Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison

This paper aims to identify the minimum requirements for an accurate model of the diffusion MR signal in white matter of the brain. We construct a taxonomy of multi-compartment models of white matter from combinations of simple models for the intra- and the extra-axonal spaces. We devise a new diffusion MRI protocol that provides measurements with a wide range of imaging parameters for diffusion sensitization both parallel and perpendicular to white matter fibres. We use the protocol to acquire data from two fixed rat brains, which allows us to fit, study and compare the different models. The study examines a total of 47 analytic models, including several well-used models from the literature, which we place within the taxonomy. The results show that models that incorporate intra-axonal restriction, such as ball and stick or CHARMED, generally explain the data better than those that do not, such as the DT or the biexponential models. However, three-compartment models which account for restriction parallel to the axons and incorporate pore size explain the measurements most accurately. The best fit comes from combining a full diffusion tensor (DT) model of the extra-axonal space with a cylindrical intra-axonal component of single radius and a third spherical compartment of non-zero radius. We also measure the stability of the non-zero radius intra-axonal models and find that single radius intra-axonal models are more stable than gamma distributed radii models with similar fitting performance.

[1]  A. Scheibel,et al.  Fiber composition of the human corpus callosum , 1992, Brain Research.

[2]  P. Basser,et al.  New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter , 2004, Magnetic resonance in medicine.

[3]  D. Yablonskiy,et al.  Biophysical mechanisms of phase contrast in gradient echo MRI , 2009, Proceedings of the National Academy of Sciences.

[4]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[5]  G. Schwarz Estimating the Dimension of a Model , 1978 .

[6]  P. V. van Zijl,et al.  Evaluation of restricted diffusion in cylinders. Phosphocreatine in rabbit leg muscle. , 1994, Journal of magnetic resonance. Series B.

[7]  W. Baaré,et al.  An ex vivo imaging pipeline for producing high‐quality and high‐resolution diffusion‐weighted imaging datasets , 2011, Human brain mapping.

[8]  P. Basser,et al.  MR diffusion tensor spectroscopy and imaging. , 1994, Biophysical journal.

[9]  D. Alexander A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure features , 2008, Magnetic resonance in medicine.

[10]  Carl-Fredrik Westin,et al.  Geometrically constrained two-tensor model for crossing tracts in DWI. , 2006, Magnetic resonance imaging.

[11]  M. Mallar Chakravarty,et al.  Neurite density from magnetic resonance diffusion measurements at ultrahigh field: Comparison with light microscopy and electron microscopy , 2010, NeuroImage.

[12]  C. H. Neuman Spin echo of spins diffusing in a bounded medium , 1974 .

[13]  Timothy Edward John Behrens,et al.  High resolution diffusion-weighted imaging in fixed human brain using diffusion-weighted steady state free precession , 2009, NeuroImage.

[14]  Janez Stepišnik,et al.  Time-dependent self-diffusion by NMR spin-echo , 1993 .

[15]  Derek K. Jones,et al.  “Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data , 2004, Magnetic resonance in medicine.

[16]  Eleftheria Panagiotaki Geometric models of brain white matter for microstructure imaging with diffusion MRI , 2011 .

[17]  J. S. Murday,et al.  Self‐Diffusion Coefficient of Liquid Lithium , 1968 .

[18]  N. Makris,et al.  High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity , 2002, Magnetic resonance in medicine.

[19]  Daniel C. Alexander,et al.  Probabilistic Monte Carlo Based Mapping of Cerebral Connections Utilising Whole-Brain Crossing Fibre Information , 2003, IPMI.

[20]  Paul T. Callaghan,et al.  Frequency-Domain Analysis of Spin Motion Using Modulated-Gradient NMR , 1995 .

[21]  Jürgen Finsterbusch,et al.  Compartment size estimation with double wave vector diffusion‐weighted imaging , 2008, Magnetic resonance in medicine.

[22]  Daniel C Alexander,et al.  Optimizing gradient waveforms for microstructure sensitivity in diffusion-weighted MR. , 2010, Journal of magnetic resonance.

[23]  Leif Østergaard,et al.  Modeling dendrite density from magnetic resonance diffusion measurements , 2007, NeuroImage.

[24]  Gareth J. Barker,et al.  Optimal imaging parameters for fiber-orientation estimation in diffusion MRI , 2005, NeuroImage.

[25]  William S. Price,et al.  Pulsed-field gradient nuclear magnetic resonance as a tool for studying translational diffusion, part 1: basic theory , 1997 .

[26]  Peter J Basser,et al.  Measuring small compartmental dimensions with low-q angular double-PGSE NMR: The effect of experimental parameters on signal decay. , 2009, Journal of magnetic resonance.

[27]  Daniel C. Alexander,et al.  MicroTrack: An Algorithm for Concurrent Projectome and Microstructure Estimation , 2010, MICCAI.

[28]  Daniel C. Alexander,et al.  Active Imaging with Dual Spin-Echo Diffusion MRI , 2009, IPMI.

[29]  Mark F. Lythgoe,et al.  Two-Compartment Models of the Diffusion MR Signal in Brain White Matter , 2009, MICCAI.

[30]  P. Basser,et al.  Axcaliber: A method for measuring axon diameter distribution from diffusion MRI , 2008, Magnetic resonance in medicine.

[31]  Yaniv Assaf,et al.  Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain , 2005, NeuroImage.

[32]  Hui Zhang,et al.  Axon diameter mapping in the presence of orientation dispersion with diffusion MRI , 2011, NeuroImage.

[33]  Daniel C. Alexander,et al.  Camino: Open-Source Diffusion-MRI Reconstruction and Processing , 2006 .

[34]  D. Le Bihan,et al.  Water diffusion compartmentation and anisotropy at high b values in the human brain , 2000, Magnetic resonance in medicine.

[35]  A. Szafer,et al.  An analytical model of restricted diffusion in bovine optic nerve , 1997, Magnetic resonance in medicine.

[36]  Timothy Edward John Behrens,et al.  Characterization and propagation of uncertainty in diffusion‐weighted MR imaging , 2003, Magnetic resonance in medicine.

[37]  P. Basser,et al.  In vivo measurement of axon diameter distribution in the corpus callosum of rat brain. , 2009, Brain : a journal of neurology.

[38]  Daniel Nilsson,et al.  Alteration of diffusion tensor parameters in postmortem brain. , 2009, Magnetic resonance imaging.

[39]  Stephen J Blackband,et al.  Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue , 2009, Magnetic resonance in medicine.

[40]  D. Norris,et al.  Biexponential diffusion attenuation in various states of brain tissue: Implications for diffusion‐weighted imaging , 1996, Magnetic resonance in medicine.

[41]  Hans Hagen,et al.  Visualization and Processing of Tensor Fields , 2014 .

[42]  Thomas R. Knösche,et al.  Parametric spherical deconvolution: Inferring anatomical connectivity using diffusion MR imaging , 2007, NeuroImage.

[43]  Tim B. Dyrby,et al.  Axon Diameter Mapping in Crossing Fibers with Diffusion MRI , 2011, MICCAI.

[44]  Derek K. Jones,et al.  Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review , 2002 .

[45]  Tim B. Dyrby,et al.  Orientationally invariant indices of axon diameter and density from diffusion MRI , 2010, NeuroImage.

[46]  J. Gore,et al.  Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain , 2003, Magnetic resonance in medicine.

[47]  William S. Price,et al.  Pulsed-Field Gradient Nuclear Magnetic Resonance as a Tool for Studying Translational Diffusion. Part 1. Basic Theory , 1997 .

[48]  D. C. Douglass,et al.  Diffusion in Paraffin Hydrocarbons , 1958 .

[49]  Mitra,et al.  Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement. , 1995, Physical review. B, Condensed matter.

[50]  Daniel C. Alexander,et al.  Modelling, Fitting and Sampling in Diffusion MRI , 2009 .