3D curvature of muscle fascicles in triceps surae.

Muscle fascicles curve along their length, with the curvatures occurring around regions of high intramuscular pressure, and are necessary for mechanical stability. Fascicles are typically considered to lie in fascicle planes that are the planes visualized during dissection or two-dimensional (2D) ultrasound scans. However, it has previously been predicted that fascicles must curve in three-dimensional (3D) and thus the fascicle planes may actually exist as 3D sheets. 3D fascicle curvatures have not been explored in human musculature. Furthermore, if the fascicles do not lie in 2D planes, then this has implications for architectural measures that are derived from 2D ultrasound scans. The purpose of this study was to quantify the 3D curvatures of the muscle fascicles and fascicle sheets within the triceps surae muscles and to test whether these curvatures varied among different contraction levels, muscle length, and regions within the muscle. Six male subjects were tested for three torque levels (0, 30, and 60% maximal voluntary contraction) and four ankle angles (-15, 0, 15, and 30° plantar flexion), and fascicles were imaged using 3D ultrasound techniques. The fascicle curvatures significantly increased at higher ankle torques and shorter muscle lengths. The fascicle sheet curvatures were of similar magnitude to the fascicle curvatures but did not vary between contractions. Fascicle curvatures were regionalized within each muscle with the curvature facing the deeper aponeuroses, and this indicates a greater intramuscular pressure in the deeper layers of muscles. Muscle architectural measures may be in error when using 2D images for complex geometries such as the soleus.

[1]  J L Van Leeuwen,et al.  Modelling mechanically stable muscle architectures. , 1992, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[2]  P. Cerretelli,et al.  In vivo human gastrocnemius architecture with changing joint angle at rest and during graded isometric contraction. , 1996, The Journal of physiology.

[3]  Thomas Neuberger,et al.  The Arrangement of Fascicles in Whole Muscle , 2012, Anatomical record.

[4]  M. Narici,et al.  Behavior of human muscle fascicles during shortening and lengthening contractions in vivo. , 2003, Journal of applied physiology.

[5]  T. Fukunaga,et al.  Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit. , 2002, Journal of biomechanics.

[6]  James M Wakeling,et al.  In-vivo determination of 3D muscle architecture of human muscle using free hand ultrasound. , 2011, Journal of biomechanics.

[7]  C. Maganaris,et al.  In vivo measurements of the triceps surae complex architecture in man: implications for muscle function , 1998, The Journal of physiology.

[8]  T. Fukunaga,et al.  Architectural and functional features of human triceps surae muscles during contraction. , 1998, Journal of applied physiology.

[9]  Heiko Stark,et al.  A novel method of studying fascicle architecture in relaxed and contracted muscles. , 2010, Journal of biomechanics.

[10]  E. Fiume,et al.  Documentation and three‐dimensional modelling of human soleus muscle architecture , 2003, Clinical anatomy.

[11]  James M Wakeling,et al.  Computational methods for quantifying in vivo muscle fascicle curvature from ultrasound images. , 2011, Journal of biomechanics.

[12]  Andrew A Biewener,et al.  Functional diversification within and between muscle synergists during locomotion , 2008, Biology Letters.

[13]  Susumu Mori,et al.  Fiber tracking: principles and strategies – a technical review , 2002, NMR in biomedicine.

[14]  James M Wakeling,et al.  The effect of external compression on the mechanics of muscle contraction. , 2013, Journal of applied biomechanics.

[15]  R. McN. Alexander,et al.  The orientation of muscle fibres in the myomeres of fishes , 1969, Journal of the Marine Biological Association of the United Kingdom.

[16]  Yasuo Kawakami,et al.  In vivo determination of fascicle curvature in contracting human skeletal muscles. , 2002, Journal of applied physiology.

[17]  T. Fukunaga,et al.  Muscle-fiber pennation angles are greater in hypertrophied than in normal muscles. , 1993, Journal of applied physiology.

[18]  A J Sargeant,et al.  Differences in human antagonistic ankle dorsiflexor coactivation between legs; can they explain the moment deficit in the weaker plantarflexor leg? , 1998, Experimental physiology.

[19]  C W Spoor,et al.  A two dimensional model for the prediction of muscle shape and intramuscular pressure. , 1996, European journal of morphology.

[20]  J. L. van Leeuwen,et al.  A two dimensional model for the prediction of muscle shape and intramuscular pressure. , 1996 .

[21]  A simple anatomical model of muscle, and the effects of internal pressure. , 1979, Bulletin of mathematical biology.

[22]  E. Otten Concepts and Models of Functional Architecture in Skeletal Muscle , 1988, Exercise and sport sciences reviews.

[23]  Lawrence C. Rome,et al.  Why animals have different muscle fibre types , 1988, Nature.

[24]  Anna-Maria Liphardt,et al.  Task-specific recruitment of motor units for vibration damping. , 2006, Journal of biomechanics.

[25]  Ghassan Hamarneh,et al.  3D fascicle orientations in triceps surae. , 2013, Journal of applied physiology.

[26]  Ghassan Hamarneh,et al.  Automated Tracking of Muscle Fascicle Orientation in B-mode Ultrasound Images , 2022 .

[27]  Zhaohua Ding,et al.  Quantitative assessment of DTI‐based muscle fiber tracking and optimal tracking parameters , 2009, Magnetic resonance in medicine.

[28]  Peter A Huijing,et al.  Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry , 2009, Muscle & nerve.

[29]  Tzyy-Yuang Shiang,et al.  Noninvasive analysis of fascicle curvature and mechanical hardness in calf muscle during contraction and relaxation. , 2009, Manual therapy.

[30]  Hangyi Jiang,et al.  DtiStudio: Resource program for diffusion tensor computation and fiber bundle tracking , 2006, Comput. Methods Programs Biomed..

[31]  P. Cova,et al.  Effect of unintentionally introduced oxygen on the electron–cyclotron resonance chemical-vapor deposition of SiNX films , 2002 .

[32]  G. Lichtwark,et al.  Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running. , 2007, Journal of biomechanics.

[33]  C. Gans,et al.  The functional significance of muscle architecture--a theoretical analysis. , 1965, Ergebnisse der Anatomie und Entwicklungsgeschichte.

[34]  Ian David Loram,et al.  Use of ultrasound to make noninvasive in vivo measurement of continuous changes in human muscle contractile length. , 2006, Journal of applied physiology.

[35]  O. Sejersted,et al.  Intramuscular fluid pressure during isometric contraction of human skeletal muscle. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.