Dynamic Temperature and Humidity Environmental Profiles: Impact for Future Emergency and Disaster Preparedness and Response

INTRODUCTION During disasters and complex emergencies, environmental conditions can adversely affect the performance of point-of-care (POC) testing. Knowledge of these conditions can help device developers and operators understand the significance of temperature and humidity limits necessary for use of POC devices. First responders will benefit from improved performance for on-site decision making. OBJECTIVE To create dynamic temperature and humidity profiles that can be used to assess the environmental robustness of POC devices, reagents, and other resources (eg, drugs), and thereby, to improve preparedness. METHODS Surface temperature and humidity data from the National Climatic Data Center (Asheville, North Carolina USA) was obtained, median hourly temperature and humidity were calculated, and then mathematically stretched profiles were created to include extreme highs and lows. Profiles were created for: (1) Banda Aceh, Indonesia at the time of the 2004 Tsunami; (2) New Orleans, Louisiana USA just before and after Hurricane Katrina made landfall in 2005; (3) Springfield, Massachusetts USA for an ambulance call during the month of January 2009; (4) Port-au-Prince, Haiti following the 2010 earthquake; (5) Sendai, Japan for the March 2011 earthquake and tsunami with comparison to the colder month of January 2011; (6) New York, New York USA after Hurricane Sandy made landfall in 2012; and (7) a 24-hour rescue from Hawaii USA to the Marshall Islands. Profiles were validated by randomly selecting 10 days and determining if (1) temperature and humidity points fell inside and (2) daily variations were encompassed. Mean kinetic temperatures (MKT) were also assessed for each profile. RESULTS Profiles accurately modeled conditions during emergency and disaster events and enclosed 100% of maximum and minimum temperature and humidity points. Daily variations also were represented well with 88.6% (62/70) of temperature readings and 71.1% (54/70) of relative humidity readings falling within diurnal patterns. Days not represented well primarily had continuously high humidity. Mean kinetic temperature was useful for severity ranking. CONCLUSIONS Simulating temperature and humidity conditions clearly reveals operational challenges encountered during disasters and emergencies. Understanding of environmental stresses and MKT leads to insights regarding operational robustness necessary for safe and accurate use of POC devices and reagents. Rescue personnel should understand these principles before performing POC testing in adverse environments.

[1]  S Colagiuri,et al.  Effect of Ambient Temperature and Humidity on Performance of Blood Glucose Meters , 1995, Diabetic medicine : a journal of the British Diabetic Association.

[2]  G. Kost,et al.  Thermal Stress and Point-of-Care Testing Performance: Suitability of Glucose Test Strips and Blood Gas Cartridges for Disaster Response , 2009, Disaster Medicine and Public Health Preparedness.

[3]  John H. Vy,et al.  Ensuring quality control of point-of-care technologies: Effects of dynamic temperature and humidity stresses on glucose quality control solutions , 2012 .

[4]  C Thibeault,et al.  Cabin air quality. Aerospace Medical Association. , 1997, Aviation, space, and environmental medicine.

[5]  Michael J Rust,et al.  A thermo-modulating container for transport and storage of glucose meters in a cold weather environment , 2012 .

[6]  M F Burritt,et al.  Evaluation of the i-STAT portable clinical analyzer for use in a helicopter. , 1996, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[7]  M. Burritt,et al.  Airborne and rescue point-of-care testing. , 1995, American journal of clinical pathology.

[8]  R. Carroll,et al.  Environmental temperature variations cause degradations in epinephrine concentration and biological activity. , 1994, The American journal of emergency medicine.

[9]  W. P. Oliveira,et al.  Storage Conditions for Stability Testing of Pharmaceuticals in Hot and Humid Regions , 2007, Drug development and industrial pharmacy.

[10]  John H. Vy,et al.  Preliminary evaluation of a point-of-care blood gas-electrolyte analyzer potentially robust in cold during emergencies and disasters: Evidence from evaluation of reagents in stress testing chambers , 2012 .

[11]  R. Vanholder,et al.  When the Earth Trembles in the Americas: The Experience of Haiti and Chile 2010 , 2010, Nephron Clinical Practice.

[12]  Scott M Smith,et al.  Stability of i-Stat EC6+ cartridges: effect of storage temperature on shelf life. , 2004, Clinical chemistry.

[13]  Jonathan J Shuster,et al.  Adverse impact of temperature and humidity on blood glucose monitoring reliability: a pilot study. , 2007, Diabetes technology & therapeutics.

[14]  John H. Vy,et al.  Effects of environmental conditions on point-of-care cardiac biomarker test performance during a simulated rescue: implications for emergency and disaster response. , 2013, American journal of disaster medicine.

[15]  H. Meislin,et al.  Thermal stability of prehospital medications. , 1989, Annals of emergency medicine.

[16]  Kelly R Klein,et al.  Mass medical evacuation: Hurricane Katrina and nursing experiences at the New Orleans airport. , 2007, Disaster management & response : DMR : an official publication of the Emergency Nurses Association.

[17]  Phillip J. Finley,et al.  Alteration in prehospital drug concentration after thermal exposure. , 2008, The American journal of emergency medicine.

[18]  William J Ferguson,et al.  Effects of Dynamic Temperature and Humidity Stresses on Point-of-Care Glucose Testing for Disaster Care , 2012, Disaster Medicine and Public Health Preparedness.

[19]  F. Di Serio,et al.  Laboratory testing during critical care transport: point-of-care testing in air ambulances , 2010, Clinical chemistry and laboratory medicine.

[20]  R. Bamberg,et al.  Effect of Adverse Storage Conditions on Performance of Glucometer Test Strips , 2005, American Society for Clinical Laboratory Science.