Quantification of the Passive Mechanical Properties of the Resting Platelet

AbstractSudden coronary artery occlusion is one of the leading causes of death. Several in vitro models have been used to study the relationship between hemodynamic forces and platelet function. However, very few in vivo studies exist that fully explore this relationship due to the lack of rheologic data for the platelet. For this purpose, micropipette aspiration techniques were used in the present study to determine the mechanical properties of platelets. The data were analyzed by two mathematical models: (1) an erythrocyte-type membrane model which yielded a platelet shear modulus of 0.03 ± 0.01 dyn cm-1 (mean±SD) and a viscous modulus of 0.12 ± 0.04 dyn s cm-1. (2) An endothelial-type cell model which approximated the platelet Young’s modulus to be 1.7 ± 0.6 × 103 dyn cm-2 with a viscous modulus of 1.0 ± 0.5 × 104 dyn s cm-2. The endothelial-type cell model more accurately describes the mechanics occurring at the micropipette tip and permits more appropriate assumptions to be made in quantifying the rheologic properties of a platelet. Results from this study can be integrated into numerical models of blood flow in stenosed coronary arteries to elucidate the impact of local hemodynamics on platelets and thrombus formation in coronary artery disease. © 1998 Biomedical Engineering Society. PAC98: 8722-q, 8745Ft, 8710+e

[1]  J. White,et al.  The platelet open canalicular system: a final common pathway. , 1991, Blood cells.

[2]  R M Nerem,et al.  Application of the micropipette technique to the measurement of cultured porcine aortic endothelial cell viscoelastic properties. , 1990, Journal of biomechanical engineering.

[3]  R. Virmani,et al.  Coronary plaque erosion without rupture into a lipid core. A frequent cause of coronary thrombosis in sudden coronary death. , 1996, Circulation.

[4]  P K Hansma,et al.  Measuring the viscoelastic properties of human platelets with the atomic force microscope. , 1996, Biophysical journal.

[5]  E. Evans,et al.  Intrinsic material properties of the erythrocyte membrane indicated by mechanical analysis of deformation , 1975 .

[6]  S. Usami,et al.  Prostaglandin E1 and dibutyryl cyclic AMP enhance platelet resistance to deformation. , 1991, Thrombosis research.

[7]  R M Nerem,et al.  The application of a homogeneous half-space model in the analysis of endothelial cell micropipette measurements. , 1988, Journal of biomechanical engineering.

[8]  G. Rao,et al.  Aspirin Treatment Reduces Platelet Resistance to Deformation , 1987, Arteriosclerosis.

[9]  S Chien,et al.  Theoretical and experimental studies on viscoelastic properties of erythrocyte membrane. , 1978, Biophysical journal.

[10]  R M Hochmuth Measuring the mechanical properties of individual human blood cells. , 1993, Journal of biomechanical engineering.

[11]  H. Goldsmith,et al.  Platelet aggregation in poiseuille flow: I. A double infusion technique. , 1984, Microvascular research.

[12]  J. Moake,et al.  Platelets and shear stress. , 1996, Blood.

[13]  E. Evans,et al.  New membrane concept applied to the analysis of fluid shear- and micropipette-deformed red blood cells. , 1973, Biophysical journal.

[14]  J. White,et al.  Comparison of bovine and human platelet deformability, using micropipette elastimetry. , 1989, American Journal of Veterinary Research.

[15]  J. White,et al.  Micropipette aspiration of human platelets: influence of microtubules and actin filaments on deformability. , 1984, Blood.

[16]  H. Goldsmith,et al.  Platelet aggregation in poiseuille flow: II. Effect of shear rate. , 1984, Microvascular research.

[17]  S. Burris,et al.  Micropipette aspiration of human blood platelets: a defect in Bernard- Soulier's syndrome , 1984 .

[18]  J. White Platelet membrane ultrastructure and its changes during platelet activation. , 1988, Progress in clinical and biological research.

[19]  J. Hartwig,et al.  The cytoskeleton of the resting human blood platelet: structure of the membrane skeleton and its attachment to actin filaments , 1991, The Journal of cell biology.

[20]  Properties of red blood cells preserved in SAG-mannitol +/- L-carnitine , 1998 .

[21]  R. Skalak,et al.  Passive mechanical properties of human leukocytes. , 1981, Biophysical journal.

[22]  Goldsmith Hl The effects of flow and fluid mechanical stress on red cells and platelets. , 1974 .

[23]  J. Moake,et al.  Platelets and shear stress. , 1996 .

[24]  E. Evans,et al.  Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration. , 1989, Biophysical journal.

[25]  E. Evans A new material concept for the red cell membrane. , 1973, Biophysical journal.

[26]  R M Nerem,et al.  Viscoelastic properties of cultured porcine aortic endothelial cells exposed to shear stress. , 1996, Journal of biomechanics.

[27]  J. White,et al.  Micropipette aspiration of human platelets: influence of rewarming on deformability of chilled cells. , 1986, The Journal of laboratory and clinical medicine.

[28]  H. Goldsmith The effects of flow and fluid mechanical stress on red cells and platelets. , 1974, Transactions - American Society for Artificial Internal Organs.

[29]  E. Evans,et al.  Cortical shell-liquid core model for passive flow of liquid-like spherical cells into micropipets. , 1989, Biophysical journal.

[30]  J. White,et al.  Micropipette Aspiration of Human Platelets after Exposure to Aggregating Agents , 1986, Arteriosclerosis.