Biomechanics of the front abdominal wall as a potential factor leading to recurrence with laparoscopic ventral hernia repair

BackgroundIntraabdominal pressure often is blamed as the cause of mesh–fascia junction failure after laparoscopic ventral hernia repair. Stretching of the mesh during a cough or defecation may lead to recurrence. Little is known about the movements of mesh in the abdominal cavity after this operation. This study investigated the front abdominal wall to describe its elasticity in vivo and searched for elongations that possibly stretched an implanted mesh, thereby causing fixation failure and subsequent recurrence.MethodsTo measure front abdominal wall elongations, a model of fascia movements was created. Eight healthy volunteers were measured during exercise to determine the extent of elongations in their front abdominal wall. Videos were analyzed in three positions to create a mathematical shell structure. A computerized model based on the net movement of nodes was calculated to determine the axes and values for maximum elongations.ResultsThe largest average elongations were measured for the upper midline (32.08%) and the transverse line in the low lateral area (34.06%). The maximum values for these lines were larger than 100% for the middle line (133.78%) and exceeded 50% for the entire middle line. The values for the horizontal lines did not reach 10% at any level. According to these data, areas of both high and low elasticity were defined.ConclusionsThe presented experiment adds new parameters to the understanding of in vivo mesh behavior. Elongation of the front abdominal wall may stretch implanted mesh and could be a cause of recurrence in cases of insufficient fixation.

[1]  K. Junge,et al.  Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants , 2001, Hernia.

[2]  L. Stassen,et al.  Prolonged abdominal wall pain caused by transfascial sutures used in the laparoscopic repair of incisional hernia , 2003, Surgical Endoscopy And Other Interventional Techniques.

[3]  Andreas Prescher,et al.  Anisotropy of human linea alba: a biomechanical study. , 2005, The Journal of surgical research.

[4]  M. Śmietański,et al.  Assessment of usefulness exhibited by different tacks in laparoscopic ventral hernia repair , 2007, Surgical Endoscopy.

[5]  M. Franz,et al.  Mesh incisional herniorrhaphy increases abdominal wall elastic properties: a mechanism for decreased hernia recurrences in comparison with suture repair. , 2006, Surgery.

[6]  Brent D. Matthews,et al.  Pooled data analysis of laparoscopic vs. open ventral hernia repair: 14 years of patient data accrual , 2007, Surgical Endoscopy.

[7]  C. Bellows,et al.  Infiltration of Suture Sites With Local Anesthesia for Management of Pain Following Laparoscopic Ventral Hernia Repairs: a Prospective Randomized Trial , 2006, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[8]  T. Flanagan,et al.  Biomechanical analyses of overlap and mesh dislocation in an incisional hernia model in vitro. , 2007, Surgery.

[9]  C. Hollinsky,et al.  Measurement of the tensile strength of the ventral abdominal wall in comparison with scar tissue. , 2007, Clinical biomechanics.

[10]  K. Junge,et al.  Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair , 2008, Surgical Endoscopy.

[11]  E. Schoenmaeckers,et al.  Recurrences after laparoscopic repair of ventral and incisional hernia: lessons learned from 505 repairs , 2009, Surgical Endoscopy.

[12]  M. Śmietański,et al.  Laparoscopic ventral hernia repair using Proceed® mesh – three-year follow-up of the initial group of patients , 2008 .

[13]  A. Caliebe,et al.  Open versus laparoscopic incisional hernia repair: something different from a meta-analysis , 2008, Surgical Endoscopy.

[14]  E. Schoenmaeckers,et al.  Mesh-fixation method and pain and quality of life after laparoscopic ventral or incisional hernia repair: a randomized trial of three fixation techniques , 2009, Surgical Endoscopy.

[15]  Stephen H M Brown,et al.  A comparison of ultrasound and electromyography measures of force and activation to examine the mechanics of abdominal wall contraction. , 2010, Clinical biomechanics.

[16]  J. Allé,et al.  Eighty-five redo surgeries after 733 laparoscopic treatments for ventral and incisional hernia: adhesion and recurrence analysis , 2010, Hernia.

[17]  Brent D. Matthews,et al.  Physicomechanical evaluation of absorbable and nonabsorbable barrier composite meshes for laparoscopic ventral hernia repair , 2011, Surgical Endoscopy.

[18]  Czesław Szymczak,et al.  Modeling of the fascia-mesh system and sensitivity analysis of a junction force after a laparoscopic ventral hernia repair , 2010 .

[19]  Shajay Bhooshan,et al.  Use of sub-division surfaces in architectural form-finding and procedural modelling , 2011, SpringSim.

[20]  Czesław Szymczak,et al.  Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair. , 2012, Clinical biomechanics.