A study to establish international diagnostic reference levels for paediatric computed tomography.

The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDIw, CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75th percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided.

[1]  Sheila Weinmann,et al.  The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. , 2013, JAMA pediatrics.

[2]  Virginia Tsapaki,et al.  Impact of the International Atomic Energy Agency (IAEA) actions on radiation protection of patients in many countries. , 2011, Radiation protection dosimetry.

[3]  B. Wall,et al.  Reference Doses for Paediatric Computed Tomography , 2000 .

[4]  R. Zeman,et al.  Diagnostic reference levels from the ACR CT Accreditation Program. , 2011, Journal of the American College of Radiology : JACR.

[5]  H. Järvinen,et al.  Patient doses in paediatric CT: feasibility of setting diagnostic reference levels. , 2011, Radiation protection dosimetry.

[6]  J Vassileva,et al.  Patient grouping for dose surveys and establishment of diagnostic reference levels in paediatric computed tomography. , 2015, Radiation protection dosimetry.

[7]  K Ohno,et al.  Paediatric CT examinations in 19 developing countries: frequency and radiation dose. , 2010, Radiation protection dosimetry.

[8]  D. Larson,et al.  Diagnostic reference ranges for pediatric abdominal CT. , 2013, Radiology.

[9]  W. Huda,et al.  X-ray beam filtration, dosimetry phantom size and CT patient dose conversion factors , 2010, Physics in medicine and biology.

[10]  P. Roch,et al.  French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004-2008 review. , 2013, Radiation protection dosimetry.

[11]  J. Mathews,et al.  Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians , 2013, BMJ.

[12]  Walter Huda,et al.  Radiation Risk to Children From Computed Tomography , 2007, Pediatrics.

[13]  Vesna Gershan,et al.  IAEA survey of pediatric CT practice in 40 countries in Asia, Europe, Latin America, and Africa: Part 1, frequency and appropriateness. , 2012, AJR. American journal of roentgenology.

[14]  Y. Tsushima,et al.  Diagnostic reference level of computed tomography (CT) in Japan. , 2012, Radiation protection dosimetry.

[15]  K. P. Kim,et al.  Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study , 2012, The Lancet.

[16]  Young Hoon Roh,et al.  The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy , 2015 .

[17]  B. Aubert,et al.  Niveaux d'exposition en tomodensitométrie multicoupes pédiatrique : résultats de l'enquête dosimétrique SFIPP/IRSN 2007-2008 , 2009 .

[18]  E. Georgiou,et al.  EFFECTIVE DOSE VARIATION IN PEDIATRIC COMPUTED TOMOGRAPHY: DOSE REFERENCE LEVELS IN GREECE , 2009, Health physics.

[19]  D. Brenner,et al.  Estimated risks of radiation-induced fatal cancer from pediatric CT. , 2001, AJR. American journal of roentgenology.

[20]  P. Visrutaratna,et al.  Survey of pediatric MDCT radiation dose from university hospitals in Thailand: a preliminary for national dose survey , 2012, Acta radiologica.

[21]  D McLean,et al.  Paediatric and adult computed tomography practice and patient dose in Australia. , 2006, Australasian radiology.

[22]  Jenia Vassileva,et al.  IAEA survey of paediatric computed tomography practice in 40 countries in Asia, Europe, Latin America and Africa: procedures and protocols , 2012, European Radiology.

[23]  F. Gudinchet,et al.  CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland , 2008, European Radiology.

[24]  P. Vaz,et al.  Assessment of paediatric CT exposure in a Portuguese hospital. , 2012, Radiation protection dosimetry.