Open-Ended Coaxial Probe: Model Limitations

We propose a procedure to determine the validity range of any empirical model of the open-ended coaxial probe transition that is used to measure the permittivity of materials. The procedure is illustrated by an application of the method to a standard coaxial cable probe, a permittivity range of interest in the food industry and, as an empirical model, the well-known "lumped capacitor model".

[1]  Kun-mu Chen,et al.  Determination of electromagnetic properties of materials using flanged open-ended coaxial probe-full-wave analysis , 1995 .

[2]  M. Cassettari,et al.  The dielectric properties of alcohols–water solutions. I. The alcohol rich region , 1983 .

[3]  S. Yagihara,et al.  The dielectric relaxation of mixtures of water and primary alcohol , 1989 .

[4]  C. Gabriel,et al.  Admittance models for open ended coaxial probes and their place in dielectric spectroscopy. , 1994, Physics in medicine and biology.

[5]  P. Domich,et al.  Analysis of an open-ended coaxial probe with lift-off for nondestructive testing , 1994 .

[6]  Chih-Wei Chang,et al.  Nondestructive determination of electromagnetic parameters of dielectric materials at X-band frequencies using a waveguide probe system , 1997 .

[7]  Antoni Broquetas,et al.  Analysis and reduction of the distortions induced by time-domain filtering techniques in network analyzers , 1998, IEEE Trans. Instrum. Meas..

[8]  M. Decréton,et al.  Nondestructive Measurement of Complex Permittivity for Dielectric Slabs (Short Papers) , 1975 .

[9]  T. E. Hodgetts,et al.  Comparison of three numerical treatments for the open-ended coaxial line sensor , 1990 .

[10]  W. Press,et al.  Numerical Recipes in Fortran: The Art of Scientific Computing.@@@Numerical Recipes in C: The Art of Scientific Computing. , 1994 .

[11]  William H. Press,et al.  Book-Review - Numerical Recipes in Pascal - the Art of Scientific Computing , 1989 .

[12]  James Baker-Jarvis,et al.  Shielded open-circuited sample holder for dielectric measurements of solids and liquids , 1998, IEEE Trans. Instrum. Meas..

[13]  F. E. Gardiol,et al.  Reflection of an open-ended coaxial line and application to nondestructive measurement of materials , 1981, IEEE Transactions on Instrumentation and Measurement.

[14]  S. S. Stuchly,et al.  Analysis of the Open-Ended Coaxial Line Sensors , 1990 .

[15]  C. Pournaropoulos,et al.  A study on the coaxial aperture electromagnetic sensor and its application in material characterization , 1993, 1993 IEEE Instrumentation and Measurement Technology Conference.

[16]  Stanislaw S. Stuchly,et al.  Capacitance of Open-Ended Dielectric-Filled Coaxial Lines-Experimental Results , 1983, IEEE Transactions on Instrumentation and Measurement.

[17]  R. D. Pollard,et al.  An improved technique for permittivity measurements using a coaxial probe , 1997 .

[18]  Reza Zoughi,et al.  Multimode solution for the reflection properties of an open-ended rectangular waveguide radiating into a dielectric half-space: the forward and inverse problems , 1999, IEEE Trans. Instrum. Meas..

[19]  S. Evans,et al.  Intercomparison of dielectric reference materials available for the calibration of an open-ended probe at different temperatures , 1995 .

[20]  Kenneth R. Foster,et al.  Noninvasive electrical characterization of materials at microwave frequencies using an open-ended coaxial line: test of an improved calibration technique , 1990 .

[21]  Calibration of dielectric constant probes using salt solutions of unknown conductivity , 1996 .

[22]  D. K. Misra,et al.  A Quasi-Static Analysis of Open-Ended Coaxial Lines (Short Paper) , 1987 .

[23]  Devendra K. Misra,et al.  REVIEW ARTICLE: The co-axial aperture electromagnetic sensor and its application in material characterization , 1997 .

[24]  M. Cassettari,et al.  THE DIELECTRIC PROPERTIES OF ALCOHOL-WATER SOLUTIONS. I. THE ALCOHOL RICH REGION , 1983 .

[25]  Maria A. Stuchly,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part I , 1982 .

[26]  P. Broersen,et al.  Facts and fiction in spectral analysis , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[27]  C. Papas,et al.  Theory of the Circular Diffraction Antenna , 1951 .

[28]  L.L. Li,et al.  Flanged coaxial microwave probes for measuring thin moisture layers , 1992, IEEE Transactions on Biomedical Engineering.

[29]  L. Milne‐Thomson A Treatise on the Theory of Bessel Functions , 1945, Nature.

[30]  Stanislaw S. Stuchly,et al.  An Equivalent Circuit of an Open-Ended Coaxial Line , 1983, IEEE Transactions on Instrumentation and Measurement.

[31]  M. Stuchly,et al.  Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review , 1980, IEEE Transactions on Instrumentation and Measurement.

[33]  Fred E. Gardiol,et al.  Open-Ended Waveguides: Principles and Applications , 1985 .

[34]  T. E. Hodgetts,et al.  Dielectric measurements on reference liquids using automatic network analysers and calculable geometries , 1990 .

[35]  S. Jenkins,et al.  Use of open-ended coaxial line sensor with a laminar or liquid dielectric backed by a conducting plane , 1992 .