Adaptive power regulation and data delivery for multi-module implants

Emerging applications for implantable devices are requiring multi-unit systems with intrabody transmission of power and data through wireline interfaces. This paper proposes a novel method for power delivery within such a configuration that makes use of closed loop dynamic regulation. This is implemented for an implantable application requiring a single master and multiple identical slave devices utilising a parallel-connected 4-wire interface. The power regulation is achieved within the master unit through closed loop monitoring of the current consumption to the wired link. Simultaneous power transfer and full-duplex data communication is achieved by superimposing the power carrier and downlink data over two wires and uplink data over a second pair of wires. Measured results using a fully isolated (AC coupled) 4-wire lead, demonstrate this implementation can transmit up to 120 mW of power at 6 V (at the slave device, after eliminating any losses). The master device has a maximum efficiency of 80 % including a dominant dynamic power loss. A 6 V constant supply at the slave device is recovered 1.5 ms after a step of 22 mA.

[1]  Torsten Lehmann,et al.  Towards a chip scale neurostimulator: System architecture of a current-driven 98 channel neurostimulator via a two-wire interface , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  Torsten Lehmann,et al.  Low-power circuit structures for chip-scale stimulating implants , 2012, 2012 IEEE Asia Pacific Conference on Circuits and Systems.

[3]  Timothy G. Constandinou,et al.  Four-Wire Interface ASIC for a Multi-Implant Link , 2017, IEEE Transactions on Circuits and Systems I: Regular Papers.

[4]  B. Smith,et al.  Development of an implantable networked neuroprosthesis , 2005, Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005..

[5]  K.P. Koch,et al.  Implantable biomedical microsystems for neural prostheses , 2005, IEEE Engineering in Medicine and Biology Magazine.

[6]  Timothy G. Constandinou,et al.  An optrode with built-in self-diagnostic and fracture sensor for cortical brain stimulation , 2016, 2016 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[7]  Timothy G. Constandinou,et al.  A 4-wire interface SoC for shared multi-implant power transfer and full-duplex communication , 2017, 2017 IEEE 8th Latin American Symposium on Circuits & Systems (LASCAS).

[8]  Shun Bai,et al.  A Complete 256-Electrode Retinal Prosthesis Chip , 2014, IEEE Journal of Solid-State Circuits.

[9]  Timothy G. Constandinou,et al.  A CMOS-based neural implantable optrode for optogenetic stimulation and electrical recording , 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS).