An efficient dose calculation strategy for intensity modulated proton therapy.

While intensity-modulated proton therapy (IMPT) has great potential to improve the therapeutic efficacy of radiotherapy, IMPT optimization can be computationally demanding, particularly for large and complex tumors. Here we propose a dose calculation strategy to accelerate IMPT optimization while reducing memory requirements. By using two adjustable threshold parameters, our method separates dose contributions from proton beamlets into major and minor components for each dose voxel. The optimization proceeds with two levels of iterations: in inner iterations, doses are updated in correspondence with changes in beamlet intensities from only the major contributions while keeping the portions from the minor contributions constant; in outer iterations, doses are recalculated exactly by considering both major and minor contributions. Since the number of elements in the influence matrix for major contributions is relatively small, each inner iteration proceeds quickly. Each outer iteration requires a longer computation time, but only a few such iterations are needed. Our study shows that the proposed strategy leads to nearly identical dose distributions as those optimized with the full influence matrix, but reducing computing time by at least a factor of 3 and internal memory requirements by a factor of 10 or more. In addition, we show that the proposed approach could enhance other optimization-related applications such as optimizing beam angles. By using an advanced lung cancer case that would demand large computing resources by conventional optimization approach, we show how our method may potentially help improve IMPT treatment planning in real clinical situations.

[1]  Robert Jeraj,et al.  The method of intercepts in parameter space for the analysis of local minima caused by dose-volume constraints. , 2003, Physics in medicine and biology.

[2]  R Mohan,et al.  Algorithms and functionality of an intensity modulated radiotherapy optimization system. , 2000, Medical physics.

[3]  U Oelfke,et al.  Relating two techniques for handling uncertainties in IMRT optimization , 2006, Physics in medicine and biology.

[4]  R Mohan,et al.  Intensity modulation optimization, lateral transport of radiation, and margins. , 1996, Medical physics.

[5]  H Edwin Romeijn,et al.  A fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation. , 2006, Medical physics.

[6]  Tinsu Pan,et al.  New Technologies in Radiation Oncology , 2008, Journal of Nuclear Medicine.

[7]  Radhe Mohan,et al.  A fast dose calculation method based on table lookup for IMRT optimization. , 2003, Physics in medicine and biology.

[8]  E. Pedroni,et al.  The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization. , 1995, Medical physics.

[9]  Stephen J. Wright,et al.  Efficient schemes for robust IMRT treatment planning , 2006, Physics in medicine and biology.

[10]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[11]  Y. Censor,et al.  A computational solution of the inverse problem in radiation-therapy treatment planning , 1988 .

[12]  T. Bortfeld IMRT: a review and preview , 2006, Physics in medicine and biology.

[13]  Radhe Mohan,et al.  Incorporating partial shining effects in proton pencil-beam dose calculation , 2008, Physics in medicine and biology.

[14]  Radhe Mohan,et al.  Intensity-modulated proton therapy reduces the dose to normal tissue compared with intensity-modulated radiation therapy or passive scattering proton therapy and enables individualized radical radiotherapy for extensive stage IIIB non-small-cell lung cancer: a virtual clinical study. , 2010, International journal of radiation oncology, biology, physics.

[15]  T. Bortfeld,et al.  Accelerating IMRT optimization by voxel sampling , 2007, Physics in medicine and biology.

[16]  Steve B Jiang,et al.  GPU-based ultra-fast dose calculation using a finite size pencil beam model. , 2009, Physics in medicine and biology.

[17]  Matthias Fippel,et al.  A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations , 2005, Physics in medicine and biology.

[18]  T Bortfeld,et al.  Optimized planning using physical objectives and constraints. , 1999, Seminars in radiation oncology.

[19]  A dose calculation method including scatter for IMRT optimization. , 2004, Physics in medicine and biology.

[20]  E Pedroni,et al.  Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams , 2005, Physics in medicine and biology.

[21]  John N Tsitsiklis,et al.  A robust approach to IMRT optimization , 2006, Physics in medicine and biology.

[22]  Radhe Mohan,et al.  MO‐D‐351‐04: A Hybrid Inverse Planning Algorithm of IMPT Optimization , 2008 .

[23]  M Goitein,et al.  A pencil beam algorithm for proton dose calculations. , 1996, Physics in medicine and biology.

[24]  T Kanai,et al.  Spot scanning system for proton radiotherapy. , 1980, Medical physics.

[25]  A. Lomax,et al.  Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.

[26]  S. Spirou,et al.  A gradient inverse planning algorithm with dose-volume constraints. , 1998, Medical physics.

[27]  Z Chen,et al.  The influence of scatter on the design of optimized intensity modulations. , 1995, Medical physics.

[28]  Lei Dong,et al.  Speed and convergence properties of gradient algorithms for optimization of IMRT. , 2004, Medical physics.

[29]  C. Allgower,et al.  Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking. , 2008, Medical physics.

[30]  Timothy C Y Chan,et al.  Accounting for range uncertainties in the optimization of intensity modulated proton therapy , 2007, Physics in medicine and biology.

[31]  Radhe Mohan,et al.  Experimental characterization of the low-dose envelope of spot scanning proton beams , 2010, Physics in medicine and biology.

[32]  R Mohan,et al.  Acceleration of dose calculations for intensity-modulated radiotherapy. , 2001, Medical physics.

[33]  Radhe Mohan,et al.  A novel patch-field design using an optimized grid filter for passively scattered proton beams , 2007, Physics in medicine and biology.