Errors induced in quartz crystal mass uptake measurements by nongravimetric effects: Considerations beyond the EerNisse caution

We report frequency changes in AT-cut quartz crystals for glassy polymers subsequent to temperature and carbon dioxide pressure changes. Anomalous frequency shifts are observed for the crystal subsequent to such changes. Since, the Sauerbrey equation has been applied routinely for mass uptake measurements in glassy polymers, using the quartz crystal microbalance fitted with AT-cut quartz crystals, it is important that nongravimetric effects that impact the frequency change be well understood. In the present work, we provide a quantitative analysis of the breakdown of the Sauerbrey equation for viscoelastic materials by using the Johannsmann (Macromol Chem Phys 1999, 200, 501) treatment of the response of AT-cut crystals. Clearly, there exist significant errors in mass uptake measurements for materials deposited on AT-cut quartz crystals when precautions pertaining to film thickness and viscoelastic compliance are ignored. We show that while the early caution of EerNisse on stress effects in AT-cut quartz crystals can be important in mass uptake measurements, for polymers, the major source of error arises from viscoelastic effects in the coating. We conclude that mass uptake measurements for films of compliant materials and polymers above their glass transition cannot be performed with accuracy, using AT-cut quartz crystals if the results are not corrected for frequency shifts due to viscoelastic effects of the overlayer unless the films are extremely thin, that is, less than 100 nm. © 2006 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 44: 801–814, 2006

[1]  A. L. Smith,et al.  Principles of quartz crystal microbalance/heat conduction calorimetry: Measurement of the sorption enthalpy of hydrogen in palladium , 2005 .

[2]  Wen-li Wu,et al.  Effect of Film Thickness on the Validity of the Sauerbrey Equation for Hydrated Polyelectrolyte Films , 2004 .

[3]  M. Alcoutlabi,et al.  A comparison of concentration-glasses and temperature-hyperquenched glasses: CO2-formed glass versus temperature-formed glass , 2004 .

[4]  R. Cernosek,et al.  Characterization of epoxy resin (SU-8) film using thickness-shear mode (TSM) resonator under various conditions , 2004 .

[5]  Rodney D. Priestley,et al.  Physical aging of an epoxy subsequent to relative humidity jumps through the glass concentration , 2004 .

[6]  Hongdoo Kim,et al.  The behavior of quartz crystal microbalance in high pressure CO2 , 2004 .

[7]  M. Elbaccouch,et al.  Quartz crystal microbalance (QCM) in high-pressure carbon dioxide (CO2): experimental aspects of QCM theory and CO2 adsorption. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[8]  D. Johannsmann,et al.  Operation of the quartz crystal microbalance in liquids: derivation of the elastic compliance of a film from the ratio of bandwidth shift and frequency shift. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[9]  D. Weinkauf,et al.  Glassy polymer‐sorption phenomena measured with a quartz crystal microbalance technique , 2003 .

[10]  Gregory B. McKenna,et al.  Structural Recovery in a Model Epoxy: Comparison of Responses after Temperature and Relative Humidity Jumps , 2003 .

[11]  C. Henderson,et al.  The effect of humidity on water sorption in photoresist polymer thin films , 2003 .

[12]  Jan-Anders E. Månson,et al.  Numerical Analysis of the Dimensional Stability of Thermoplastic Composites Using a Thermoviscoelastic Approach , 2002 .

[13]  Gregory B. McKenna,et al.  Effect of chemical activity jumps on the viscoelastic behavior of an epoxy resin: Physical aging response in carbon dioxide pressure jumps , 2002 .

[14]  K. Lafdi,et al.  Effect of Thermal Property Variation on Surface Grooving , 2002 .

[15]  C. Steinem,et al.  Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors? , 2000, Angewandte Chemie.

[16]  Peter Hauptmann,et al.  The quartz crystal microbalance: mass sensitivity, viscoelasticity and acoustic amplification , 2000 .

[17]  Paul S. Ho,et al.  Thermal stress and glass transition of ultrathin polystyrene films , 2000 .

[18]  Patel,et al.  Real-time detection of organic compounds in liquid environments using polymer-coated thickness shear mode quartz resonators , 2000, Analytical chemistry.

[19]  R. Pethrick,et al.  Investigation of hydrothermal ageing of a filled rubber toughened epoxy resin using dynamic mechanical thermal analysis and dielectric spectroscopy , 2000 .

[20]  Peter Hauptmann,et al.  Gravimetric and non-gravimetric chemical quartz crystal resonators , 2000 .

[21]  D. Johannsmann,et al.  Shear moduli of polystyrene thin films determined with quartz crystal resonators in the sandwich configuration , 2000 .

[22]  C. Soles,et al.  Contributions of the nanovoid structure to the kinetics of moisture transport in epoxy resins , 2000 .

[23]  C. White,et al.  Theoretical predictions for the mechanical response of a model quartz crystal microbalance to two viscoelastic media: A thin sample layer and surrounding bath medium , 1999 .

[24]  J. P. Lucas,et al.  Hygrothermal effects of epoxy resin. Part II : Variations of glass transition temperature , 1999 .

[25]  K. F. Webb,et al.  Solubility and diffusion of carbon dioxide in polymers , 1999 .

[26]  D. Johannsmann Viscoelastic analysis of organic thin films on quartz resonators , 1999 .

[27]  C. Jeynes,et al.  Measurement of lateral stress in argon implanted thin gold films using quartz resonator techniques , 1999 .

[28]  Christopher L. Soles,et al.  Contributions of the nanovoid structure to the moisture absorption properties of epoxy resins , 1998 .

[29]  Peter Hauptmann,et al.  The non-gravimetric quartz crystal resonator response and its application for determination of polymer shear modulus , 1998 .

[30]  K. Otake,et al.  Solubility and adsorption of high pressure carbon dioxide to poly(styrene) , 1998 .

[31]  James Henry Aubert,et al.  Solubility of carbon dioxide in polymers by the quartz crystal microbalance technique , 1998 .

[32]  Fabien Josse and,et al.  Analysis of the Radial Dependence of Mass Sensitivity for Modified-Electrode Quartz Crystal Resonators , 1998 .

[33]  P. Unwin,et al.  Theory and Experiment for the Substrate Generation/Tip Collection Mode of the Scanning Electrochemical Microscope: Application as an Approach for Measuring the Diffusion Coefficient Ratio of a Redox Couple , 1998 .

[34]  T. Barbari Dual-mode free volume model for diffusion of gas molecules in glassy polymers , 1997 .

[35]  Kenji Yokoyama,et al.  Development of a chemical vapor sensor using piezoelectric quartz crystals with coated unusual lipids , 1997 .

[36]  K. Otake,et al.  Frequency change of a quartz crystal microbalance at the supercritical condition of carbon dioxide , 1994 .

[37]  G. McKenna,et al.  On the Physics Required for Prediction of Long Term Performance of Polymers and Their Composites , 1994, Journal of research of the National Institute of Standards and Technology.

[38]  E. A. Klavetter,et al.  Monitoring jet fuel thermal stability using a quartz crystal microbalance , 1993 .

[39]  Owen R. Melroy,et al.  The quartz resonator: Electrochemical applications , 1993, IBM J. Res. Dev..

[40]  Johannsmann,et al.  Viscoelastic properties of thin films probed with a quartz-crystal resonator. , 1992, Physical review. B, Condensed matter.

[41]  Michael D. Ward,et al.  Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance , 1992 .

[42]  Stephen J. Martin,et al.  Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading , 1991 .

[43]  M. Ward,et al.  Radial Mass Sensitivity of the Quartz Crystal Microbalance in Liquid Media , 1991 .

[44]  W. O'grady,et al.  Measurement of hydrogen uptake by palladium using a quartz crystal microbalance , 1990 .

[45]  D. Buttry,et al.  Electrochemical applications of the quartz crystal microbalance , 1989 .

[46]  N. Hadjichristidis,et al.  A study of the linear viscoelastic properties of cyclic polystyrenes using creep and recovery measurements , 1989 .

[47]  Mark R. Deakin,et al.  Prussian Blue coated quartz crystal microbalance as a detector for electroinactive cations in aqueous solution , 1989 .

[48]  J. W. Barlow,et al.  Polymer crystallization induced by sorption of CO2 gas , 1985 .

[49]  W. Sachse,et al.  Effects of high‐pressure CO2 on the glass transition temperature and mechanical properties of polystyrene , 1982 .

[50]  E. P. Eernisse Extension of the double resonator technique , 1973 .

[51]  E. P. EerNisse,et al.  Simultaneous Thin‐Film Stress and Mass‐Change Measurements Using Quartz Resonators , 1972 .

[52]  K. Behrndt Long-Term Operation of Crystal Oscillators in Thin-Film Deposition , 1971 .

[53]  D. Plazek Temperature dependence of the viscoelastic behavior of polystyrene. , 1965 .

[54]  A. J. Kovacs,et al.  Transition vitreuse dans les polymères amorphes. Etude phénoménologique , 1964 .

[55]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[56]  M. Alcoutlabi,et al.  Real-time monitoring of mass change during the structural evolution of an epoxy glass subsequent to relative humidity jumps through the glass transition , 2004 .

[57]  A. A. Vives Piezoelectric transducers and applications , 2004 .

[58]  C. Panayiotou,et al.  Measurement of HCFC-22 and HFC-152a sorption by polymers using a quartz crystal microbalance , 2001 .

[59]  Harry O. Finklea,et al.  Detection of Nonpolar Vapors on Quartz Crystal Microbalances with Ni(SCN)2(4-picoline)4 Coatings , 1999 .

[60]  D. Johannsmann,et al.  Viscoelastic properties of thin films studied with quartz crystal resonators , 1997 .

[61]  E. P. Eernisse,et al.  Survey of quartz bulk resonator sensor technologies , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[62]  Alan Townshend,et al.  Applications of piezoelectric quartz crystal microbalances , 1987 .

[63]  E. P. Eernisse Chapter 4 - Stress Effects in Quartz Crystal Microbalances , 1984 .

[64]  L. Struik Physical aging in amorphous polymers and other materials , 1978 .

[65]  Chih−shun Lu,et al.  Mass determination with piezoelectric quartz crystal resonators , 1975 .

[66]  D. Denison Linearity of a Heavily Loaded Quartz Crystal Microbalance , 1973 .

[67]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .