Functionalization of the Polymeric Surface with Bioceramic Nanoparticles via a Novel, Nonthermal Dip Coating Method.

The only nonthermal method of depositing a bioceramic-based coating on polymeric substrates is by incubation in liquid, e.g., simulated body fluid to form an apatite-like layer. The drawbacks of this method include the long processing time, the production of low scratch resistant coating, and an end product that does not resemble the intended bioceramic composition. Techniques, such as plasma spraying and magnetron sputtering, involving high processing temperature are unsuitable for polymers, e.g., PMMA. Here, we introduce a nonthermal coating method to immobilize hydroxyapatite (HAp) and TiO2 nanoparticles on PMMA via a simple and fast dip coating method. Cavities that formed on the PMMA, induced by chloroform, appeared to trap the nanoparticles which accumulated to form layers of bioceramic coating only after 60 s. The resulting coating was hydrophilic and highly resistant to delamination. In the context of our research and to address the current clinical need, we demonstrate that the HAp-coated PMMA, which is intended to be used as a visual optic of a corneal prosthetic device, improves its bonding and biointegration with collagen, the main component of a corneal stroma. The HAp-coated PMMA resulted in better adhesion with the collagen than untreated PMMA in artificial tear fluid over 28 days. Human corneal stromal fibroblasts showed better attachment, viability, and proliferation rate on the HAp-coated PMMA than on untreated PMMA. This coating method is an innovative solution to immobilize various bioceramic nanoparticles on polymers and may be used in other biomedical implants.

[1]  J. Childress,et al.  Ethical criteria for procuring and distributing organs for transplantation. , 1989, Journal of health politics, policy and law.

[2]  Dennis E. Cortés,et al.  High-Resolution Spectral Domain Anterior Segment Optical Coherence Tomography in Type 1 Boston Keratoprosthesis , 2013, Cornea.

[3]  A. Durán,et al.  Bioactive coatings prepared by sol-gel on stainless steel 316L , 2004 .

[4]  Hau Chung Man,et al.  Characterization and corrosion behavior of hydroxyapatite coatings on Ti6Al4V fabricated by electrophoretic deposition , 2009 .

[5]  Chunjie Wu,et al.  In Situ Gelling Gelrite/Alginate Formulations as Vehicles for Ophthalmic Drug Delivery , 2010, AAPS PharmSciTech.

[6]  Xavier Trepat,et al.  Rigidity sensing and adaptation through regulation of integrin types , 2014, Nature materials.

[7]  C. Watson,et al.  Organ transplantation: historical perspective and current practice. , 2012, British journal of anaesthesia.

[8]  T. Nieh,et al.  Processing and characterization of hydroxyapatite coatings on titanium produced by magnetron sputtering , 2001 .

[9]  J. Forrester,et al.  Regenerative approaches as alternatives to donor allografting for restoration of corneal function. , 2012, The ocular surface.

[10]  M. Durand,et al.  Endophthalmitis after keratoprosthesis: incidence, bacterial causes, and risk factors. , 2001, Archives of ophthalmology.

[11]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[12]  C. Ding,et al.  Bond strength of plasma-sprayed hydroxyapatite/Ti composite coatings. , 2000, Biomaterials.

[13]  Matthew C. Dixon,et al.  Quartz crystal microbalance with dissipation monitoring: enabling real-time characterization of biological materials and their interactions. , 2008, Journal of biomolecular techniques : JBT.

[14]  M. Fathi,et al.  In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[15]  Y. Mascarenhas,et al.  XRD, AFM, IR and TGA Study of Nanostructured Hydroxyapatite , 2012 .

[16]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[17]  A. Durán,et al.  Protective hybrid sol-gel coatings containing bioactive particles on surgical grade stainless steel: Surface characterization , 2007 .

[18]  A. Rakowska,et al.  Electrophoretic coating of hydroxyapatite on titanium implants , 2001 .

[19]  J. Mora,et al.  Seoul type keratoprosthesis: Preliminary results of the first 7 human cases , 2002 .

[20]  K. J. Jeong,et al.  Titanium Coating of the Boston Keratoprosthesis , 2016, Translational vision science & technology.

[21]  J M Legeais,et al.  A second generation of artificial cornea (Biokpro II). , 1998, Biomaterials.

[22]  D. Sarma,et al.  Size-Selected Zinc Sulfide Nanocrystallites: Synthesis, Structure, and Optical Studies , 2000 .

[23]  S. Wooding,et al.  The answer is 17 years, what is the question: understanding time lags in translational research , 2011, Journal of the Royal Society of Medicine.

[24]  B. Liu,et al.  Fabrication and biocompatibility investigation of TiO(2) films on the polymer substrates obtained via a novel and versatile route. , 2010, Colloids and surfaces. B, Biointerfaces.

[25]  J. Seitz,et al.  Polymer–bioceramic composite coatings on magnesium for biomaterial applications , 2013 .

[26]  J. Tanaka,et al.  Composition and structure of apatite formed on organic polymer in simulated body fluid with a high content of carbonate ion , 2000, Journal of materials science. Materials in medicine.

[27]  Rejean Munger,et al.  A simple, cross-linked collagen tissue substitute for corneal implantation. , 2006, Investigative ophthalmology & visual science.

[28]  G. Sauerbrey,et al.  The use of quarts oscillators for weighing thin layers and for microweighing , 1959 .

[29]  J. Goddard,et al.  Polymer surface modification for the attachment of bioactive compounds , 2007 .

[30]  Haeshin Lee,et al.  Mussel‐Inspired Polydopamine Coating as a Universal Route to Hydroxyapatite Crystallization , 2010 .

[31]  Larry L. Hench,et al.  Bonding mechanisms at the interface of ceramic prosthetic materials , 1971 .

[32]  J. Mehta,et al.  Surface Modification of PMMA to Improve Adhesion to Corneal Substitutes in a Synthetic Core-Skirt Keratoprosthesis. , 2015, ACS applied materials & interfaces.

[33]  M. K. Herliansyah,et al.  Adhesion failure behavior of sputtered calcium phosphate thin film coatings evaluated using microscratch testing. , 2010, Journal of the mechanical behavior of biomedical materials.