchen J. Mahler,et al.  Effects of shear stress pattern and magnitude on mesenchymal transformation and invasion of aortic valve endothelial cells , 2014, Biotechnology and bioengineering.

[10]  Robert M. Nerem,et al.  Transcriptional Profiles of Valvular and Vascular Endothelial Cells Reveal Phenotypic Differences: Influence of Shear Stress , 2006, Arteriosclerosis, thrombosis, and vascular biology.

[11]  Sukho Park,et al.  Micro pumping with cardiomyocyte-polymer hybrid. , 2007, Lab on a chip.

[12]  John E. Hall,et al.  Guyton and Hall Textbook of Medical Physiology , 2015 .

[13]  Joohyung Lee,et al.  Biomimetic Cardiac Microsystems for Pathophysiological Studies and Drug Screens , 2015, Journal of laboratory automation.

[14]  R M Nerem,et al.  Oscillatory shear stress stimulates adhesion molecule expression in cultured human endothelium. , 1998, Circulation research.

[15]  Craig A Simmons,et al.  Macro- and microscale fluid flow systems for endothelial cell biology. , 2010, Lab on a chip.

[16]  Yoshitaka J. Sei,et al.  Detection of frequency-dependent endothelial response to oscillatory shear stress using a microfluidic transcellular monitor , 2017, Scientific Reports.

[17]  Erik C Jensen,et al.  Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer. , 2013, Analytical chemistry.

[18]  Joohyung Lee,et al.  Phenotype Transformation of Aortic Valve Interstitial Cells Due to Applied Shear Stresses Within a Microfluidic Chip , 2017, Annals of Biomedical Engineering.

[19]  Robert M Nerem,et al.  Unique Morphology and Focal Adhesion Development of Valvular Endothelial Cells in Static and Fluid Flow Environments , 2004, Arteriosclerosis, thrombosis, and vascular biology.

[20]  Ajit P Yoganathan,et al.  Altered Shear Stress Stimulates Upregulation of Endothelial VCAM-1 and ICAM-1 in a BMP-4– and TGF-&bgr;1–Dependent Pathway , 2009, Arteriosclerosis, thrombosis, and vascular biology.

[21]  C. Simmons,et al.  Matrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels. , 2007, Lab on a chip.

[22]  T. Ohashi,et al.  Effects of frequency of pulsatile flow on morphology and integrin expression of vascular endothelial cells. , 2007, Technology and health care : official journal of the European Society for Engineering and Medicine.

[23]  Dana Sherman,et al.  Doctor of philosophy , 2018, Canadian Medical Association Journal.

[24]  J. Koenderink Q… , 2014, Les noms officiels des communes de Wallonie, de Bruxelles-Capitale et de la communaute germanophone.

[25]  Robert M Nerem,et al.  Valvular endothelial cells regulate the phenotype of interstitial cells in co-culture: effects of steady shear stress. , 2006, Tissue engineering.

[26]  Peter Oshkai,et al.  The influence of the aortic root geometry on flow characteristics of a prosthetic heart valve. , 2015, Journal of biomechanical engineering.

[27]  Craig A Simmons,et al.  Cell–Matrix Interactions in the Pathobiology of Calcific Aortic Valve Disease: Critical Roles for Matricellular, Matricrine, and Matrix Mechanics Cues , 2011, Circulation research.

[28]  Gary Rosengarten,et al.  Cardiac-like flow generator for long-term imaging of endothelial cell responses to circulatory pulsatile flow at microscale. , 2013, Lab on a chip.

[29]  Shuichi Takayama,et al.  Computer-controlled microcirculatory support system for endothelial cell culture and shearing. , 2005, Analytical chemistry.

[30]  Santanu Chandra,et al.  Ex Vivo Evidence for the Contribution of Hemodynamic Shear Stress Abnormalities to the Early Pathogenesis of Calcific Bicuspid Aortic Valve Disease , 2012, PloS one.

[31]  P. Lelkes,et al.  Gene expression profiling of vascular endothelial cells exposed to fluid mechanical forces: relevance for focal susceptibility to atherosclerosis. , 2004, Endothelium : journal of endothelial cell research.

[32]  T. Gasser,et al.  Biomechanical factors in the biology of aortic wall and aortic valve diseases , 2013, Cardiovascular research.

[33]  William H. Grover,et al.  Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices , 2003 .

[34]  Takehiko Kitamori,et al.  An actuated pump on-chip powered by cultured cardiomyocytes. , 2006, Lab on a chip.

[35]  Heterogeneous Susceptibility of Valve Endothelial Cells to Mesenchymal Transformation in Response to TNFα , 2013, Annals of Biomedical Engineering.

[36]  S. Chien,et al.  Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives. , 2011, Physiological reviews.

[37]  B. Hinz,et al.  Alpha-smooth muscle actin expression upregulates fibroblast contractile activity. , 2001, Molecular biology of the cell.

[38]  Integrins and cadherins join forces to form adhesive networks , 2011, Journal of Cell Science.

[39]  T. Marwick,et al.  Assessment of diastolic function: what the general cardiologist needs to know , 2005, Heart.