Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm: comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography.

BACKGROUND Two-dimensional (2D) echocardiographic approaches based on geometric assumptions face the greatest limitations and inaccuracies in patients with left ventricular (LV) aneurysms. Three-dimensional (3D) echocardiographic techniques can potentially overcome these limitations; to date, however, although tested in experimental models of aneurysms, they have not been applied to a series of patients with such distortion. The purpose of this study was therefore to validate the clinical application of tomographic 3D echocardiography (3DE) by the routine transthoracic approach to determine LV chamber size and systolic function without geometric assumptions in patients with LV aneurysms. METHODS AND RESULTS In 23 patients with chronic stable LV aneurysms, LV end-systolic and end-diastolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) by tomographic 3DE were compared with results from 3D magnetic resonance tomography (3DMRT) as an independent reference as well as with the conventional techniques of single plane and biplane 2D echocardiography and biplane cineventriculography. Dynamic 3DE image data sets were obtained from a transthoracic apical view with the use of a rotating probe with acquisition gated to control for ECG and respiration (Echoscan, TomTec). Volumes were calculated from the 3D data sets by summating the volumes of multiple parallel disks. 3DE results correlated and agreed well with those by 3DMRT, with better correlation and agreement than provided by other techniques for LVEDV (3DE: r=.97, SEE=14.7 mL, SD of differences from 3DMRT=14.5 mL; other techniques: r=.84 to .93, SEE=30.7 to 41.6 mL [P<.001 versus 3DE by F test], SD of differences=31.5 to 40.7 mL [P<.001 versus 3DE by F test]). The same also pertained to LVESV (3DE: r=.97, SEE=12.4 mL, SD of differences=12.9 mL; other techniques: r=.81 to .90, SEE=24.7 to 37.2 mL [P<.001], SD of differences=27.6 to 36.8 mL [P<.005]) and LVEF (3DE: r=.74, SEE=5.6%, SD of differences=6.7%; other techniques: r=.14 to .59, SEE=9.5% to 10.1% [P<.01], SD of differences=9.5% to 12.6% [P<.05]). Compared with 3DMRT, 3DE was less time consuming and patient discomfort was less. CONCLUSIONS Tomographic 3DE is an accurate noninvasive technique for calculating LV volumes and systolic function in patients with LV aneurysm. Unlike current 2D methods, tomographic 3DE requires no geometric assumptions that limit accuracy.

[1]  G. Ertl,et al.  Serial changes in left ventricular size after acute myocardial infarction. , 1991, The American journal of cardiology.

[2]  B. Brundage,et al.  Left Ventricular Volume from Paired Biplane Two‐dimensional Echocardiography , 1979, Circulation.

[3]  D. King,et al.  Three-dimensional echocardiographic measurement of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography. , 1993, Journal of the American College of Cardiology.

[4]  R. Erbel,et al.  High-resolution two-dimensional echocardiography improves the quantification of left ventricular function. , 1992, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[5]  R. Erbel,et al.  [Determination of left ventricular volume and ejection fraction in coronary artery disease by cross-sectional echocardiography (author's transl)]. , 1980, Zeitschrift fur Kardiologie.

[6]  R. Engler,et al.  Measurement of Left Ventricular Ejection Fraction by Mechanical Cross-Sectional Echocardiography , 1979, Circulation.

[7]  R A Levine,et al.  A New Integrated System for Three-Dimensional Echocardiographic Reconstruction: Development and Validation for Ventricular Volume with Application in Human Subjects , 1993, Journal of the American College of Cardiology.

[8]  A. Weyman Cross-sectional echocardiography , 1982 .

[9]  R A Levine,et al.  Quantitative three-dimensional reconstruction of aneurysmal left ventricles. In vitro and in vivo validation. , 1995, Circulation.

[10]  C Grant,et al.  Estimation of Left Ventricular Volume by One‐Plane Cineangiography , 1967, Circulation.

[11]  A. Pearlman Measurement of left ventricular volume by three-dimensional echocardiography--present promise and potential problems. , 1993, Journal of the American College of Cardiology.

[12]  D. King,et al.  Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods. , 1995, Circulation.

[13]  H Feigenbaum,et al.  Quantitative two-dimensional echocardiographic assessment of patients undergoing left ventricular aneurysmectomy. , 1986, American heart journal.

[14]  R. Gorlin,et al.  Indications for left ventricular aneurysmectomy. , 1983, Circulation.

[15]  W Grossman,et al.  Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. , 1978, The American journal of cardiology.

[16]  P. Guéret,et al.  Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles. , 1980, American heart journal.

[17]  G T Herman,et al.  Dynamic three-dimensional reconstruction of the left ventricle from two-dimensional echocardiograms. , 1986, Journal of the American College of Cardiology.

[18]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[19]  H. Wollschlager,et al.  Transesophageal echo computer tomography: a new method for dynamic 3-D imaging of the heart (echo-CT) , 1989, [1989] Proceedings. Computers in Cardiology.

[20]  R A Levine,et al.  Three-dimensional echocardiography. In vivo validation for right ventricular volume and function. , 1993, Circulation.

[21]  R. Erbel,et al.  Tomographic left ventricular volume determination in the presence of aneurysm by three-dimensional echocardiographic imaging. I: Asymmetric model hearts. , 1996, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[22]  C. Higgins,et al.  Cine magnetic resonance imaging: tomographic analysis of left ventricular function. , 1989, Cardiology clinics.

[23]  R. O'rourke,et al.  Comparative efficacy of cross-sectional echocardiography and gated equilibrium radionuclide angiography for assessing left ventricular size and performance , 1980 .

[24]  S Effert,et al.  Echoventriculography — A Simultaneous Analysis of Two-dimensional Echocardiography and Cineventriculography , 1983, Circulation.

[25]  L. Boxt,et al.  Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging. , 1996, Heart.

[26]  F J Ten Cate,et al.  Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiography. , 1996, Circulation.

[27]  R. Erbel,et al.  [Single-plane and biplane two-dimensional echocardiographical determination of left ventricular volume II. Patients with cornary artery disease (author's transl)]. , 1981, Zeitschrift fur Kardiologie.

[28]  A. J. Dunning,et al.  Assessment of left ventricular aneurysm resectability by two-dimensional echocardiography. , 1985, The American journal of cardiology.

[29]  A. DeMaria,et al.  Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. , 1994, Journal of the American College of Cardiology.

[30]  H. Dodge,et al.  The use of biplane angiocardigraphy for the measurement of left ventricular volume in man. , 1960, American heart journal.

[31]  A. Weyman,et al.  Natural history of left ventricular size and function after acute myocardial infarction. Assessment and prediction by echocardiographic endocardial surface mapping. , 1990, Circulation.

[32]  R Gorlin,et al.  Problems in echocardiographic volume determinations: echocardiographic-angiographic correlations in the presence of absence of asynergy. , 1976, The American journal of cardiology.