Accurate signal-source localization in brain slices by means of high-density microelectrode arrays

Extracellular recordings by means of high-density microelectrode arrays (HD-MEAs) have become a powerful tool to resolve subcellular details of single neurons in active networks grown from dissociated cells. To extend the application of this technology to slice preparations, we developed models describing how extracellular signals, produced by neuronal cells in slices, are detected by microelectrode arrays. The models help to analyze and understand the electrical-potential landscape in an in vitro HD-MEA-recording scenario based on point-current sources. We employed two modeling schemes, (i) a simple analytical approach, based on the method of images (MoI), and (ii) an approach, based on finite-element methods (FEM). We compared and validated the models with large-scale, high-spatiotemporal-resolution recordings of slice preparations by means of HD-MEAs. We then developed a model-based localization algorithm and compared the performance of MoI and FEM models. Both models provided accurate localization results and a comparable and negligible systematic error, when the point source was in saline, a condition similar to cell-culture experiments. Moreover, the relative random error in the x-y-z-localization amounted only up to 4.3% for z-distances up to 200 μm from the HD-MEA surface. In tissue, the systematic errors of both, MoI and FEM models were significantly higher, and a pre-calibration was required. Nevertheless, the FEM values proved to be closer to the tissue experimental results, yielding 5.2 μm systematic mean error, compared to 22.0 μm obtained with MoI. These results suggest that the medium volume or “saline height”, the brain slice thickness and anisotropy, and the location of the reference electrode, which were included in the FEM model, considerably affect the extracellular signal and localization performance, when the signal source is at larger distance to the array. After pre-calibration, the relative random error of the z-localization in tissue was only 3% for z-distances up to 200 μm. We then applied the model and related detailed understanding of extracellular recordings to achieve an electrically-guided navigation of a stimulating micropipette, solely based on the measured HD-MEA signals, and managed to target spontaneously active neurons in an acute brain slice for electroporation.

[1]  Andreas Hierlemann,et al.  Technologies to Study Action Potential Propagation With a Focus on HD-MEAs , 2019, Front. Cell. Neurosci..

[2]  R. Barrera,et al.  Point charge in a three‐dielectric medium with planar interfaces , 1978 .

[3]  Torsten Bullmann,et al.  Large-Scale Mapping of Axonal Arbors Using High-Density Microelectrode Arrays , 2019, Front. Cell. Neurosci..

[4]  C. Nicholson,et al.  Origin of the apparent tissue conductivity in the molecular and granular layers of the in vitro turtle cerebellum and the interpretation of current source-density analysis. , 1994, Journal of neurophysiology.

[5]  J. Fermaglich Electric Fields of the Brain: The Neurophysics of EEG , 1982 .

[6]  Klas H. Pettersen,et al.  Current-source density estimation based on inversion of electrostatic forward solution: Effects of finite extent of neuronal activity and conductivity discontinuities , 2006, Journal of Neuroscience Methods.

[7]  W. Denk,et al.  Targeted patch-clamp recordings and single-cell electroporation of unlabeled neurons in vivo , 2008, Nature Methods.

[8]  L. Eskola Reflections on the electrostatic characteristics of direct current in an anisotropic medium , 1988 .

[9]  Andreas Hierlemann,et al.  Recording Large Extracellular Spikes in Microchannels along Many Axonal Sites from Individual Neurons , 2015, PloS one.

[10]  Gerhard Hummer,et al.  Helical jackknives control the gates of the double-pore K+ uptake system KtrAB , 2017, eLife.

[11]  David Tsai,et al.  High-channel-count, high-density microelectrode array for closed-loop investigation of neuronal networks , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Alyosha C. Molnar,et al.  A 50µm pitch, 1120-channel, 20kHz frame rate microelectrode array for slice recording , 2013, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[13]  Andreas Hierlemann,et al.  Switch-Matrix-Based High-Density Microelectrode Array in CMOS Technology , 2010, IEEE Journal of Solid-State Circuits.

[14]  Suhasa B. Kodandaramaiah,et al.  Automated whole-cell patch clamp electrophysiology of neurons in vivo , 2012, Nature Methods.

[15]  G. Buzsáki Large-scale recording of neuronal ensembles , 2004, Nature Neuroscience.

[16]  Klas H. Pettersen,et al.  Amplitude variability and extracellular low-pass filtering of neuronal spikes. , 2008, Biophysical journal.

[17]  U. Frey,et al.  The axon initial segment drives the neuron’s extracellular action potential , 2018, bioRxiv.

[18]  Andreas Hierlemann,et al.  Factors affecting blind localization of a glass micropipette using a high-density microelectrode array , 2013, 2013 IEEE SENSORS.

[19]  B. W. van Dijk,et al.  Symmetry considerations in the quasi-static approximation of volume conductor theory , 1991 .

[20]  Norio Matsuki,et al.  Action-Potential Modulation During Axonal Conduction , 2011, Science.

[21]  P. Nunez,et al.  Electric fields of the brain , 1981 .

[22]  Rouhollah Habibey,et al.  A multielectrode array microchannel platform reveals both transient and slow changes in axonal conduction velocity , 2017, Scientific Reports.

[23]  Yuchio Yanagawa,et al.  Transfer of small interfering RNA by single-cell electroporation in cerebellar cell cultures , 2009, Journal of Neuroscience Methods.

[24]  F. Helmchen,et al.  Calcium indicator loading of neurons using single-cell electroporation , 2007, Pflügers Archiv - European Journal of Physiology.

[25]  U. Mitzdorf Current source-density method and application in cat cerebral cortex: investigation of evoked potentials and EEG phenomena. , 1985, Physiological reviews.

[26]  D. B. Heppner,et al.  Considerations of quasi-stationarity in electrophysiological systems. , 1967, The Bulletin of mathematical biophysics.

[27]  U. Frey,et al.  Tracking axonal action potential propagation on a high-density microelectrode array across hundreds of sites , 2013, Nature Communications.

[28]  A. Maccione,et al.  Large-scale, high-resolution electrophysiological imaging of field potentials in brain slices with microelectronic multielectrode arrays , 2012, Front. Neural Circuits.

[29]  C. Nicholson,et al.  Theory of current source-density analysis and determination of conductivity tensor for anuran cerebellum. , 1975, Journal of neurophysiology.

[30]  A. Konnerth,et al.  Dye loading with patch pipettes. , 2009, Cold Spring Harbor Protocols.

[31]  Torbjørn V. Ness,et al.  Impedance Spectrum in Cortical Tissue: Implications for Propagation of LFP Signals on the Microscopic Level , 2017, eNeuro.

[32]  R. Matsumura,et al.  An electrically resistive sheet of glial cells for amplifying signals of neuronal extracellular recordings. , 2016, Applied physics letters.

[33]  Stefano Panzeri,et al.  Modelling and analysis of local field potentials for studying the function of cortical circuits , 2013, Nature Reviews Neuroscience.

[34]  Klas H. Pettersen,et al.  Modeling the Spatial Reach of the LFP , 2011, Neuron.

[35]  Z. Somogyvári,et al.  Model-based source localization of extracellular action potentials , 2005, Journal of Neuroscience Methods.

[36]  Christof Koch,et al.  Electrical Interactions via the Extracellular Potential Near Cell Bodies , 1999, Journal of Computational Neuroscience.

[37]  H Kwan,et al.  Electrical conductivity in cat cerebellar cortex. , 1974, Experimental neurology.

[38]  J. Sarvas Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. , 1987, Physics in medicine and biology.

[39]  B. Roska,et al.  Virus stamping for targeted single-cell infection in vitro and in vivo , 2017, Nature Biotechnology.

[40]  Takuya Sasaki,et al.  The axon as a unique computational unit in neurons , 2013, Neuroscience Research.

[41]  Vijay Viswam,et al.  A 1024-Channel CMOS Microelectrode Array With 26,400 Electrodes for Recording and Stimulation of Electrogenic Cells In Vitro , 2014, IEEE Journal of Solid-State Circuits.

[42]  Gaute T. Einevoll,et al.  Modelling and Analysis of Electrical Potentials Recorded in Microelectrode Arrays (MEAs) , 2015, Neuroinformatics.

[43]  Owe Orwar,et al.  Single-cell electroporation , 2010, Analytical and bioanalytical chemistry.

[44]  Kenneth L. Shepard,et al.  Statistically Reconstructed Multiplexing for Very Dense, High-Channel-Count Acquisition Systems , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[45]  T. Kaneko,et al.  Green fluorescent protein expression and colocalization with calretinin, parvalbumin, and somatostatin in the GAD67‐GFP knock‐in mouse , 2003, The Journal of comparative neurology.

[46]  Suhasa B Kodandaramaiah,et al.  Integration of autopatching with automated pipette and cell detection in vitro. , 2016, Journal of neurophysiology.

[47]  R. O. Jones,et al.  Beyond the method of images—the interaction of charged particles with real surfaces , 1988 .

[48]  Armin Lambacher,et al.  Axonal Transmission in the Retina Introduces a Small Dispersion of Relative Timing in the Ganglion Cell Population Response , 2011, PloS one.

[49]  István Ulbert,et al.  Localization of single‐cell current sources based on extracellular potential patterns: the spike CSD method , 2012, The European journal of neuroscience.

[50]  James R. Wait Current flow into a three-dimensionally anisotropic conductor , 1990 .

[51]  B. Eversmann,et al.  A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity , 2003 .

[52]  Jan Wouters,et al.  Single-cell recording and stimulation with a 16k micro-nail electrode array integrated on a 0.18 μm CMOS chip. , 2012, Lab on a chip.

[53]  Andreas Hierlemann,et al.  Tracking individual action potentials throughout mammalian axonal arbors , 2017, eLife.

[54]  Simon R. Schultz,et al.  Progress in automating patch clamp cellular physiology , 2018, Brain and neuroscience advances.

[55]  C. Koch,et al.  On the origin of the extracellular action potential waveform: A modeling study. , 2006, Journal of neurophysiology.

[56]  Kenneth D Harris,et al.  Improving data quality in neuronal population recordings , 2016, Nature Neuroscience.

[57]  P. Carroll,et al.  Single-cell electroporation of adult sensory neurons for gene screening with RNA interference mechanism , 2008, Journal of Neuroscience Methods.

[58]  Thomas Arnold,et al.  Self-Assembly and Anti-Amyloid Cytotoxicity Activity of Amyloid beta Peptide Derivatives , 2017, Scientific Reports.

[59]  Vijay Viswam,et al.  Electrical Identification and Selective Microstimulation of Neuronal Compartments Based on Features of Extracellular Action Potentials , 2016, Scientific Reports.

[60]  W. Rall Electrophysiology of a dendritic neuron model. , 1962, Biophysical journal.

[61]  U. Frey,et al.  Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies , 2019, Front. Neurosci..

[62]  M. Häusser,et al.  Targeted single-cell electroporation of mammalian neurons in vivo , 2009, Nature Protocols.

[63]  William H. Beyer,et al.  CRC standard mathematical tables , 1976 .

[64]  Edward S. Boyden,et al.  Closed-Loop Real-Time Imaging Enables Fully Automated Cell-Targeted Patch-Clamp Neural Recording In Vivo , 2017, Neuron.

[65]  R. Drenan,et al.  Local application of drugs to study nicotinic acetylcholine receptor function in mouse brain slices. , 2012, Journal of visualized experiments : JoVE.

[66]  Christof Koch,et al.  Using extracellular action potential recordings to constrain compartmental models , 2007, Journal of Computational Neuroscience.

[67]  Luca Berdondini,et al.  Active pixel sensor array for high spatio-temporal resolution electrophysiological recordings from single cell to large scale neuronal networks. , 2009, Lab on a chip.

[68]  D. Schmitt-Landsiedel,et al.  A 128 /spl times/ 128 CMOS bio-sensor array for extracellular recording of neural activity , 2003, 2003 IEEE International Solid-State Circuits Conference, 2003. Digest of Technical Papers. ISSCC..

[69]  G. Shepherd,et al.  Theoretical reconstruction of field potentials and dendrodendritic synaptic interactions in olfactory bulb. , 1968, Journal of neurophysiology.

[70]  U. Frey,et al.  Microelectronic system for high-resolution mapping of extracellular electric fields applied to brain slices. , 2009, Biosensors & bioelectronics.

[71]  Kristina J. Nielsen,et al.  Targeting Single Neuronal Networks for Gene Expression and Cell Labeling In Vivo , 2010, Neuron.

[72]  C. Koch,et al.  The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes , 2012, Nature Reviews Neuroscience.

[73]  Athanasia G. Palasantza,et al.  Electrophysiological, transcriptomic and morphologic profiling of single neurons using Patch-seq , 2015, Nature Biotechnology.

[74]  Norman Dodel,et al.  A Capacitively-Coupled CMOS-MEA with 4225 Recording Sites and 1024 Stimulation Sites , 2014 .

[75]  S. Schultz,et al.  Localising and classifying neurons from high density MEA recordings , 2014, Journal of Neuroscience Methods.

[76]  R. Fox,et al.  Classical Electrodynamics, 3rd ed. , 1999 .

[77]  Simon R. Schultz,et al.  Robotic Automation of In Vivo Two-Photon Targeted Whole-Cell Patch-Clamp Electrophysiology , 2017, Neuron.

[78]  G. Arfken Mathematical Methods for Physicists , 1967 .