Leak detection and isolation using an observer based on robust sliding mode differentiators

A Leak Detection and Isolation (LDI) algorithm with a State Observer is designed and tested in simulation to locate a water-leak on a pipeline. Most of the works presented in the literature make some linearization in the model limiting the performance of the approach. In order to avoid this situation, in this work, the State Estimation is designed with the nonlinear model using an observer based on robust sliding mode differentiators. The approach assumes only flow and pressure sensors at the ends of the duct, and simulation results with synthetic data obtained from a pipeline simulator are presented to assess the method efficiency. The proposed scheme ensures finite time convergence of the observer and the reduction of chattering effect.

[1]  James A. Liggett,et al.  What Is Hydraulic Engineering , 2002 .

[2]  A. Y. Allidina,et al.  Leak detection and location in gas pipelines , 1988 .

[3]  S. Drakunov Adaptive quasioptimal filter with discontinuous parameters , 1984 .

[4]  M. Fliess,et al.  Nonlinear observability, identifiability, and persistent trajectories , 1991, [1991] Proceedings of the 30th IEEE Conference on Decision and Control.

[5]  Hao-Chi Chang,et al.  Sliding mode control on electro-mechanical systems , 1999 .

[6]  O. Begovich,et al.  Examples of pipeline monitoring with nonlinear observers and real-data validation , 2011 .

[7]  S. Drakunov Sliding-mode observers based on equivalent control method , 1992, [1992] Proceedings of the 31st IEEE Conference on Decision and Control.

[8]  A. Levant Robust exact differentiation via sliding mode technique , 1998 .

[9]  Vadim I. Utkin,et al.  Sliding mode control , 2004 .

[10]  Ofelia Begovich,et al.  Direct observer design for leak detection and estimation in pipelines , 2007, 2007 European Control Conference (ECC).

[11]  Cristina Verde Accommodation of Multi-Leak Positions in a Pipeline , 2003 .

[12]  Maria Cristina Verde Rodarte Accommodation of multi-leak location in a pipeline , 2005 .

[13]  Rolf Isermann,et al.  Leak Detection Methods for Pipelines , 1984 .

[14]  A. Krener,et al.  Nonlinear controllability and observability , 1977 .

[15]  Nahum Shimkin,et al.  Nonlinear Control Systems , 2008 .

[16]  Didier Georges,et al.  Multi-leak estimator for pipelines based on an orthogonal collocation model , 2009, Proceedings of the 48h IEEE Conference on Decision and Control (CDC) held jointly with 2009 28th Chinese Control Conference.

[17]  O. Begovich,et al.  Online implementation of a leak isolation algorithm in a plastic pipeline prototype , 2012 .