Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor.

STATEMENT OF PROBLEM Implants placed in the posterior maxilla have lower success rates compared to implants placed in other oral regions. Inadequate bone levels have been suggested as a reason for this differential success rate. PURPOSE The purpose of this study was to determine the amount and localization of functional stresses in implants and adjacent bone locations when the implants were placed in the posterior maxilla in proximity to the sinus using finite element analysis (FEA). MATERIAL AND METHODS A 3-dimensional finite element model of a maxillary posterior section of bone (Type 3) was used in this study. Different bony dimensions were generated to perform nonlinear calculations. A single-piece 4.1x10-mm screw-shaped dental implant system (ITI solid implant) was modeled and inserted into atrophic maxillary models with crestal bone heights of 4, 5, 7, 10, or 13 mm. In some models the implant penetrated the sinus floor. Cobalt-Chromium (Wiron 99) was used as the crown framework material placed onto the implant, and porcelain was used for occlusal surface of the crown. A total average occlusal force (vertical load) of 300 N was applied at the palatal cusp (150 N) and mesial fossa (150 N) of the crown. The implant and superstructure were simulated in finite element software (Pro/Engineer 2000i program). RESULTS For the porcelain superstructure for bone levels, maximum von Mises stress values were observed on the mesial fossae and palatal cusp. For the bone structure, the maximum von Mises stress values were observed in the palatal cortical bone adjacent to the implant neck. There was no stress within the spongy bone. High stresses occurred within the implants for all bone levels. CONCLUSION The maximum von Mises stresses in the implants were localized in the neck of implants for 4- and 5-mm bone levels, but for 7-, 10-, and 13-mm bone levels more even stresses occurred within the implants.

[1]  D. Benn Estimating the validity of radiographic measurements of marginal bone height changes around osseointegrated implants. , 1992, Implant dentistry.

[2]  G. Zarb,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants in anterior partially edentulous patients. , 1993, The International journal of prosthodontics.

[3]  J. Hobkirk,et al.  The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. , 1998, The Journal of prosthetic dentistry.

[4]  T Suetsugu,et al.  Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. , 1990, The Journal of oral implantology.

[5]  Chapman Rj Principles of occlusion for implant prostheses: guidelines for position, timing, and force of occlusal contacts. , 1989 .

[6]  J. Nissan,et al.  Stress distribution around maxillary implants in anatomic photoelastic models of varying geometry. Part I. , 2001, The Journal of prosthetic dentistry.

[7]  A. Garg Augmentation grafting of the maxillary sinus for placement of dental implants: anatomy, physiology, and procedures. , 1999, Implant dentistry.

[8]  W. J. O'brien,et al.  Dental Materials and Their Selection , 2002 .

[9]  H. Iplikçioğlu,et al.  Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant. , 2003, The International journal of oral & maxillofacial implants.

[10]  L Sennerby,et al.  A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. , 1992, The International journal of oral & maxillofacial implants.

[11]  Christoph Bourauel,et al.  Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. , 2001, Journal of maxillofacial surgery.

[12]  James Ra,et al.  Grafting of the maxillary sinus floor with autogenous marrow and bone. , 1980 .

[13]  Aslihan Usumez,et al.  The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study. , 2004, The Journal of prosthetic dentistry.

[14]  T D Taylor,et al.  Implant prosthodontics: current perspective and future directions. , 2000, The International journal of oral & maxillofacial implants.

[15]  B Rangert,et al.  Tilting of posterior mandibular and maxillary implants for improved prosthesis support. , 2000, The International journal of oral & maxillofacial implants.

[16]  H. Tatum Maxillary and sinus implant reconstructions. , 1986, Dental clinics of North America.

[17]  J B Brunski,et al.  Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. , 2000, The International journal of oral & maxillofacial implants.

[18]  F. Mante,et al.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. , 1998, The Journal of oral implantology.

[19]  D H DeTolla,et al.  Role of the finite element model in dental implants. , 2000, The Journal of oral implantology.

[20]  S C Bayne,et al.  3D-FEA of osseointegration percentages and patterns on implant-bone interfacial stresses. , 1997, Journal of dentistry.

[21]  R G Craig,et al.  Finite element analysis of three- and four-unit bridges. , 1989, Journal of oral rehabilitation.

[22]  U. Lekholm,et al.  Patient selection and preparation , 1985 .

[23]  S. Timoshenko,et al.  Elements Of Strength Of Materials , 1935 .

[24]  K Okimoto,et al.  Numeric approach to the biomechanical analysis of thermal effects in coated implants. , 1993, The International journal of prosthodontics.

[25]  R Puers,et al.  Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study. , 2000, Clinical oral implants research.

[26]  Misch Ce Maxillary sinus augmentation for endosteal implants: organized alternative treatment plans. , 1987 .

[27]  O. Miyakawa,et al.  Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. , 1998, The International journal of oral & maxillofacial implants.

[28]  P. Fugazzotto,et al.  Success and failure rates of cylinder implants in type IV bone. , 1993, Journal of periodontology.

[29]  S. Bayne,et al.  Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. , 1996, The Journal of prosthetic dentistry.

[30]  G D Stafford,et al.  On clinical loading of osseointegrated implants. A methodological and clinical study. , 1993, Clinical oral implants research.

[31]  U. Lekholm,et al.  Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report. , 1993, The International journal of oral & maxillofacial implants.

[32]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[33]  J. Kent,et al.  Hydroxyapatite-coated cylindrical implants in the posterior mandible: 10-year observations. , 1996, The International journal of oral & maxillofacial implants.

[34]  A. Pollack,et al.  Placement of implants in the severely atrophic posterior maxilla using localized management of the sinus floor: a preliminary study. , 2002, The International journal of oral & maxillofacial implants.

[35]  G. Liu,et al.  Application of finite element analysis in implant dentistry: a review of the literature. , 2001, The Journal of prosthetic dentistry.

[36]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[37]  G B Bruschi,et al.  Localized management of sinus floor with simultaneous implant placement: a clinical report. , 1998, The International journal of oral & maxillofacial implants.

[38]  D van Steenberghe,et al.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. , 1992, Clinical oral implants research.

[39]  V. Baelum,et al.  Implant therapy involving maxillary sinus lift in periodontally compromised patients. , 1997, Clinical oral implants research.

[40]  F. Isidor,et al.  Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. , 1996, Clinical oral implants research.

[41]  George A. Zarb,et al.  Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .

[42]  J K Lee,et al.  A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. , 1995, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[43]  N Matsumoto,et al.  Influence of bone quality on the stress distribution. An in vitro experiment. , 1997, Clinical oral implants research.

[44]  Werner Zechner,et al.  Three-dimensional finite element analysis of implant stability in the atrophic posterior maxilla: a mathematical study of the sinus floor augmentation. , 2002, Clinical oral implants research.

[45]  Ismail Yh,et al.  Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987 .

[46]  C. Misch Contemporary Implant Dentistry , 1993 .