Radiation dose modulation techniques in the multidetector CT era: from basics to practice.

Radiation exposure to the patient has become a concern for the radiologist in the multidetector computed tomography (CT) era. With the introduction of faster multidetector CT scanners, various techniques have been developed to reduce the radiation dose to the patient; one method is automatic exposure control (AEC). AEC systems make use of different types of control, including patient-size AEC, z-axis AEC, rotational or angular AEC, or a combination of two or more of these types. AEC systems operate on the basis of several methods: standard deviation, noise index, reference milliamperage, and reference image. A clear understanding of how to use different AEC systems on different multidetector CT scanners will allow users to modulate radiation dose, reduce photon starvation artifacts, and maintain image quality throughout the body. Further development of AEC systems and their successful introduction into clinical practice will require user education and good communication between users and manufacturers.

[1]  T. Mulkens,et al.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. , 2005, Radiology.

[2]  T. Fearon CT dose parameters and their limitations , 2002, Pediatric Radiology.

[3]  P C Shrimpton,et al.  Influence of patient age on normalized effective doses calculated for CT examinations. , 2002, The British journal of radiology.

[4]  C H McCollough,et al.  Calculation of effective dose. , 2000, Medical physics.

[5]  M. Kalra,et al.  Techniques and applications of automatic tube current modulation for CT. , 2004, Radiology.

[6]  D. Brenner,et al.  Estimated risks of radiation-induced fatal cancer from pediatric CT. , 2001, AJR. American journal of roentgenology.

[7]  Hiroshi Niimi,et al.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA , 2004, European Radiology.

[8]  Michael J Pentecost,et al.  American College of Radiology white paper on radiation dose in medicine. , 2007, Journal of the American College of Radiology : JACR.

[9]  W A Kalender,et al.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. , 1999, Medical physics.

[10]  W A Kalender,et al.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. , 1999, Medical physics.

[11]  S. Golding,et al.  Commentary. Radiation dose in CT: are we meeting the challenge? , 2002, The British journal of radiology.

[12]  Thomas B. Shope,et al.  A method for describing the doses delivered by transmission x-ray computed tomography. , 1981 .