Optimized star sensors laboratory calibration method using a regularization neural network.

High-precision ground calibration is essential to ensure the performance of star sensors. However, the complex distortion and multi-error coupling have brought great difficulties to traditional calibration methods, especially for large field of view (FOV) star sensors. Although increasing the complexity of models is an effective way to improve the calibration accuracy, it significantly increases the demand for calibration data. In order to achieve high-precision calibration of star sensors with large FOV, a novel laboratory calibration method based on a regularization neural network is proposed. A multi-layer structure neural network is designed to represent the mapping of the star vector and the corresponding star point coordinate directly. To ensure the generalization performance of the network, regularization strategies are incorporated into the net structure and the training algorithm. Simulation and experiment results demonstrate that the proposed method can achieve high precision with less calibration data and without any other priori information. Compared with traditional methods, the calibration error of the star sensor decreased by about 30%. The proposed method can satisfy the precision requirement for large FOV star sensors.

[1]  D Lu,et al.  Application of CMOS APS star tracker with large FOV in attitude and angular velocity determination , 2008, SPIE/COS Photonics Asia.

[2]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[3]  Timothy A. Clarke,et al.  Comparison of some techniques for the subpixel location of discrete target images , 1994, Other Conferences.

[4]  Uwe Schmidt ASTRO APS - The Next Generation Hi-Rel Star Tracker Based on Active Pixel Sensor Technology , 2005 .

[5]  Hua Xie,et al.  Compensation with models for the optics design for a large FOV star sensor , 2004, SPIE Astronomical Telescopes + Instrumentation.

[6]  Haibo Liu,et al.  Distortion model for star tracker , 2010, International Symposium on Precision Engineering Measurement and Instrumentation.

[7]  Geoffrey E. Hinton,et al.  Learning representations by back-propagating errors , 1986, Nature.

[8]  Fei Xing,et al.  Laboratory calibration of star tracker with brightness independent star identification strategy , 2006 .

[9]  Ludovic Blarre,et al.  High accuracy Sodern Star Trackers: Recent improvements proposed on SED36 and HYDRA Star Trackers , 2006 .

[10]  Carl Christian Liebe,et al.  Accuracy performance of star trackers - a tutorial , 2002 .

[11]  Jun Zhang,et al.  Laboratory calibration of star sensor with installation error using a nonlinear distortion model , 2014 .

[12]  Cullen Schaffer,et al.  Technical Note: Selecting a Classification Method by Cross-Validation , 1993, Machine Learning.

[13]  Jian Sun,et al.  Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification , 2015, 2015 IEEE International Conference on Computer Vision (ICCV).

[14]  Paul R. Cohen,et al.  Camera Calibration with Distortion Models and Accuracy Evaluation , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[15]  Fang Jiancheng,et al.  A method of optimization for the distorted model of star map based on improved genetic algorithm , 2011 .

[16]  Jian Li,et al.  Star sensor calibration based on integrated modelling with intrinsic and extrinsic parameters , 2014 .

[17]  Jie Jiang,et al.  High-accuracy star sensor calibration based on intrinsic and extrinsic parameter decoupling , 2015 .

[18]  C. Liebe Star trackers for attitude determination , 1995 .