A Modified Active Power Control Scheme for Enhanced Operation of PMSG-Based WGs

This paper emphasizes the development of a simplified active power control scheme for enhanced operation of grid integrated permanent magnet synchronous generator based wind-driven generators (WGs). An active power reference generation scheme is proposed for the machine side converter (MSC) to inject active power into the grid even under grid disturbances, without violating system components rating. In this scheme, the controller employed for MSC adjusts the active power captured proportionate to the drop in the grid voltage upon considering wind speed and rotor speed. Furthermore, unlike dual vector control scheme, the grid side converter controller is implemented in a positive synchronous frame with the proposed current oscillation cancellation scheme to suppress the oscillations in dc-link voltage, active and reactive power of the grid and to obtain symmetrical sinusoidal grid current. Extensive analytical simulation has been carried out in PSCAD/ EMTDC to validate the superiority of proposed control scheme over the conventional schemes when WG is subjected to various grid disturbances. The reduced percentage of oscillation in the system parameters such as dc-link voltage and grid active power confirms the efficacy of the proposed method when compared with the conventional control techniques.

[1]  Shuhui Li,et al.  Optimal and Direct-Current Vector Control of Direct-Driven PMSG Wind Turbines , 2012, IEEE Transactions on Power Electronics.

[2]  Heung-Geun Kim,et al.  LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization , 2012, IEEE Transactions on Power Electronics.

[3]  Weidong Xiao,et al.  A novel transient control strategy for VSC-HVDC connecting offshore wind power plant , 2014, 2015 IEEE Power & Energy Society General Meeting.

[4]  H. Polinder,et al.  Comparison of direct-drive and geared generator concepts for wind turbines , 2005, IEEE International Conference on Electric Machines and Drives, 2005..

[5]  Mukhtiar Singh,et al.  Grid synchronisation with harmonics and reactive power compensation capability of a permanent magnet synchronous generator-based variable speed wind energy conversion system , 2011 .

[6]  T Senjyu,et al.  A Coordinated Control Method to Smooth Wind Power Fluctuations of a PMSG-Based WECS , 2011, IEEE Transactions on Energy Conversion.

[7]  S.M. Muyeen,et al.  A Variable Speed Wind Turbine Control Strategy to Meet Wind Farm Grid Code Requirements , 2010, IEEE Transactions on Power Systems.

[8]  Anca Daniela Hansen,et al.  Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults , 2009 .

[9]  M. Chinchilla,et al.  Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid , 2006, IEEE Transactions on Energy Conversion.

[10]  Kai Zhang,et al.  Control and Monitoring for Grid-Friendly Wind Turbines: Research Overview and Suggested Approach , 2015, IEEE Transactions on Power Electronics.

[11]  Bin Wu,et al.  Use of Stored Energy in PMSG Rotor Inertia for Low-Voltage Ride-Through in Back-to-Back NPC Converter-Based Wind Power Systems , 2013, IEEE Transactions on Industrial Electronics.

[12]  H. H. Hanafy,et al.  Enhancement low-voltage ride through capability of permanent magnet synchronous generator-based wind turbines using interval type-2 fuzzy control , 2016 .

[13]  F. Valenciaga,et al.  Multiple-input–multiple-output high-order sliding mode control for a permanent magnet synchronous generator wind-based system with grid support capabilities , 2015 .

[14]  J Pou,et al.  Variable-Frequency Grid-Sequence Detector Based on a Quasi-Ideal Low-Pass Filter Stage and a Phase-Locked Loop , 2010, IEEE Transactions on Power Electronics.

[15]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[16]  J. F. Conroy,et al.  Low-voltage ride-through of a full converter wind turbine with permanent magnet generator , 2007 .

[17]  Dong-Choon Lee,et al.  Advanced Fault Ride-Through Technique for PMSG Wind Turbine Systems Using Line-Side Converter as STATCOM , 2013, IEEE Transactions on Industrial Electronics.

[18]  Math Bollen,et al.  Voltage dips at the terminals of wind power installations , 2005 .

[19]  Bin Wu,et al.  Unified Power Control for PMSG-Based WECS Operating Under Different Grid Conditions , 2011, IEEE Transactions on Energy Conversion.