Impedance plethysmography in the diagnosis of arterial and venous disease

The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have now demonstrated a direct relationship between electrical impedance changes and limb volume changes. Potential sources of error have also been identified. This has led to the development of clinical tests based on impedance plethysmography for the detection of peripheral arterial disease, venous insufficiency and venous outflow obstruction. Impedance plethysmography, using the method of venous occlusion, is presently the most commonly employed noninvasive method for the detection of deep venous thrombosis.

[1]  M. Jaffrin,et al.  Quantitative interpretation of arterial impedance plethysmographic signals , 2006, Medical and Biological Engineering and Computing.

[2]  F. Anderson,et al.  Venous occlusion plethysmography for the detection of venous thrombosis. , 1979, Medical instrumentation.

[3]  Anderson Fa,et al.  Venous occlusion plethysmography for the detection of venous thrombosis. , 1979 .

[4]  J. M. V. D. Water,et al.  Noninvasive Assessment of the Peripheral Vascular System , 1977 .

[5]  B. C. Penney,et al.  Influence of erythrocyte velocity on impedance plethysmographic measurements , 1978, Medical and Biological Engineering and Computing.

[6]  N. Patwardhan,et al.  Noninvasive detection of axillary and subclavian venous thrombosis by impedance plethysmography. , 1983, Journal of Cardiovascular Surgery.

[7]  M Gent,et al.  Diagnosis of Venous Thrombosis , 2005 .

[8]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[9]  J. Nyboer,et al.  Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study , 1950, Circulation.

[10]  K. Yamakoshi,et al.  Evaluation of the Parallel Conductor Theory for Measuring Human Limb Blood Flow by Electrical Admittance Plethysmography , 1982, IEEE Transactions on Biomedical Engineering.

[11]  Cox Rh,et al.  Evaluation of quantitative impedance plethysmography for continuous blood flow measurement. 3. Blood flow determination in vivo. , 1967 .

[12]  Herman P. Schwan,et al.  Electrical Properties of Body Tissues and Impedance Plethysmography , 1955 .

[13]  D. Geselowitz An application of electrocardiographic lead theory to impedance plethysmography. , 1971, IEEE transactions on bio-medical engineering.

[14]  Impedance plethysmography: the origin of electrical impedance changes measured in the human calf , 1980, Medical and Biological Engineering and Computing.

[15]  H. Fricke,et al.  THE ELECTRIC CONDUCTIVITY AND CAPACITY OF DISPERSE SYSTEMS , 1931 .

[16]  David S. Sumner,et al.  Hemodynamics for surgeons , 1975 .

[17]  Tatsuo Togawa,et al.  Noninvasive Measurement of Hematocrit by Electrical Admittance Plethysmography Technique , 1980, IEEE Transactions on Biomedical Engineering.

[18]  K. Yamakoshi,et al.  Admittance plethysmography for accurate measurement of human limb blood flow. , 1978, The American journal of physiology.

[19]  The Impedance Plethysmographic Sampling Field in the Human Calf , 1979, IEEE Transactions on Biomedical Engineering.