Radiant ceiling systems coupled to its environment part 1: Experimental analysis

This paper presents the results of an experimental analysis of the radiant ceiling systems in both heating and cooling modes coupled to its environment (fenestration, walls, internal loads and ventilation system). The main objective of this study is to present the results of the experimental analysis and measurement methods and its discussion. Two test chambers are adapted in a way to reproduce as good as possible the characteristics of the real offices located in Brussels (Belgium). Forty-six tests are performed to observe the influence of parameters such as the mass flow rate, supply water temperature, fenestration and ventilation system effects and thermal load distribution. Laboratory test results show that the influence of surfaces temperatures inside the room, especially the facade, is considerable. Therefore, the system must be evaluated together with its designed environment and not as separate HVAC equipment.

[1]  Néstor Fonseca Diaz,et al.  Methodology for uncertainty calculation of net total cooling effect estimation for rating room air conditioners and packaged terminal air conditioners , 2009 .

[2]  Geoffrey P. Hammond,et al.  Improved data correlations for buoyancy-driven convection in rooms , 1983 .

[3]  Hazim B. Awbi,et al.  Mixed convection from heated room surfaces , 2000 .

[4]  Refet Karadağ The investigation of relation between radiative and convective heat transfer coefficients at the ceiling in a cooled ceiling room , 2009 .

[5]  Joseph Virgone,et al.  Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling , 2009 .

[6]  Martin Behne,et al.  Indoor air quality in rooms with cooled ceilings.: Mixing ventilation or rather displacement ventilation? , 1999 .

[7]  Giovanni Vincenzo Fracastoro,et al.  Experimental and numerical analysis of air and radiant cooling systems in offices , 2009 .

[8]  Stéphane Bertagnolio,et al.  Radiant ceiling systems coupled to its environment part 2: Dynamic modeling and validation , 2010 .

[9]  Mats Sandberg,et al.  Experimental investigation of the velocity field and airflow pattern generated by cooling ceiling beams , 2001 .

[10]  Jelena Srebric,et al.  New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow , 2006 .

[11]  Néstor Fonseca,et al.  Experimental study of the thermal balance of a window, design description , 2007 .