Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops.

Ion evaporation is an essential step in the formation of charged ions from electrosprays, yet many aspects of the process are poorly understood. The ion evaporation kinetics of the 1-ethyl-3-methyl-imidazolium+ (EMI+) based ionic liquids (ILs) EMI-BF4, EMI-bis(perfluoroethylsulfonyl)imide, EMI-bis(trifluoromethylsulfonyl)imide and EMI-tris(trifluoromethylsulfonyl)methide (EMI-Methide) are studied by tandem ion mobility-mass spectrometry (IMS-MS) of IL nanodrop residues from positive and negative electrosprays of IL-acetonitrile solutions. Two-dimensional (2D) IMS-MS spectra are obtained using a differential mobility analyzer (DMA) coupled to a commercial quadrupole-time-of-flight mass spectrometer. Nanodrops of different charge states (z=1,2,...,10,...) are separated into distinct bands in 2D DMA-MS spectra, allowing for determination of both nanodrop size (radius) and charge. With the exception of negatively charged EMI-BF4, all clusters observed are charged below the Rayleigh limit of both the ILs and acetonitrile, showing that the charge loss mechanism is ion evaporation. Solvation energies, DeltaG, of evaporating ions from acetonitrile are inferred from radius and charge state data. With the exclusion of EMI-BF4 in negative mode (DeltaG>1.84 eV), all are in the 1.54-1.65 eV range, considerably lower than previously reported for tetra-alkyl ammonium salts in formamide. Measured size distributions of EMI-Methide nanodrops agree with those predicted by ion evaporation theory, though with narrower widths observed for doubly and singly charged nanodrops.

[1]  J. M. Peters Rayleigh's electrified water drops , 1980 .

[2]  Christopher J. Hogan,et al.  Combined charged residue-field emission model of macromolecular electrospray ionization. , 2009, Analytical chemistry.

[3]  C. Enke,et al.  Practical implications of some recent studies in electrospray ionization fundamentals. , 2001, Mass spectrometry reviews.

[4]  M. Mann,et al.  Electrospray ionization for mass spectrometry of large biomolecules. , 1989, Science.

[5]  B. Ku,et al.  Cluster Ion Formation in Electrosprays of Acetonitrile Seeded with Ionic Liquids , 2004 .

[6]  K. T. Whitby,et al.  Aerosol classification by electric mobility: apparatus, theory, and applications , 1975 .

[7]  P. Lozano,et al.  Effect of liquid properties on electrosprays from externally wetted ionic liquid ion sources , 2007 .

[8]  J. F. D. L. Mora,et al.  Energy distribution and spatial structure of electrosprays of ionic liquids in vacuo , 2004 .

[9]  F. Higuera,et al.  Flow rate and electric current emitted by a Taylor cone , 2003, Journal of Fluid Mechanics.

[10]  M. Gamero-Castaño,et al.  Mechanisms of electrospray ionization of singly and multiply charged salt clusters , 2000 .

[11]  Richard D. Smith,et al.  An IMS-IMS analogue of MS-MS. , 2006, Analytical chemistry.

[12]  Edward A. Mason,et al.  The mobility and diffusion of ions in gases , 1973 .

[13]  C. Enke,et al.  A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes. , 1997, Analytical chemistry.

[14]  M. Cloupeau,et al.  Electrostatic spraying of liquids in cone-jet mode , 1989 .

[15]  B. Thomson,et al.  The potential of differential mobility analysis coupled to MS for the study of very large singly and multiply charged proteins and protein complexes in the gas phase. , 2006, Biotechnology journal.

[16]  Christopher J. Hogan,et al.  Charge carrier field emission determines the number of charges on native state proteins in electrospray ionization. , 2008, Journal of the American Chemical Society.

[17]  J. F. D. L. Mora,et al.  Ionic Propulsion Based on Heated Taylor Cones of Ionic Liquids , 2003 .

[18]  Manuel Gamero-Castaño,et al.  Source of heavy molecular ions based on Taylor cones of ionic liquids operating in the pure ion evaporation regime , 2003 .

[19]  M. Gamero-Castaño,et al.  Ammonium Electrolytes Quench Ion Evaporation in Colloidal Propulsion , 2004 .

[20]  F. Higuera,et al.  Ion evaporation from Taylor cones of propylene carbonate mixed with ionic liquids , 2007, Journal of Fluid Mechanics.

[21]  D. Clemmer,et al.  Ion mobility spectrometry/mass spectrometry snapshots for assessing the molecular compositions of complex polymeric systems. , 2008, Analytical chemistry.

[22]  P. Kebarle A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry. , 2000, Journal of mass spectrometry : JMS.

[23]  Yukihiro Yoshida,et al.  Taylor cones of ionic liquids from capillary tubes as sources of pure ions: The role of surface tension and electrical conductivity , 2007, 2402.13668.

[24]  B. Thomson,et al.  Tandem mobility mass spectrometry study of electrosprayed tetraheptyl ammonium bromide clusters , 2005, Journal of the American Society for Mass Spectrometry.

[25]  Christopher J. Hogan,et al.  Charged droplet dynamics in the submicrometer size range. , 2009, The journal of physical chemistry. B.

[26]  I. G. Loscertales,et al.  Experiments on the kinetics of field evaporation of small ions from droplets , 1995 .

[27]  J. V. Iribarne,et al.  Field induced ion evaporation from liquid surfaces at atmospheric pressure , 1979 .

[28]  J. Fenn,et al.  A continuum model for ion evaporation from a drop: effect of curvature and charge on ion solvation energy , 2000 .

[29]  Richard D. Smith,et al.  Control of ion distortion in field asymmetric waveform ion mobility spectrometry via variation of dispersion field and gas temperature. , 2008, Analytical chemistry.

[30]  Manuel Martinez-Sanchez,et al.  On the dynamic response of externally wetted ionic liquid ion sources , 2005 .

[31]  B. Ku,et al.  Relation between Electrical Mobility, Mass, and Size for Nanodrops 1–6.5 nm in Diameter in Air , 2009 .

[32]  Paulo Lozano,et al.  Ionic liquid ion sources: characterization of externally wetted emitters. , 2005, Journal of colloid and interface science.

[33]  Manuel Gamero-Castaño,et al.  Direct measurement of ion evaporation kinetics from electrified liquid surfaces , 2000 .

[34]  J. Mora,et al.  The current emitted by highly conducting Taylor cones , 1994, Journal of Fluid Mechanics.

[35]  J. Mora,et al.  Differential mobility analysis of molecular ions and nanometer particles , 1998 .

[36]  Yukihiro Yoshida,et al.  Surface tension measurements of highly conducting ionic liquids , 2006 .

[37]  A. Gomez,et al.  Charge and fission of droplets in electrostatic sprays , 1994 .

[38]  Marco Fioroni,et al.  Chirally directed formation of nanometer-scale proline clusters. , 2006, Journal of the American Chemical Society.

[39]  Sir William Thomson F.R.S. LX. On the equilibrium of vapour at a curved surface of liquid , 1871 .

[40]  J. Mora,et al.  Molecular monodisperse mobility and mass standards from electrosprays of tetra-alkyl ammonium halides , 2005 .

[41]  J. V. Iribarne,et al.  On the evaporation of small ions from charged droplets , 1976 .

[42]  Gamero-Castano,et al.  Kinetics of small ion evaporation from the charge and mass distribution of multiply charged clusters in electrosprays , 2000, Journal of mass spectrometry : JMS.

[43]  S. Valentine,et al.  IMS-IMS and IMS-IMS-IMS/MS for separating peptide and protein fragment ions. , 2006, Analytical chemistry.

[44]  Paulo Lozano,et al.  Energy properties of an EMI-Im ionic liquid ion source , 2006 .

[45]  D. Levandier,et al.  Vacuum electrospray ionization study of the ionic liquid, [Emim][Im] , 2007 .

[46]  B. Thomson,et al.  Charge-induced unfolding of multiply charged polyethylene glycol ions. , 2004, Journal of the American Chemical Society.