Airborne contaminants during controlled residential fires

ABSTRACT In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (post suppression) and on the fireground where personnel were operating without any respiratory protection. Personal air measurements were collected from firefighters assigned to fire attack, victim search, overhaul, outside ventilation, and command/pump operator positions. Two different fire attack tactics were conducted for the fires (6 interior and 6 transitional) and exposures were compared between the tactics. For each of the 12 fires, firefighters were paired up to conduct each job assignment, except for overhaul that was conducted by 4 firefighters. Sampled compounds included polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs, e.g., benzene), hydrogen cyanide (HCN), and particulate (area air sampling only). Median personal air concentrations for the attack and search firefighters were generally well above applicable short-term occupational exposure limits, with the exception of HCN measured from search firefighters. Area air concentrations of all measured compounds decreased after suppression. Personal air concentrations of total PAHs and benzene measured from some overhaul firefighters exceeded exposure limits. Median personal air concentrations of HCN (16,300 ppb) exceeded the exposure limit for outside vent firefighters, with maximum levels (72,900 ppb) higher than the immediately dangerous to life and health (IDLH) level. Median air concentrations on the fireground (including particle count) were above background levels and highest when collected downwind of the structure and when ground-level smoke was the heaviest. No statistically significant differences in personal air concentrations were found between the 2 attack tactics. The results underscore the importance of wearing self-contained breathing apparatus when conducting overhaul or outside ventilation activities. Firefighters should also try to establish command upwind of the structure fire, and if this cannot be done, respiratory protection should be considered.

[1]  P W Brandt-Rauf,et al.  Health hazards of fire fighters: exposure assessment. , 1988, British journal of industrial medicine.

[2]  Judith Eisenberg,et al.  Systemic Exposure to PAHs and Benzene in Firefighters Suppressing Controlled Structure Fires , 2014, The Annals of occupational hygiene.

[3]  F. Jongeneelen,et al.  Uptake of polycyclic aromatic hydrocarbons among trainers in a fire-fighting training facility. , 1997, American Industrial Hygiene Association journal.

[4]  U. Epa Dermal exposure assessment: Principles and applications , 1992 .

[5]  D. Ecobichon,et al.  CHARACTERIZATION OF VOLATILE ORGANIC COMPOUNDS IN SMOKE AT MUNICIPAL STRUCTURAL FIRES , 2001, Journal of toxicology and environmental health. Part A.

[6]  E. Somers International Agency for Research on Cancer. , 1985, CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne.

[7]  B. Gersh Emergency Duties and Deaths from Heart Disease among Firefighters in the United States , 2008 .

[8]  Kenneth W Fent,et al.  Assessing the risk to firefighters from chemical vapors and gases during vehicle fire suppression. , 2011, Journal of environmental monitoring : JEM.

[9]  Denise L. Smith,et al.  Sudden cardiac death in the fire service. , 2014, Occupational medicine.

[10]  Katherine M. Kirk,et al.  Firefighter Exposures to Airborne Contaminants during Extinguishment of Simulated Residential Room Fires , 2011 .

[11]  Katherine M Kirk,et al.  Firefighting Instructors’ Exposures to Polycyclic Aromatic Hydrocarbons During Live Fire Training Scenarios , 2015, Journal of occupational and environmental hygiene.

[12]  Richard M Kesler,et al.  Thermal response to firefighting activities in residential structure fires: impact of job assignment and suppression tactic , 2018, Ergonomics.

[13]  Stephen Kerber,et al.  Analysis of Changing Residential Fire Dynamics and Its Implications on Firefighter Operational Timeframes , 2012 .

[14]  Kathleen M Waters,et al.  Mortality and cancer incidence in a pooled cohort of US firefighters from San Francisco, Chicago and Philadelphia (1950–2009) , 2013, Occupational and Environmental Medicine.

[15]  J. Samet,et al.  Air Pollution and Cardiovascular Disease: A Statement for Healthcare Professionals From the Expert Panel on Population and Prevention Science of the American Heart Association , 2004, Circulation.

[16]  J Jankovic,et al.  Environmental study of firefighters. , 1991, The Annals of occupational hygiene.

[17]  J. Stoker,et al.  The Department of Health and Human Services. , 1999, Home healthcare nurse.

[18]  Jennifer Roberts,et al.  Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures , 2017, Journal of occupational and environmental hygiene.

[19]  Jacob L. Borgerson,et al.  Characterization of Firefighter Smoke Exposure , 2014 .

[20]  Pär Sparén,et al.  Occupation and cancer – follow-up of 15 million people in five Nordic countries , 2009, Acta oncologica.

[21]  Kathleen M Waters,et al.  Exposure–response relationships for select cancer and non-cancer health outcomes in a cohort of US firefighters from San Francisco, Chicago and Philadelphia (1950–2009) , 2015, Occupational and Environmental Medicine.

[22]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[23]  E. Dunlap,et al.  National Fire Protection Association , 2020, Motor Carrier Safety.

[24]  Denise L. Smith,et al.  Extreme sacrifice: sudden cardiac death in the US Fire Service , 2013, Extreme Physiology & Medicine.

[25]  이수정 해외산업간호정보 - 미국 산업안전보건연구원(National Institute for Occupational Safety and Health) 소개 , 2009 .

[26]  American Conference Of Governmental Industrial Hygienists 1998 Ventilation A O , 2019 .

[27]  Bruce P. Bernard,et al.  Biomonitoring of chemical exposure among New York City firefighters responding to the World Trade Center fire and collapse. , 2003, Environmental health perspectives.

[28]  D. Dockery,et al.  Health Effects of Fine Particulate Air Pollution: Lines that Connect , 2006, Journal of the Air & Waste Management Association.

[29]  R. Cress,et al.  Risk of cancer among firefighters in California, 1988-2007. , 2015, American journal of industrial medicine.

[30]  Douglas E. Evans,et al.  Ultrafine and respirable particle exposure during vehicle fire suppression. , 2015, Environmental science. Processes & impacts.

[31]  G. Horn,et al.  Evaluation of dermal exposure to polycyclic aromatic hydrocarbons in fire fighters , 2013 .

[32]  Kevin H. Dunn,et al.  Aerosol Monitoring during Carbon Nanofiber Production: Mobile Direct-Reading Sampling , 2010, The Annals of occupational hygiene.

[33]  W. MacNee,et al.  Particulate air pollution and acute health effects , 1995, The Lancet.

[34]  C D Crutchfield,et al.  Characterization of firefighter exposures during fire overhaul. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[35]  W. MacNee,et al.  Ultrafine (nanometre) particle mediated lung injury , 1998 .