A new reconstruction strategy for image improvement in pinhole SPECT

Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90° and 45° relative to the object’s axis. This system satisfies Tuy’s condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99mTc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99mTc-hydroxymethylene diphosphonate. Feldkamp’s filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals.

[1]  Michel Defrise,et al.  Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study , 2000, European Journal of Nuclear Medicine.

[2]  James A. Sorenson,et al.  Instrumentation in nuclear medicine , 1967 .

[3]  A. P. Jeavons,et al.  A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998 .

[4]  G T Gullberg,et al.  A cone-beam tomography algorithm for orthogonal circle-and-line orbit. , 1992, Physics in medicine and biology.

[5]  Ulla Ruotsalainen,et al.  Accelerated median root prior reconstruction for pinhole single-photon emission tomography (SPET). , 2003, Physics in medicine and biology.

[6]  S. Cherry,et al.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. , 2003, Physics in medicine and biology.

[7]  A. Jeavons,et al.  A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[8]  Hiroshi Watabe,et al.  Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation. , 2003, Physics in medicine and biology.

[9]  Koichi Ogawa,et al.  Ultra high resolution pinhole SPECT for small animal study , 1998 .

[10]  Ronald J. Jaszczak,et al.  Analytic determination of the pinhole collimator's point-spread function and RMS resolution with penetration , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[11]  Hideo Onishi,et al.  Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: A simulation study , 2002, Annals of nuclear medicine.

[12]  H. Atkins,et al.  Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  Tsuneo Saito,et al.  Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits , 1994, IEEE Trans. Medical Imaging.

[14]  S R Meikle,et al.  Instrumentation and methodology for quantitative pre-clinical imaging studies. , 2001, Current pharmaceutical design.

[15]  Ronald J. Jaszczak,et al.  Helical pinhole SPECT for small-animal imaging: a method for addressing sampling completeness , 2003 .

[16]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[17]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[18]  Christian Kolbitsch,et al.  Evaluation of Striatal Dopamine Transporter Function in Rats by in Vivo β-[123I]CIT Pinhole SPECT , 2002, NeuroImage.

[19]  H. Kudo,et al.  Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography. , 1990, Journal of the Optical Society of America. A, Optics and image science.

[20]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[21]  Y. Yonekura,et al.  Ultra-high resolution SPECT system using four pinhole collimators for small animal studies. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[23]  Ronald J. Jaszczak,et al.  Analytic determination of pinhole collimator sensitivity with penetration , 2001, IEEE Transactions on Medical Imaging.

[24]  A. Chatziioannou PET scanners dedicated to molecular imaging of small animal models. , 2002, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[25]  R. Jaszczak,et al.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. , 1994, Physics in medicine and biology.

[26]  R J Jaszczak,et al.  A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation , 1994, Physics in medicine and biology.

[27]  R. Jaszczak,et al.  The effect of gamma ray penetration on angle-dependent sensitivity for pinhole collimation in nuclear medicine. , 1997, Medical physics.

[28]  Jurgen Seidel,et al.  Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability , 2001 .

[29]  Ulla Ruotsalainen,et al.  Pinhole single-photon emission tomography reconstruction based on median root prior , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[30]  H. Iida,et al.  Absolute quantitation of regional myocardial blood flow of rats using dynamic pinhole SPECT , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[31]  B F Hutton,et al.  Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT. , 1998, Physics in medicine and biology.