Application of a Novel Metal Artifact Correction Algorithm in Flat-Panel CT After Coil Embolization of Brain Aneurysms: Intraindividual Comparison

PURPOSE To evaluate a novel algorithm for correcting beam hardening artifacts caused by metal implants in computed tomography performed on a C-arm angiography system equipped with a flat panel (FP-CT). MATERIALS AND METHODS 16 datasets of cerebral FP-CT acquisitions after coil embolization of brain aneurysms in the context of acute subarachnoid hemorrhage have been reconstructed by applying a soft tissue kernel with and without a novel reconstruction filter for metal artifact correction. Image reading was performed in multiplanar reformations (MPR) in average mode on a dedicated radiological workplace in comparison to the preinterventional native multisection CT (MS-CT) scan serving as the anatomic gold standard. Two independent radiologists performed image scoring following a defined scale in direct comparison of the image data with and without artifact correction. For statistical analysis, a random intercept model was calculated. RESULTS The inter-rater agreement was very high (ICC = 86.3 %). The soft tissue image quality and visualization of the CSF spaces at the level of the implants was substantially improved. The additional metal artifact correction algorithm did not induce impairment of the subjective image quality in any other brain regions. CONCLUSION Adding metal artifact correction to FP-CT in an acute postinterventional setting helps to visualize the close vicinity of the aneurysm at a generally consistent image quality.

[1]  T. Struffert,et al.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model , 2011, European Radiology.

[2]  Hesham Morsi,et al.  Angiographic CT in cerebrovascular stenting. , 2005, AJNR. American journal of neuroradiology.

[3]  N. Noordhoek,et al.  Contrast-Enhanced Angiographic Cone-Beam CT of Cerebrovascular Stents: Experimental Optimization and Clinical Application , 2010, American Journal of Neuroradiology.

[4]  Raphaël Blanc,et al.  Intravenous flat-detector CT angiography in acute ischemic stroke management , 2012, Neuroradiology.

[5]  F. Clarençon,et al.  Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms , 2012, Neuroradiology.

[6]  James V. Byrne,et al.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology , 2010, Neuroradiology.

[7]  W. Kalender,et al.  Flat-detector computed tomography (FD-CT) , 2007, European Radiology.

[8]  Marc Saake,et al.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results , 2011, European Radiology.

[9]  P. D. De with,et al.  High-resolution 3D X-ray imaging of intracranial nitinol stents , 2011, Neuroradiology.

[10]  [Flat-detector computed tomography in diagnostic and interventional neuroradiology]. , 2009, Der Radiologe.

[11]  T. Struffert,et al.  Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents , 2012, Neuroradiology.

[12]  O. Ganslandt,et al.  Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT , 2008, Neuroradiology.

[13]  Oliver Ganslandt,et al.  Optimized angiographic computed tomography with intravenous contrast injection: an alternative to conventional angiography in the follow-up of clipped aneurysms? , 2012, Journal of neurosurgery.

[14]  J. Hornegger,et al.  Technical feasibility of 2D–3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study , 2009, Neuroradiology.

[15]  P. Dechent,et al.  Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms—a comparative study with DSA and TOF-MRA , 2009, European Radiology.

[16]  M. Knauth,et al.  Feasibility of Angiographic CT in Peri-Interventional Diagnostic Imaging: A Comparative Study with Multidetector CT , 2010, American Journal of Neuroradiology.

[17]  A M Malek,et al.  Parent Vessel Size and Curvature Strongly Influence Risk of Incomplete Stent Apposition in Enterprise Intracranial Aneurysm Stent Coiling , 2011, American Journal of Neuroradiology.

[18]  Y. Kyriakou,et al.  Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results , 2013, Neuroradiology.

[19]  M. Knauth,et al.  Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting , 2008, Neuroradiology.

[20]  V. Rohde,et al.  Feasibility of Flat Panel Angiographic CT after Intravenous Contrast Agent Application in the Postoperative Evaluation of Patients with Clipped Aneurysms , 2011, American Journal of Neuroradiology.

[21]  D. Babic,et al.  Brain imaging with a flat detector C-arm , 2008, Neuroradiology.

[22]  V. Rohde,et al.  IvACT after aneurysm clipping as an alternative to digital subtraction angiography--first experiences. , 2010, Central European neurosurgery.

[23]  T Struffert,et al.  Rotational Flat-Panel Computed Tomography in Diagnostic and Interventional Neuroradiology , 2008, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[24]  T. Struffert,et al.  Angiographic CT with Intravenous Contrast Injection Compared with Conventional Rotational Angiography in the Diagnostic Work-Up of Cerebral Aneurysms , 2012, American Journal of Neuroradiology.

[25]  W A Kalender,et al.  Metal Artifact Reduction for Clipping and Coiling in Interventional C-Arm CT , 2010, American Journal of Neuroradiology.