A low-power electronic instrumentation for multi-parametric diabetes mellitus analysis

We present a small, compact and low-power electronic instrumentation for a point-of-care (PoC) device for the early diagnosis of diabetes mellitus and associated risk factors. The presented system consists of a low-power 4-channel potentiostat, a transducer with 4 separate electrochemical cells featuring different biosensors, and a low-cost printed battery. The system is designed to measure key parameters on diabetes mellitus analysis, such as: glucose, cholesterol and triglycerides. It has been designed as a disposable device using a single blood drop to quantify these parameters, enhancing disposition decision time and improving patient satisfaction when compared with current analytical methodology. The electronic instrumentation has been designed to simultaneously control and read the measurement of the 4 different sensors on the transducer block/chip. In this paper, we present the previous evaluation of the system through different cyclic voltammetry and chronoamperometry analysis compared with a commercial multichannel potentiostat 1030B from CH Instruments. The system presents accurate and reliable performance powered by a printed electrochemical battery.

[1]  George M. Whitesides,et al.  A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing , 2012, Science Translational Medicine.

[2]  N F de Rooij,et al.  In-vivo behaviour of hypodermically implanted microfabricated glucose sensors. , 1991, Biosensors & bioelectronics.

[3]  Annette Rebel,et al.  The Accuracy of Point-of-Care Glucose Measurements , 2012 .

[4]  S. Piletsky,et al.  In vitro diagnostics in diabetes: meeting the challenge. , 1999, Clinical chemistry.

[5]  W Zingg,et al.  Clinical Control of Diabetes by the Artificial Pancreas , 1974, Diabetes.

[6]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[7]  C Henry Getting under the skin: implantable glucose sensors. , 1998, Analytical chemistry.

[8]  Esteve Juanola-Feliu,et al.  A portable point-of-care device for multi-parametric diabetes mellitus analysis , 2015, IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society.

[9]  Meng Xiao,et al.  An integrated microfluidic device utilizing dielectrophoresis and multiplex array PCR for point-of-care detection of pathogens. , 2014, Lab on a chip.

[10]  Bernhard Lendl,et al.  Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensor , 2013 .

[11]  Clarence W. de Silva,et al.  Recent advances in MEMS sensor technology – biomedical applications , 2012, IEEE Instrumentation & Measurement Magazine.

[12]  Jens Ducrée,et al.  Integration of functional materials and surface modification for polymeric microfluidic systems , 2013 .

[13]  Ping Wang,et al.  Printed microwells with highly stable thin-film enzyme coatings for point-of-care multiplex bioassay of blood samples. , 2015, The Analyst.

[14]  Moshe Kam,et al.  Improved blood glucose estimation through multi-sensor fusion , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  R. Gomis,et al.  Prevalence of diabetes mellitus and impaired glucose regulation in Spain: the Di@bet.es Study , 2011, Diabetologia.

[16]  Robert C. Bast,et al.  A Multiplexable, Microfluidic Platform for the Rapid Quantitation of a Biomarker Panel for Early Ovarian Cancer Detection at the Point-of-Care , 2014, Cancer Prevention Research.

[17]  Eun-Hyung Yoo,et al.  Glucose Biosensors: An Overview of Use in Clinical Practice , 2010, Sensors.

[18]  A StJohn,et al.  Existing and Emerging Technologies for Point-of-Care Testing. , 2014 .

[19]  Marja-Riitta Taskinen,et al.  New insights into the pathophysiology of dyslipidemia in type 2 diabetes. , 2015, Atherosclerosis.

[20]  Jordi Colomer-Farrarons,et al.  Bioelectronics for Amperometric Biosensors , 2013 .

[21]  G. Bakris,et al.  Higher prevalence of anemia with diabetes mellitus in moderate kidney insufficiency: The Kidney Early Evaluation Program. , 2005, Kidney international.

[22]  Kim E. Sapsford,et al.  Evaluation of Optical Detection Platforms for Multiplexed Detection of Proteins and the Need for Point-of-Care Biosensors for Clinical Use , 2014, Sensors.

[23]  Andrew St John,et al.  Existing and Emerging Technologies for Point-of-Care Testing. , 2014, The Clinical biochemist. Reviews.

[24]  G. W. Shaw,et al.  Potentially-implantable, amperometric glucose sensors with mediated electron transfer: improving the operating stability. , 1989, Biosensors.

[25]  J. Griffith,et al.  Anemia as a risk factor for cardiovascular disease and all-cause mortality in diabetes: the impact of chronic kidney disease. , 2005, Journal of the American Society of Nephrology : JASN.

[26]  Josep M. Cirera,et al.  Small-volume multiparametric electrochemical detection at low cost polymeric devices featuring nanoelectrodes , 2015, Microtechnologies for the New Millennium.