Combining contaminant event diagnosis with data validation/reconstruction: Application to smart buildings

In this work, a combined sensor data validation/reconstruction and contaminant event diagnosis approach is proposed for Smart Building systems, implemented as a two-stage approach. In the first stage, sensor communication faults are detected and missing data is estimated, in order to provide a reliable dataset to perform contaminant event diagnosis in the second stage. For the first stage, the sensor validation and reconstruction technique is based on the combined use of spatial and time series models. On the one hand, spatial models take advantage of the physical relation between different variables in the system, whilst on the other hand, time series models take advantage of the temporal redundancy of the measured variables, using Holt-Winters time series models. For the second stage, contaminant event diagnosis is based on contaminant detection and isolation estimator schemes, using adaptive thresholds by assuming certain bounds on the measurement noise and the model uncertainty. In order to apply these diagnosis schemes, state-space models have been considered in order to model the contaminant dispersion over the indoor building environment, where the contaminant event is modelled as a fault in the process which needs to be detected and isolated. Finally, the proposed approach is successfully demonstrated for the Holmes House smart building scenario.

[1]  Qingyan Chen,et al.  Using CFD Capabilities of CONTAM 3.0 for Simulating Airflow and Contaminant Transport in and around Buildings , 2010 .

[2]  A J Gadgil,et al.  Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools. , 2003, Indoor air.

[3]  Marios M. Polycarpou,et al.  Contaminant event monitoring in multi-zone buildings using the state-space method , 2014 .

[4]  Peter Steen Mikkelsen,et al.  Quality control of rain data used for urban runoff systems , 1997 .

[5]  Marios M. Polycarpou,et al.  Design and analysis of a fault isolation scheme for a class of uncertain nonlinear systems , 2008, Annu. Rev. Control..

[6]  Derek Clements-Croome,et al.  Past, present and future mathematical models for buildings , 2009 .

[7]  Marios M. Polycarpou,et al.  A Matlab-CONTAM Toolbox for Contaminant Event Monitoring in Intelligent Buildings , 2013, AIAI.

[8]  D Burnell Auto-validation of district meter data , 2003 .

[9]  Marios M. Polycarpou,et al.  Contaminant Event Monitoring in Intelligent Buildings Using a Multi-Zone Formulation , 2012 .

[10]  Peter R. Winters,et al.  Forecasting Sales by Exponentially Weighted Moving Averages , 1960 .

[11]  Steven C. Wheelwright,et al.  Forecasting methods and applications. , 1979 .

[12]  Zhiqiang John Zhai,et al.  Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling , 2009 .

[13]  J.E. Braun,et al.  Intelligent Building Systems - Past, Present, and Future , 2007, 2007 American Control Conference.

[14]  Vicenç Puig,et al.  Validation and reconstruction of flow meter data in the Barcelona water distribution network , 2010 .

[15]  X Liu,et al.  Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals. , 2007, Indoor air.

[16]  K M Tsang Sensor data validation using gray models. , 2003, ISA transactions.