Reproduction of continuous flow left ventricular assist device experimental data by means of a hybrid cardiovascular model with baroreflex control.

Long-term mechanical circulatory assistance opened new problems in ventricular assist device-patient interaction, especially in relation to autonomic controls. Modeling studies, based on adequate models, could be a feasible approach of investigation. The aim of this work is the exploitation of a hybrid (hydronumerical) cardiovascular simulator to reproduce and analyze in vivo experimental data acquired during a continuous flow left ventricular assistance. The hybrid cardiovascular simulator embeds three submodels: a computational cardiovascular submodel, a computational baroreflex submodel, and a hydronumerical interface submodel. The last one comprises two impedance transformers playing the role of physical interfaces able to provide a hydraulic connection with specific cardiovascular sites (in this article, the left atrium and the ascending/descending aorta). The impedance transformers are used to connect a continuous flow pump for partial left ventricular support (Synergy Micropump, CircuLite, Inc., Saddlebrooke, NJ, USA) to the hybrid cardiovascular simulator. Data collected from five animals in physiological, pathological, and assisted conditions were reproduced using the hybrid cardiovascular simulator. All parameters useful to characterize and tune the hybrid cardiovascular simulator to a specific hemodynamic condition were extracted from experimental data. Results show that the simulator is able to reproduce animal-specific hemodynamic status both in physiological and pathological conditions, to reproduce cardiovascular left ventricular assist device (LVAD) interaction and the progressive unloading of the left ventricle for different pump speeds, and to investigate the effects of the LVAD on baroreflex activity. Results in chronic heart failure conditions show that an increment of LVAD speed from 20 000 to 22 000 rpm provokes a decrement of left ventricular flow of 35% (from 2 to 1.3 L/min). Thanks to its flexibility and modular structure, the simulator is a platform potentially useful to test different assist devices, thus providing clinicians additional information about LVAD therapy strategy.

[1]  Y. Saijo,et al.  Analysis of baroreflex sensitivity during undulation pump ventricular assist device support. , 2009, Artificial organs.

[2]  Filip Rega,et al.  Clinical benefits of partial circulatory support in New York Heart Association Class IIIB and Early Class IV patients. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[3]  Maciej Kozarski,et al.  A modular computational circulatory model applicable to VAD testing and training , 2012, Journal of Artificial Organs.

[4]  H. Matsuda,et al.  Analysis of sympathetic nerve activity in end-stage cardiomyopathy patients receiving left ventricular support. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  A. Diedrich,et al.  Patients With Continuous-Flow Left Ventricular Assist Devices Provide Insight in Human Baroreflex Physiology , 2012, Hypertension.

[6]  M Ursino,et al.  The role of pressure pulsatility in the carotid baroreflex control: A computer simulation study , 1996, Comput. Biol. Medicine.

[7]  Peter Hunold,et al.  Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation. , 2005, AJR. American journal of roentgenology.

[8]  Lino Guzzella,et al.  A Novel Interface for Hybrid Mock Circulations to Evaluate Ventricular Assist Devices , 2013, IEEE Transactions on Biomedical Engineering.

[9]  M Arabia,et al.  Hybrid test bench for evaluation of any device related to mechanical cardiac assistance. , 2005, The International journal of artificial organs.

[10]  J. F. Antaki,et al.  Elastance-Based Control of a Mock Circulatory System , 2001, Annals of Biomedical Engineering.

[11]  Maciej Kozarski,et al.  Hybrid model analysis of intra-aortic balloon pump performance as a function of ventricular and circulatory parameters. , 2011, Artificial organs.

[12]  佐川 喜一,et al.  Cardiac contraction and the pressure-volume relationship , 1988 .

[13]  Maciej Kozarski,et al.  Effects of intra-aortic balloon pump timing on baroreflex activities in a closed-loop cardiovascular hybrid model. , 2013, Artificial organs.

[14]  R. Mark,et al.  Computational modeling of cardiovascular response to orthostatic stress. , 2002, Journal of applied physiology.

[15]  Gorczynska Krystyna,et al.  A Hybrid (Hydro-numerical) Cardiovascular Model: Application to Investigate Continuous-flow Pump Assistance Effect , 2012 .

[16]  B. Griffith,et al.  Partial left ventricular support implanted through minimal access surgery as a bridge to cardiac transplant. , 2009, The Journal of thoracic and cardiovascular surgery.

[17]  J. Pepper,et al.  A mock circulatory system with physiological distribution of terminal resistance and compliance: application for testing the intra-aortic balloon pump. , 2012, Artificial organs.

[18]  T. Korakianitis,et al.  Numerical simulation of cardiovascular dynamics with different types of VAD assistance. , 2007, Journal of biomechanics.

[19]  R H Cox,et al.  Baroreceptor Reflex Control of Arterial Hemodynamics in the Dog , 1975, Circulation research.

[20]  J D Thomas,et al.  Numeric modeling of the cardiovascular system with a left ventricular assist device. , 1999, ASAIO journal.

[21]  M. Ursino,et al.  Interaction between carotid baroregulation and the pulsating heart : a mathematical model , 1998 .

[22]  A. Shoukas,et al.  The Effect of the Carotid Sinus Baroreceptor Reflex on Blood Flow and Volume Redistribution in the Total Systemic Vascular Bed of the Dog , 1981, Circulation research.

[23]  A A Shoukas,et al.  Epinephrine and the Carotid Sinus Baroreceptor Reflex: Influence on Capacitive and Resistive Properties of the Total Systemic Vascular Bed of the Dog , 1980, Circulation research.

[24]  Marcel C M Rutten,et al.  In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous. , 2011, Artificial organs.

[25]  Maciej Kozarski,et al.  A new hybrid electro-numerical model of the left ventricle , 2008, Comput. Biol. Medicine.

[26]  D L Eckberg,et al.  Autonomic pathophysiology in heart failure: carotid baroreceptor-cardiac reflexes. , 1990, The American journal of physiology.

[27]  M. Daly,et al.  Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus‐aortic arch regions of the dog , 1971, The Journal of physiology.

[28]  J.R. Boston,et al.  Feedback Control of an LVAD Supporting a Failing Cardiovascular System Regulated by the Baroreflex , 2006, Proceedings of the 45th IEEE Conference on Decision and Control.

[29]  Ulrich Steinseifer,et al.  A compact mock circulation loop for the in vitro testing of cardiovascular devices. , 2010, Artificial organs.