Optimization of Signal-to-Noise Ratio for Multilayer Pzt Transducers

In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedance near the resonance frequency. This results in poor signal-to-noise ratio (SNR) of the array elements. It has previously been demonstrated that transducers made from multilayer PZT ceramics have lower electrical impedance and greater SNR than comparable single layer elements. A simplified circuit model has been developed to optimize the SNR for multilayer ceramic (MLC) transducers. In this model, an electronic transmitter excites the array element and in the receive mode, the element drives a coaxial cable load terminated by a high impedance preamplifier. The transducer impedance is Zt/N2, where N is the number of piezoelectric layers. Maximum transmit signal is obtained when N = Ntx such that the transducer impedance, Zt/Ntx 2, is matched to the source impedance. Maximum receive signal is obtained when N = Nrx such that the transducer impedance, Zt/Nrx 2, is matched to the coaxial cable reactance. For maximum pulse-echo signal, the transducer should be designed with N = , the geometric mean of Ntx and Nrx. Using this optimization technique, a 1.5-D array was designed with 3 layers for maximum pulse-echo SNR. Results of simulations from the simplified circuit analysis were consistent with those of the KLM model. The 3 layer array was fabricated as well as a single layer control array. The measured transmit signal and receive signal agreed with the simulation results.

[1]  J. W. Young Optimization of acoustic receiver noise performance , 1977 .

[2]  R. Krimholtz,et al.  Equivalent Circuits for Transducers Having Arbitrary Even- Or Odd-Symmetry Piezoelectric Excitation , 1971, IEEE Transactions on Sonics and Ultrasonics.

[3]  Robert J. Bobber,et al.  Underwater Electroacoustic Measurements , 1990 .

[4]  Peter A. Lewin,et al.  Enhanced bandwidth ultrasound transducers with multiple piezoelectric polymer layers , 1992, SPIE Optics + Photonics.

[5]  Najib N. Abboud,et al.  Electromechanical modeling using explicit time-domain finite elements , 1993 .

[6]  In Vivo Imaging Using a Copolymer Phased Array , 1992, Ultrasonic imaging.

[7]  R. E. Davidsen,et al.  Two-Dimensional Random Arrays for Real Time Volumetric Imaging , 1994 .

[8]  F. Foster,et al.  Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays. , 1992, Ultrasonic imaging.

[9]  F. Stuart Foster,et al.  Simulation of B-Scan Images from Two-Dimensional Transducer Arrays: Part Ii - Comparisons between Linear and Two-Dimensional Phased Arrays , 1992 .

[10]  Olaf T. von Ramm,et al.  Real-time volumetric ultrasound imaging system , 1990, Medical Imaging.

[11]  S.W. Smith,et al.  Multilayer piezoelectric ceramics for two-dimensional array transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  S.W. Smith,et al.  Experimental results with a real-time adaptive ultrasonic imaging system for viewing through distorting media , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Thomas R. Shrout,et al.  Piezoelectric properties of internally electroded PZT multilayers , 1980 .

[15]  F L Thurstone,et al.  Cardiac Imaging Using a Phased Array Ultrasound System: I. System Design , 1976, Circulation.

[16]  Mamoru Izumi,et al.  A Low-Impedance Ultrasonic Probe Using a Multilayer Piezoelectric Ceramic , 1989 .