Numerical investigations of the structural behavior of a balloon expandable stent design using finite element method

Abstract This paper discusses some issues regarding the structural behavior of a Balloon-Expandable (BE) stent made of stainless steel material (AISI316L). BE stent is a tubular, often mesh-like, structure which is expanded inside a diseased (stenosed) artery segment to restore blood flow and keep the vessel open following angioplasty. Most of BE stent designs have two fundamental constituents: expandable ring elements, and connecting elements “bridges” which connect adjacent rings together. The stent design is a major factor which determines its reliability during insertion into the blocked artery and throughout the long term in vivo service. The objective of this paper is to study the structural behavior of the stent in order to show the effect of the stent design, especially the geometry of the “bridges” in terms of flexibility, torsion and expansion. The numerical investigation is based on Finite Element Analysis (FEA) using Abaqus© finite element code. It has been demonstrated by FEA that the geometry of the connecting elements “bridges” has a significant impact on the structural behavior of the stent.

[1]  Lorenza Petrini,et al.  On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method. , 2008, Journal of biomechanics.

[2]  P. E. McHugh,et al.  Comparing coronary stent material performance on a common geometric platform through simulated bench testing. , 2012, Journal of the mechanical behavior of biomedical materials.

[3]  Damiano Pasini,et al.  Shape optimization of stress concentration-free lattice for self-expandable Nitinol stent-grafts. , 2012, Journal of biomechanics.

[4]  Huajiang Ouyang,et al.  Shape optimization of coronary artery stent based on a parametric model , 2009 .

[5]  D. Stoeckel,et al.  A survey of stent designs , 2002, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[6]  F Auricchio,et al.  Fatigue life assessment of cardiovascular balloon-expandable stents: a two-scale plasticity-damage model approach. , 2012, Journal of the mechanical behavior of biomedical materials.

[7]  Wei Wu,et al.  Topology optimization of a novel stent platform with drug reservoirs. , 2008, Medical engineering & physics.

[8]  Salim Belouettar,et al.  On high-cycle fatigue of 316L stents , 2014, Computer methods in biomechanics and biomedical engineering.

[9]  Salim Belouettar,et al.  Deployment of a self-expanding stent inside an artery: A finite element analysis , 2012 .

[10]  Pascal Verdonck,et al.  Virtual optimization of self-expandable braided wire stents. , 2009, Medical engineering & physics.

[11]  Kuang-Huei Lee,et al.  Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior , 2012, Comput. Aided Des..

[12]  Min Qi,et al.  An FEA method to study flexibility of expanded coronary stents , 2007 .

[13]  Lorenza Petrini,et al.  Numerical investigation of the intravascular coronary stent flexibility. , 2004, Journal of biomechanics.

[14]  Irfan Kaymaz,et al.  Application Of Kriging Method To Structural Reliability Problems , 2005 .

[15]  Zbigniew Paszenda,et al.  Experimental and numerical biomechanical analysis of vascular stent , 2005 .

[16]  Pascal Verdonck,et al.  Realistic finite element-based stent design: the impact of balloon folding. , 2008, Journal of biomechanics.

[17]  David Taylor,et al.  Fatigue and fracture in materials used for micro-scale biomedical components. , 2006, Bio-medical materials and engineering.

[18]  Sanjay Pant,et al.  Multiobjective design optimisation of coronary stents. , 2011, Biomaterials.