Simulation Calculation of Spiral Condenser about Refrigerant System
暂无分享,去创建一个
This paper establish a simulation program about the spiral condenser based on theoretical behavior of thermal parameters used R134a as refrigerant, analysis the influence of heat transfer area on refrigerant performance, and calculate best length of condenser heat transfer tube. The results show that the tread of coefficient of performance(COP) and cooling capacity of the system is similar along with the heat transfer tube length, and the research for the optimization design about spiral condenser heat exchanger provides the theoretical support.
[1] M. Kedzierski,et al. Horizontal Convective Condensation of Alternative Refrigerants Within a Micro-Fin Tube , 1997 .
[2] G. N. Kruzhilin,et al. Heat transfer and hydraulic resistance during condensation of steam in a horizontal tube and in a bundle of tubes , 1967 .
[3] Tang Dongmei,et al. Design and Realization of the Digital Campus of Xi'an University of Architecture and Technology , 2010 .
[4] S. Koyama,et al. Condensation Heat Transfer of Pure Refrigerants in Microfin Tubes , 1998 .